Plan Review Stops For Permit 13100403 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-04-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-04-09 |
Time |
12:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-04-09 |
Time |
12:54 |
Sent To |
FIRE |
|
Notes |
2014-04-09 12:56:53 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FROM PREVIOUS LIST: | | | | 4. ILLUMINATION NOT SHOWN BUT IS REQUIRED, FBC 1006. | | | | IMPACT FEES MAY BE DUE TO PALM BEACH COUNTY. THE PLANS | | ARE TO BE STAMPED AND RECEIPT PROVIDED (IF FEES WERE | | DUE AND PAID). 233-5025 FOR MORE INFORMATION. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-11-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-11-21 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-11-21 |
Time |
11:27 |
Sent To |
Z |
|
Notes |
2013-11-21 13:02:54 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. DESIGNER TO ELECT A METHOD OF COMPLIANCE, FBC 2010 | | EXISTING BUILDING 101.5. AS DESIGNER HAS NOT ELECTED A | | METHOD, COMMENTS WILL REFER TO THE APPLICABLE FBC 2010 | | BUILDING REQUIREMENTS (RATHER THAN FBC 2010 EXISTING | | BUILDING). NOTE THAT NOT ENOUGH INFORMATION WAS | | PROVIDED TO GIVE A COMPLETE COMMENT LIST. | | | | 2. PROVIDE A BUILDING SUMMARY ? SIZE, BUILDING TYPE, | | OCCUPANCY CLASSIFICATION (FBC CHAPTER 5, 6, 3). | | | | 3. INCLUDE OCCUPANCY CLASSIFICATION (FBC CHAPTER 3) AND | | OCCUPANT LOAD OF PROPOSED SPACE, (FBC CHAPTER 10, FBC | | 2010 ACCESSIBILITY 201.1.1. IF THIS IS TO BE DESIGNED | | TO BE EXEMPT FROM VERTICAL ACCESSIBILITY REQUIREMENTS, | | CLEARLY INDICATE ON THE PLAN WHICH EXEMPTION THIS FALLS | | UNDER. | | | | 4. ILLUMINATION NOT SHOWN BUT IS REQUIRED, FBC 1006. | | | | 5. CEILING HEIGHT TO COMPLY WITH FBC 1003.2. | | | | 6. BARRIER REQUIRED, FBC 1003.3.1. | | | | 7. PROPOSED IMPROVEMENT IS A MEZZANINE, PROVIDE | | INFORMATION SHOWING COMPLIANCE WITH FBC 505. | | | | 8. STAIR INFORMATION FBC 1009 NOT SHOWN. | | | | 9. HANDRAILS NOT SHOWN FBC 1009.12. | | | | 10. PROVIDE A DETAIL WHICH SHOWS COMPLIANCE WITH FBC | | 1013.3. | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2014-04-18 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-04-18 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-04-18 |
Time |
14:47 |
Sent To |
PC |
|
Notes |
2014-04-18 14:55:43 | THIS PLAN WAS REVIEWED BY PETER LEDUC, FIRE MARSHAL, | | WITH THE FOLLOWING COMMENT. | | | | THE PREVIOUS COMMENTS OF FIRE PREVENTION WERE NOT | | ADDRESSED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2013-11-02 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-11-02 |
Time |
12:54 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-11-02 |
Time |
12:35 |
Sent To |
B |
|
Notes |
2013-11-02 12:54:31 | 1717 EDGAR STREET | | PERMIT #13100403 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | HEADROOM: THE BAR JOISTS ABOVE THE MEZZANINE ARE | | LOCATED WITHIN 7'-6" OF THE FLOOR DECK. | | | | STAIR HANDRAILS& GUARDRAILS: GUARDS, AT LEAST 42-INCHES | | TALL, SHALL BE PROVIDED AT THE OPEN SIDES OF MEANS OF | | EGRESS (STAIRS, MEZZANINE, ETC.) THAT EXCEED 30-INCHES | | ABOVE THE FLOOR. OPEN GUARDS SHALL PROHIBIT THE PASSAGE | | OF A 4-INCH DIAMETER SPHERE UP TO A HEIGHT OF | | 34-INCHES. THE TRIANGULAR OPENINGS FORMED BY THE RISER, | | TREAD AND BOTTOM ELEMENT OF THE GUARDRAIL SHALL | | PROHIBIT THE PASSAGE OF A 6-INCH DIAMETER SPHERE. | | HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIR. | | HANDRAILS SHALL BE LOCATED NOT LESS THAN 34 INCHES AND | | NOT MORE THAN 38 INCHES ABOVE THE SURFACE OF THE TREAD, | | MEASURED VERTICALLY TO THE TOP OF THE RAIL FROM THE | | LEADING EDGE OF THE TREAD. HANDRAIL ENDS SHALL BE | | RETURNED TO THE WALL OR FLOOR OR SHALL TERMINATE AT | | NEWEL POSTS. HANDRAIL CROSS SECTION SHALL HAVE A | | DIAMETER OF NOT LESS THAN 1.25 INCHES AND NOT MORE THAN | | 2 INCHES. | | | | STAIR RISERS: INDICATE THE HEIGHT OF THE STAIR RISERS. | | | | INDICATE THE LOCATIONS OF MEZZANINE LIGHTING. IS | | LIGHTING TO BE PROVIDED TO ILLUMINATE THE AREA BELOW | | THE MEZZANINE? | | | | STRUCTURES WITH LIGHT FRAME FLOOR CONSTRUCTION SHALL BE | | IDENTIFIED WITH A SIGN AFFIXED TO THE BUILDING. THE | | SIGN SHALL FEATURE A MALTESE CROSS 8-INCHES WIDE AND | | 8-INCHES TALL AND BE OF A BRIGHT RED REFLECTIVE COLOR | | AND BEAR THE LETTER F DESIGNATION PER FLORIDA STATUTE | | 633.027 AND FLORIDA ADMINISTRATIVE CODE 69A-60.0081. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-04-18 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2014-04-18 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2014-03-28 |
Time |
07:17 |
Sent To |
PC |
|
Notes |
2014-04-09 12:58:23 | 4/9 TO FIRE | | | 2014-03-31 07:17:29 | SENT TO S HILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-11-26 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2013-11-26 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
llouie |
Date |
2013-10-11 |
Time |
10:12 |
Sent To |
|
|
Notes |
2013-11-22 13:29:55 | 11/22 TO ZONING | | | 2013-10-30 11:08:59 | 10/30 TO FIRE | | | 2013-10-12 10:13:14 | SENT TO BUILDING UNDER $5000 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2014-04-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2014-04-09 |
Time |
12:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2014-04-09 |
Time |
12:57 |
Sent To |
|
|
Notes |
2014-04-09 12:58:10 | IMPACT FEE ASSESSMENT REQUIRED - CONTACT 561-233-5025 | | FOR MORE INFORMATION | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2013-11-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-11-21 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-11-21 |
Time |
11:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2013-11-26 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2013-11-26 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
llouie |
Date |
2013-11-26 |
Time |
13:51 |
Sent To |
I |
|
Notes |
2013-11-26 13:51:08 | ZONING REVIEW NOT REQUIRED. PROPOSED MEZZANINE IS LESS | | THAN 1,000 SQ. FT. |
|
|