Plan Review Details - Permit 13100366
Plan Review Stops For Permit 13100366
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-11-21 Cont ID  
Sent By jwitmer Date 2013-11-21 Time 13:17 Rev Time 0.00
Received By jwitmer Date 2013-11-21 Time 12:30 Sent To  
Notes
2013-11-15 14:10:17JW STAMP ONLY

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-10-23 Cont ID  
Sent By jwitmer Date 2013-10-23 Time 06:28 Rev Time 0.00
Received By jwitmer Date 2013-10-23 Time 06:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-12-03 Cont ID  
Sent By albarran Date 2013-12-03 Time 10:13 Rev Time 0.00
Received By albarran Date 2013-12-03 Time 10:02 Sent To I
Notes
2013-12-03 10:14:23CORRECTIONS SUBMITTED AS REQUESTED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-11-06 Cont ID  
Sent By albarran Date 2013-11-06 Time 13:30 Rev Time 0.00
Received By albarran Date 2013-11-06 Time 13:06 Sent To I
Notes
2013-11-06 13:36:13THE FOLLOWING ITEMS WERE NOTED AND NEED CORRECTION FOR
 THE ELECTRICAL PLANS REVIEW.
 1. PAGE CVR MAKES REFERENCE TO NEC 2005 RATHER THAN THE
 2008 NOW IN EFFECT.
 2. THE LIGHTING CONTROL DIAGRAM DOES NOT MEET
 FBC-ENERGY CONSERVATION. NO OVER RIDE PROVISIONS
 INDICATED.
 3. THOUGH THE RISER DIAGRAMS SHOW THE TRANSFORMER, IT
 DOES NOT APPEAR ON THE FLOOR PLANS
 4. THE ELECTRICAL RISER DIAGRAM SHOWN ON PAGE E@ DOES
 NOT MATCH THE ON SHOWN ON PAGE E3.
  
 PLEASE CORRECT THE ABOVE MENTIONED DEFICIENCIES AND
 RESUBMIT FOR REVIEW.
  
 SENT TO SH DESK

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-11-19 Cont ID  
Sent By scaldero Date 2013-11-19 Time 15:23 Rev Time 0.00
Received By scaldero Date 2013-11-19 Time 15:23 Sent To  
Notes
2013-11-15 14:11:46TO STAMP ONLY PG CVR

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-10-23 Cont ID  
Sent By scaldero Date 2013-10-23 Time 16:45 Rev Time 0.00
Received By scaldero Date 2013-10-23 Time 16:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-12-03 Cont ID  
Sent By skennedy Date 2013-12-03 Time 11:03 Rev Time 0.00
Received By skennedy Date 2013-11-15 Time 14:12 Sent To  
Notes
2013-12-03 10:14:52SENT TO SK FOR PROCESSING
2013-11-15 16:28:59B11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-11-06 Cont ID  
Sent By shill Date 2013-11-06 Time 17:35 Rev Time 0.00
Received By shill Date 2013-10-10 Time 11:29 Sent To  
Notes
2013-10-12 11:30:59B19

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-10-31 Cont ID  
Sent By mricard Date 2013-10-31 Time 13:33 Rev Time 0.00
Received By mricard Date 2013-10-31 Time 13:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-10-25 Cont ID  
Sent By mricard Date 2013-10-25 Time 08:13 Rev Time 0.00
Received By mricard Date 2013-10-25 Time 08:06 Sent To  
Notes
2013-10-25 08:21:02PROVIDE ENERGY CALC,S FOR THE SPACE IN QUESTION.
 INCLUDE CONDENSATE AND HANGING DETAILS