Plan Review Details - Permit 13090669
Plan Review Stops For Permit 13090669 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2013-11-27 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2013-11-27 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2013-11-27 |
Time |
11:53 |
Sent To |
I |
|
Notes |
2013-11-27 12:22:17 | SENT TO SH DESK | 2013-11-27 12:21:28 | PROVISIOS: | | 1. THE SCOPE OF THIS PERMIT IS AS INDICATED ON THE | | PERMIT APPLICATION, TO REMOVE AND REPLACE BROKEN METER | | SOCKET AND RISER PIPE. IF THE REMOVAL OF THE METER | | SOCKET CREATES A SITUATION WHERE THE FEEDERS MUST BE | | REPLACED, THE NEW WIRING, REGARDLESS OF WHAT IS | | EXISTING, SHALL BE IN ACCORDANCE WITH THE CURRENT | | EDITION OF THE NEC. | | 2. ALL GROUNDING SYSTEM SHALL BE REPLACED AND MADE | | CURRENT, INCLUDING THE INSTALLATION OF THE INTER-SYSTEM | | BONDING TERMINAL REQUIRED BY NEC 250.94. | | 3. ALL WORK SHALL COMPLY WITH ALL REQUIREMENTS OF THE | | 2008 EDITION OF THE NEC AND IS SUBJECT TO THE APPROVAL | | OF THE FIELD INSPECTOR. | 2013-11-27 11:54:52 | THE CONTRACTOR CALLED IN THIS MORNING ALLEGING THAT | | DOUG HAD ALREADY SIGNED OFF ON THIS PERMIT, BUT THE | | RECORDS DO NOT REFLECT SUCH. I WILL ONCE AGAIN LOOK AT | | THE SUBMITTAL AND EVALUATE THE CIRCUMSTANCES. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-09-26 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-09-26 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-09-26 |
Time |
14:52 |
Sent To |
|
|
Notes |
2013-09-26 15:08:16 | 13090669 | | 4000 GREEN WOOD | | NEW ELECTRIC SERVICE | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | ELECTRICAL REVIEW COMMENTS. | | | | SHOW LOCATION OF ALL SERVICE DISCONNECTS. A BUILDING OR | | OTHER STRUCTURE SERVED SHALL BE SUPPLIED BY ONLY ONE | | SERVICE. MAIN DISCONNECTS ARE REQUIRED TO BE GROUPED IN | | ONE LOCATION. NEC 230.2 | | | | SERVICE CONDUCTORS NEED TO BE RATED FOR WET LOCATION. | | NEC 310.10 | | | | INDICATE THE SIZE, RATING, AND LOCATION OF THE EXISTING | | PANEL BOARDS. INDICATE SIZE OF PANEL FEEDERS. NEC 215.5 | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | INCLUDE INTERCONNECTED SMOKE DETECTORS. FBC R313 | | | | A BONDING STRIP IS REQUIRED AT SERVICE GROUND NEC | | 250.94 | | | | ROBERT LECKY | | ELECTRICAL PLANS EXAMINER | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-12-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-09-26 |
Time |
10:18 |
Rev Time |
|
Received By |
shill |
Date |
2013-09-20 |
Time |
|
Sent To |
|
|
Notes |
2013-09-20 15:43:32 | <5000 ELEC |
|
|
|