Plan Review Details - Permit 13100678
Plan Review Stops For Permit 13100678
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-12-12 Cont ID  
Sent By skennedy Date 2013-12-12 Time 15:08 Rev Time 0.00
Received By skennedy Date 2013-12-12 Time 15:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-11-02 Cont ID  
Sent By jwitmer Date 2013-11-02 Time 08:26 Rev Time 0.00
Received By jwitmer Date 2013-11-02 Time 08:04 Sent To  
Notes
2013-11-02 08:26:37BUILDING PLAN REVIEW
 PERMIT: 13100678
 ADD: 4700 N CONGRESS # 101-106
 CONT: ANDERSON-MOORE
 TEL: (561)662-1819
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE,
 1ST REVIEW
 DATE: SAT NOV. 02/ 2013
 ACTION: DENIED
  
 1) SHEET A1 WIND DESIGN CRITERIA IS INDICATED AS A B
 EXPOSURE PLEASE REVIEW 2010 FBC-B BUILDING 1609.4.2
 SURFACE ROUGHNESS CATEGORIES. SURFACE ROUGHNESS C. OPEN
 TERRAIN WITH SCATTERED OBSTRUCTIONS HAVING HEIGHTS
 GENERALLY LESS THAN 30 FEET (9144 MM). THIS CATEGORY
 INCLUDES FLAT OPEN COUNTRY AND GRASSLANDS.THIS SURFACE
 ROUGHNESS SHALL ALSO APPLY TO ANY BUILDING LOCATED
 WITHIN SURFACE ROUGHNESS B-TYPE TERRAIN WHERE THE
 BUILDING IS WITHIN 100 FEET HORIZONTALLY IN ANY
 DIRECTION OF OPEN AREAS OF SURFACE ROUGHNESS C OR
 D-TYPE TERRAIN THAT EXTENDS MORE THAN 600 FEET (182.9
 M) AND WIDTH GREATER THAN 150 FEET IN THE UPWIND
 DIRECTION. SHORT-TERM (LESS THAN TWO YEAR) CHANGES IN
 THE PRE-EXISTING TERRAIN EXPOSURE, FOR THE PURPOSES OF
 DEVELOPMENT, SHALL NOT BE CONSIDERED SURFACE ROUGHNESS
 C. PLEASE UPDATE EXPOSURE CATEGORY AND ASSOCIATED
 PRESSURES.
  
 2) FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 3) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-12-12 Cont ID  
Sent By skennedy Date 2013-12-12 Time 15:08 Rev Time 0.00
Received By skennedy Date 2013-12-12 Time 15:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-12-04 Cont ID  
Sent By skennedy Date 2013-12-04 Time 16:00 Rev Time 0.00
Received By skennedy Date 2013-12-04 Time 16:00 Sent To  
Notes
2013-12-04 16:14:42PLEASE ADDRESS THE FOLLOWING ISSUES:
 1) PROVIDE A TITLE BLOCK FOR THE ENGINEER OF RECORD
 CONSISTANT WITHT THE REQUIREMENTS OF FAC 61G15-23.002.
 EG: PRINTED NAME, LICENSE NUMBER, CERTIFICATE OF
 AUTHORIZATION FOR ENGINEERING....ETC.
 2) PLEASE SPECIFY THE SCOPE OF WORK TO BE PERFORMED,
 IE: LANDLORD VS. TENANT RESPONSIBILITIES.
 3) PLAN MAY NOT CONTAIN THE PHRASE " PRELIMINARY - NOT
 FOR CONSTRUCTION
  
 STEVEN KENNEDY
 561 805 6710
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-11-21 Cont ID  
Sent By wjolin Date 2013-11-21 Time 13:16 Rev Time 0.00
Received By wjolin Date 2013-11-21 Time 12:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-12-12 Cont ID  
Sent By skennedy Date 2013-12-12 Time 15:08 Rev Time 0.00
Received By skennedy Date 2013-12-12 Time 14:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-12-04 Cont ID  
Sent By skennedy Date 2013-12-04 Time 16:00 Rev Time 0.00
Received By skennedy Date 2013-10-21 Time 16:08 Sent To  
Notes
2013-10-21 16:09:21INCOMING SENT TO B14, JW

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-12-12 Cont ID  
Sent By skennedy Date 2013-12-12 Time 15:08 Rev Time 0.00
Received By skennedy Date 2013-12-12 Time 15:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-11-19 Cont ID  
Sent By hmoser Date 2013-11-19 Time 13:51 Rev Time 0.00
Received By hmoser Date 2013-11-19 Time 13:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-12-04 Cont ID  
Sent By skennedy Date 2013-12-04 Time 15:59 Rev Time 0.00
Received By skennedy Date 2013-12-04 Time 15:59 Sent To  
Notes
2013-12-04 16:13:21 
  

Review Stop Z ZONING
Rev No 1 Status N Date 2013-10-30 Cont ID  
Sent By ajones Date 2013-10-30 Time 15:04 Rev Time 0.00
Received By ajones Date 2013-10-30 Time 15:04 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved