Plan Review Details - Permit 13090980
Plan Review Stops For Permit 13090980
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-11-04 Cont ID  
Sent By jwitmer Date 2013-11-04 Time 15:24 Rev Time 0.00
Received By jwitmer Date 2013-11-04 Time 15:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-10-19 Cont ID  
Sent By jwitmer Date 2013-10-19 Time 08:14 Rev Time 0.00
Received By jwitmer Date 2013-10-19 Time 07:00 Sent To  
Notes
2013-10-19 08:13:59BUILDING PLAN REVIEW
 PERMIT: 13090980
 ADD: 700 S ROSEMARY # 218
 CONT: DAVIS CONSTRUCTION
 TEL: (561) 848-0577
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SATURDAY OCT. 19/2013
 ACTION: DENIED
  
 1) SHEET A1 DETAILS, THE LOWER LEFT SMALL DETAIL
 INDICATES THE STEEL STUD AT 16 GAUGE, THE UPPER RIGHT
 LARGER DETAIL INDICATES 20 GAUGE STEEL STUDS AND THE
 LOWER RIGHT ALSO INDICATES THE USE OF 20 GAUGE STEEL
 STUDS. PLEASE CORRECT THE DISCREPANCY, PLEASE PROVIDE
 IF 20 GAUGE STEEL STUDS TYPE STRUCTURAL 33 MILLS
 THICKNESS OR 20 GAUGE DRYWALL 30 MILLS THICK. 107.2.1.3
 ADDITIONAL INFORMATION REQUIRED.
  
 2) THE WAY THE LOWER RIGHT DETAIL IS DRAWN THE 1/2"
 ALLTHREAD IS PENETRATES A HORIZONTAL 2X6 SYP AND A NUT
 ON THE BOTTOM. THE WAY IT IS DETAILED IT APPEARS TO BE
 BLOCKING BETWEEN THE 3 5/8" STEEL STUDS JUST AS
 DEPICTED ON THE VERTICAL FRAMING AS BACKING. IT WOULD
 APPEAR THIS DETAIL NEEDS TO CLARIFY IF THE 2-X6 ARE
 FRAMING MEMBERS (PURLINS) THAT WOULD BE BELOW THE
 HORIZONTAL STEEL STUDS CARRYING THE STEEL STUDS?
 107.2.1.3. ADDITIONAL INFORMATION IS REQUIRED.
  
 3) PLEASE PROVIDE IN WHICH WAY THE BAR JOIST ARE
 RUNNING, IT WOULD APPEAR THEY ARE PARRALLEL TO THE
 HORIZONTAL 3 5/8 INCH STEEL STUDS, ALSO PROVIDE AT WHAT
 SPACING THE BAR JOIST ARE APART, ASSUMED 5'-0" O.C. THE
 PLANS ARE NOT CLEAR AS TO IF THE WIDTH OF THE DROPPED
 SOFFIT, IT APPEARS TO BE APPROXIMATELY 16'-0" IN DEPTH,
 WOULD THERE BE 5 VERTICAL 1/2" ALLTHREADS FASTENED
 THROUGH THE SAME BAR JOIST? HAS THE ADDITIONAL LOADING
 BEEN FIGURED INTO THE CARRYING CAPACITY OF THE BAR
 JOIST?
  
 4) THE BOTTOM RIGHT DETAIL PLEASE PROVIDE AS TO THE
 FINISH MATERIALS TO BE APPLIED TO THE DROPPED SOFFIT,
 THERE APPEARS TO BE TWO DIFFERNT TYPE OF MATERIALS,
 TYPE NOR THICKNESS HAS NOT BEEN ESTABLISHED ON THE
 PLANS. 107.2.1.3 ADITIONAL INFORMATION IS REQUIRED.
 ALSO REFER TO 2010 FBC-B 802.11.2. SET OUT
 CONSTRUCTION.
  
 2010 FBC-B 803.11.2 SET-OUT CONSTRUCTION.
 WHERE WALLS AND CEILINGS ARE REQUIRED TO BE OF
 FIRE-RESISTANCE-RATED OR NONCOMBUSTIBLE CONSTRUCTION
 AND WALLS ARE SET OUT OR CEILINGS ARE DROPPED DISTANCES
 GREATER THAN SPECIFIED IN SECTION 803.11.1, CLASS A
 FINISH MATERIALS, IN ACCORDANCE WITH SECTION 803.1.1 OR
 803.1.2, SHALL BE USED EXCEPT WHERE INTERIOR FINISH
 MATERIALS ARE PROTECTED ON BOTH SIDES BY AN AUTOMATIC
 SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1
 OR 903.3.1.2, OR ATTACHED TO NONCOMBUSTIBLE BACKING OR
 FURRING STRIPS INSTALLED AS SPECIFIED IN SECTION
 803.11.1. THE HANGERS AND ASSEMBLY MEMBERS OF SUCH
 DROPPED CEILINGS THAT ARE BELOW THE MAIN CEILING LINE
 SHALL BE OF NONCOMBUSTIBLE MATERIALS, EXCEPT THAT IN
 TYPES III AND V CONSTRUCTION, FIRE-RETARDANT-TREATED
 WOOD SHALL BE PERMITTED. THE CONSTRUCTION OF EACH
 SET-OUT WALL SHALL BE OF FIRE-RESISTANCE-RATED
 CONSTRUCTION AS REQUIRED ELSEWHERE IN THIS CODE.
  
 PLEASE PROVIDE AT WHAT PORTION OF THIS SOFFIT AND
 DROPPED CEILING ARE EXISTING AND WHAT PORTION IS TO BE
 CONSIDERED NEW WORK, THE VALUE OF THE WORK IS DECLARED
 AT $2499.00 DOLLARS, THIS VALUE MAY APPEAR TO BE LOW,
 OWNERS SIGNATURE AS WELL AS CONTRACTOR MAY BE REQUIRED
 AND NOTIRIZED.
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-10-25 Cont ID  
Sent By skennedy Date 2013-10-25 Time 15:18 Rev Time 0.00
Received By skennedy Date 2013-10-25 Time 15:18 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-10-11 Cont ID  
Sent By scaldero Date 2013-10-11 Time 14:09 Rev Time 0.00
Received By scaldero Date 2013-10-11 Time 14:09 Sent To  
Notes
2013-10-11 14:11:28PERMIT # 13090980
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION
 SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND
 RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION
 SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A
 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A
 FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED
 BY EMAIL ([email protected]) OR IN WRITING (FAX:
 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE
 MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.?
  
 SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM.
  
 SUE ELLEN CALDERON
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-11-04 Cont ID  
Sent By jwitmer Date 2013-11-04 Time 15:24 Rev Time 0.00
Received By jwitmer Date 2013-10-29 Time 18:35 Sent To  
Notes
2013-10-31 18:35:44TO JW DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-10-25 Cont ID  
Sent By skennedy Date 2013-10-25 Time 15:19 Rev Time 0.00
Received By skennedy Date 2013-09-30 Time 07:35 Sent To  
Notes
2013-10-01 07:37:09B12