Plan Review Details - Permit 13100452
Plan Review Stops For Permit 13100452
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-12-20 Cont ID  
Sent By shill Date 2013-12-20 Time 10:07 Rev Time 0.00
Received By shill Date 2013-12-20 Time 10:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-11-16 Cont ID  
Sent By shill Date 2013-11-16 Time 08:55 Rev Time 0.00
Received By shill Date 2013-11-16 Time 08:55 Sent To Z
Notes
2013-11-16 08:56:16****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 FROM PREVIOUS LIST:
  
 1. PROVIDE A VERIFIABLE CONTRACT FOR THIS JOB. VALUE IS
 TO INCLUDE LABOR, MATERIALS, AND ENGINEERING, EVEN IF
 THE MATERIALS ARE SUPPLIED BY OTHERS, FBC 109.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-10-28 Cont ID  
Sent By shill Date 2013-10-28 Time 17:31 Rev Time 0.00
Received By shill Date 2013-10-28 Time 17:30 Sent To  
Notes
2013-10-28 17:38:45****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. DESIGN PROFESSIONAL FOR THE RENOVATION SPECIFIES
 BUILDING DESIGN PRESSURE AS 170; NOT CLEAR WHETHER THIS
 APPLIES TO SIGNAGE. SIGN ENGINEERING TO BE REVIEWED BY
 DESIGNER OF RECORD, FBC 1609, OR PROVIDE CLARIFICATION
 LETTER FROM HARTLEY PURDY ARCHITCTURE, OR REVISE
 ENGINEERING DESIGN TO 170MPH EXPOSURE C MINIMUM.
  
 2. PROPOSED FASTENING NOT CLEAR. THE SECTION ON THE
 LEFT SIDE OF THE PLAN SHOWS (5) 1/4" X 2" TPACONS; 5
 DOES NOT APPEAR TO BE ENOUGH FASTENERS FOR A 42" X 48"
 M-ARCH SIGN. INSTALL INSTRUCTIONS STATE LAG SCREWS AND
 WASHERS WILL BE USED FOR INSTALLATION; NOT CLEAR FOR
 WHICH OF THE SIGNS THIS APPLIES AND MINIMUM NUMBER OF
 FASTENERS NOT SPECIFIED.
  
 3. PROVIDE A VERIFIABLE CONTRACT FOR THIS JOB. VALUE IS
 TO INCLUDE LABOR, MATERIALS, AND ENGINEERING, EVEN IF
 THE MATERIALS ARE SUPPLIED BY OTHERS, FBC 109.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-11-27 Cont ID  
Sent By skennedy Date 2013-11-27 Time 14:08 Rev Time 0.00
Received By skennedy Date 2013-11-27 Time 14:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-10-28 Cont ID  
Sent By albarran Date 2013-10-28 Time 12:50 Rev Time 0.00
Received By albarran Date 2013-10-28 Time 12:44 Sent To B
Notes
2013-10-28 12:51:43PLACED BACK IN BIN FOR FURTHER REVIEW

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-12-20 Cont ID  
Sent By shill Date 2013-12-20 Time 10:07 Rev Time 0.00
Received By shill Date 2013-12-04 Time 13:14 Sent To  
Notes
2013-12-04 13:15:15SUBMITTAL SENT TO SAMANTHA'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-12-02 Cont ID  
Sent By shill Date 2013-12-02 Time 18:57 Rev Time 0.00
Received By shill Date 2013-11-16 Time 08:56 Sent To  
Notes
2013-11-16 08:56:5511/16 TO ZONING (NEW SHEETS)
  
2013-11-06 09:02:47BLDG <5000 ROUTED TO S HILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-10-28 Cont ID  
Sent By shill Date 2013-10-28 Time 17:38 Rev Time 0.00
Received By shill Date 2013-10-15 Time 11:27 Sent To  
Notes
2013-10-15 11:27:26ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2013-11-19 Cont ID  
Sent By llouie Date 2013-11-19 Time 10:19 Rev Time 0.00
Received By llouie Date 2013-11-19 Time 10:18 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2013-10-18 Cont ID  
Sent By llouie Date 2013-10-18 Time 16:39 Rev Time 0.00
Received By llouie Date 2013-10-18 Time 16:39 Sent To E
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved