Plan Review Details - Permit 13100088
Plan Review Stops For Permit 13100088
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-10-26 Cont ID  
Sent By jwitmer Date 2013-10-26 Time 07:56 Rev Time 0.00
Received By jwitmer Date 2013-10-26 Time 07:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-10-18 Cont ID  
Sent By jwitmer Date 2013-10-18 Time 06:28 Rev Time 0.00
Received By jwitmer Date 2013-10-18 Time 06:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-10-18 Cont ID  
Sent By dharvey Date 2013-10-18 Time 08:08 Rev Time 0.00
Received By dharvey Date 2013-10-18 Time 06:33 Sent To  
Notes
2013-10-18 08:08:26TO J WITMER

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-10-07 Cont ID  
Sent By pleduc Date 2013-10-07 Time 15:36 Rev Time 0.00
Received By pleduc Date 2013-10-07 Time 15:18 Sent To  
Notes
2013-10-07 15:36:14THIS PLAN IS APPROVED WITH COMMENTS.
  
 1. ON PAGE A -5 UNDER SECTION 2, FINISHES, IN THE
 COMMENTS IT STATES " ALL INTERIOR WALL AND CEILING
 FINISHES TO HAVE A MIN CLASS "C" FLAME SPREAD
 CLASSIFICATION. ACCORDING TO NFPA 101 FL ED., CHAPTER
 39; 39..3.3.2.1- INTERIOR WALL AND CEILING FINISH
 MATERILAS COMPLYING WITH SECTION 10.2 SHALL BE CLASS A
 OR B IN EXITS AND IN EXIT ACCESS CORRIDORS.
  
 ACCORDING TO THE PLAN THERE ARE 4 EXIT ACCESS CORRIDORS
 THAT MEET THIS REQUIREMENT. THESE CORRIDORS SHALL HAVE
 A WALL FINISH OF CLASS A OR B. A MATERIAL LIST AND/OR
 PRODUCT SHEET SHALL BE AVAILABLE FOR THE FIRE INSPECTOR
 AT ANY TIME IT IS REQUESTED.
  
 2. EMERGENCY LIGHING IS REQUIRED UNDER NFPA 101 FL ED.,
 CHAPTER 39, 39.2.9.1. PLEASE PROVIDE FOR EMERGENCY
 LIGHTING AS REQUIRED. DUAL SERVICE EXIT/EMERGENCY
 LIGHTS ARE ACCEPTABLE WHERE APPLICABLE. ADDITIONAL
 LIGHTS MAY BE NEEDED ALONG EXIT ACCESS CORRIDORS.
  
 3. AN EXIT LIGHT IS NOT INDICATED AT THE BREAK ROOM
 REAR DOOR. IF ONE IS NOT EXISTING, PLEASE INSTALL ONE
 AT THAT LOCATION. A FIRE INSPECTOR SHALL INSPECT AND
 VERIFY ON INSPECTION.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-10-26 Cont ID  
Sent By jwitmer Date 2013-10-26 Time 07:56 Rev Time 0.00
Received By jwitmer Date 2013-10-25 Time 14:56 Sent To  
Notes
2013-10-25 14:57:37SENT TO JW DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-10-18 Cont ID  
Sent By jwitmer Date 2013-10-18 Time 08:37 Rev Time 0.00
Received By jwitmer Date 2013-10-02 Time 18:21 Sent To  
Notes
2013-10-02 18:22:02INCOMING SENT TO C-30 BOX. JW

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-10-26 Cont ID  
Sent By jwitmer Date 2013-10-26 Time 07:56 Rev Time 0.00
Received By jwitmer Date 2013-10-26 Time 07:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-10-17 Cont ID  
Sent By hmoser Date 2013-10-17 Time 15:13 Rev Time 0.00
Received By hmoser Date 2013-10-17 Time 15:08 Sent To  
Notes
2013-10-17 15:13:28PLANS DENIED
 PROVIDE DUCT AND GRILL SIZE ON THE PLANS.
 PER SECTION 107 FBC 2010
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-10-17 Cont ID  
Sent By lwagner Date 2013-10-17 Time 16:42 Rev Time 0.00
Received By lwagner Date 2013-10-17 Time 15:59 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2013-10-09 Cont ID  
Sent By ajones Date 2013-10-09 Time 13:13 Rev Time 0.00
Received By ajones Date 2013-10-09 Time 13:13 Sent To  
Notes
***NONE***