Plan Review Stops For Permit 13100665 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2013-11-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-11-19 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-11-19 |
Time |
12:31 |
Sent To |
|
|
Notes |
2013-11-19 16:38:48 | BUILDING PROVISO: | | COMPLY WITH 2020 FBC-B 713.6 | | FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL | | REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE | | EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY | | HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE | | ANY DECORATIVE CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: ?FIRE | | AND SMOKE BARRIER ? PROTECT ALL OPENINGS.? |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-01-02 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2014-01-02 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2014-01-02 |
Time |
08:38 |
Sent To |
I |
|
Notes |
2014-01-02 09:20:39 | THOUGH THE METER ROOM DIMENSIONS ARE NOT PROVIDED, IT | | IS UNDERSTOOD THAT THE ADDITION OF THE NEW APPARATUS | | SHALL NOT ENCROACH ON THE CODE REQUIRED WORKING SPACE | | OF ANY OTHER EQUIPMENT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-12-11 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2013-12-11 |
Time |
19:43 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2013-12-11 |
Time |
17:11 |
Sent To |
M |
|
Notes |
2013-12-11 20:07:45 | THE FOLLOWING ITEMS SHALL BE ADDRESSED AND CORRECTED | | ACCORDINGLY: | | 1. PAGE E1.0 "SPECIAL PURPOSE OUTLETS" THERE IS A | | CONFLICT ON THE HEATER NOTES. THE NOTES CALL FOR POWER | | SOURCE FROM PANEL PR. THE RISER DIAGRAM REFLECTS TWO | | PANELS, A P AND A R, BUT NO PR. | | 2. THE PANEL SCHEDULES FOR EITHER PANELS P OR R DO NOT | | REFLECT ANY HEATER LOAD OR HVAC. | | 3. THE ONLY OTHER HEATER IS THE EWH FED FROM THE MDP. | | 4. DUE TO ALL THE RE-ARRANGEMENT OF LOADS ON THE | | VARIOUS PANELBOARDS, INDIVIDUAL LOAD CALCS AND A PANEL | | SCHEDULE SHALL BE PROVIDED FOR EACH PANEL. | | 5. THE EXISTING RISER MENTIONS "RTU1" W/A 90A | | DISCONNECT. THIS RTU1 DOES NOT APPEAR AGAIN AND NO | | MENTION OF ITS REMOVAL IS MADE. | | 6. THE TENANT RISER DIAGRAM REFLECTS AN "EXISTING RTU" | | W/A 70A DISCONNECT AND A "NEW RTU" W/A 60A DISCONNECT. | | AGAIN THERE IS A CONFLICT. | | 7. IN AREAS OTHER THAN THOSE DIRECTLY ASSOCIATED WITH | | PATIENT CARE OR THOSE AREAS REQUIRED FOR HEALTH & LIFE | | SAFETY, COMPLIANCE W/THE FBC-ENERGY CONSERVATION IS | | REQUIRED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2013-11-22 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-11-22 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-11-22 |
Time |
12:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-01-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-01-02 |
Time |
18:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-12-30 |
Time |
11:39 |
Sent To |
|
|
Notes |
2014-01-02 09:21:03 | SH | 2013-12-31 11:41:31 | SENT TO M ALBARAN |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-12-14 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-12-14 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-10-21 |
Time |
16:17 |
Sent To |
|
|
Notes |
2013-10-21 16:18:08 | INCOMING SENT TO C-34. JW |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2013-12-14 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-12-14 |
Time |
11:44 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-12-14 |
Time |
11:08 |
Sent To |
|
|
Notes |
2013-12-14 11:42:37 | PASS PROVISO | | 1) PROVIDE A ENGINEER DETAIL ON HOW THE CONDENSER IS | | ANCHORED TO | | THE ROOF PER SECTION 301.12 WIND RESISTANCE 2010 FBC | | (M) | | AT FIRST INSPECTION. | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | 2013-12-12 08:18:35 | RETURNED FILE TO BIN C34 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2013-11-13 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-11-13 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-11-12 |
Time |
13:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2013-10-30 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2013-10-30 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2013-10-30 |
Time |
14:46 |
Sent To |
|
|
Notes |
|
|