Plan Review Stops For Permit 13090634 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2014-05-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-05-30 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-30 |
Time |
11:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2014-05-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-05-01 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-01 |
Time |
12:04 |
Sent To |
|
|
Notes |
2014-05-01 15:04:22 | BUILDING PLAN REVIEW | | PERMIT: 13090634 | | ADD: 800 HANK AARON DRIVE / MIZNER LAKES | | SITE AMENITIES: 1) POOL RESTROOMS, 2) TOWER FEATURE & | | 3) GATE HOUSE 4) DUMPSTER ENCLOSURE & 5) MAIL KIOSK | | CONT: KAST CONSTRUCTION | | TEL: (561)324-8082 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 3RD REVIEW | | DATE: THURS. MAY 01/ 2014 | | ACTION: DENIED | | | | 1) THIS PERMIT IS INCLUDES SITE AMENITIES: 1) POOL | | RESTROOMS, 2) TOWER FEATURE & 3) GATE HOUSE, 4) | | DUMPSTER ENCLOSURE & 5) MAIL KIOSK. CLUBHOUSE UNDER A | | SEPARATE PERMIT AS WELL AS POOL & DECK. | | | | 2-11) COMPLIED. | | | | 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2014-02-18 |
|
|
Cont ID |
|
Sent By |
rferguso |
Date |
2014-01-27 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-02-18 |
Time |
14:16 |
Sent To |
|
|
Notes |
2014-02-18 14:43:26 | BUILDING PLAN REVIEW | | PERMIT: 13090634 | | ADD: 800 HANK AARON DRIVE / MIZNER LAKES | | SITE AMENITIES: 1) POOL RESTROOMS, 2) TOWER FEATURE & | | 3) GATE HOUSE 4) DUMPSTER ENCLOSURE & 5) MAIL KIOSK | | CONT: KAST CONSTRUCTION | | TEL: (561)324-8082 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2ND REVIEW | | DATE: TUES. FEB. 18/ 2014 | | ACTION: DENIED | | | | 1) THIS PERMIT IS INCLUDES SITE AMENITIES: 1) POOL | | RESTROOMS, 2) TOWER FEATURE & 3) GATE HOUSE, 4) | | DUMPSTER ENCLOSURE & 5) MAIL KIOSK. CLUBHOUSE UNDER A | | SEPARATE PERMIT AS WELL AS POOL & DECK. | | | | 2) COMPLIED. | | WITHIN THE SUBMITTED SOILS REPORT BASED ON THE RESULTS, | | LOOSE SOILS AND SOFT ORGANIC SOIL (MUCK) LAYER WAS | | FOUND. THE PLANS DO NOT INDICATE WHICH OF THE THREE | | OPTIONS WERE PICKED FOR THIS PROJECT, THIS MAY AFFECT | | THE TYPE OF FOUNDATION. PLEASE PROVIDE ADDITIONAL | | INFORMATION. 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. | | A SEPARATE PERMIT WILL BE REQUIRED FOR SOILS WORK. | | | | 3) OMITTED. | | | | 4-5) COMPLIED. | | PRODUCT APPROVALS. | | | | 6) 2ND REQUEST. SHEET A101 THE GATEHOUSE DOES NOT SHOW | | A ACCESSIBLE PATH TO THE GATE HOUSE NOR DOES SHEET | | A102. | | THE RESPONSE INDICATES A REVISION # 3, THE PLANS | | SUBMITTED SHOW REVISION # 2. THERE IS ALSO A | | DISCREPENCY BETWEEN SHEET A102 AND A101 & S2 BOTH SHOW | | A SIDE ENTRY DOOR WHERE AS A101 A END ENTRY DOOR. | | SHEET A102 SHOW ACCESSIBLE ROUTE INTO THE GATE/ GUARD | | HOUSE. 2010 FL ACCESSIBILITY 206.2.2 ACCESSIBLE ROUTE | | WITHIN THE SITE AND TO BUILDINGS. | | | | 7-10) COMPLIED. | | | | 11) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-11-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-11-02 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-11-02 |
Time |
14:13 |
Sent To |
|
|
Notes |
2013-11-02 15:33:40 | BUILDING PLAN REVIEW | | PERMIT: 13090634 | | ADD: 800 HANK AARON DRIVE / MIZNER LAKES | | SITE AMENITIES: 1) POOL RESTROOMS, 2) TOWER FEATURE & | | 3) GATE HOUSE 4) DUMPSTER ENCLOSURE & 5) MAIL KIOSK | | CONT: KAST CONSTRUCTION | | TEL: (561)324-8082 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 1ST REVIEW | | DATE: SAT. NOV. 02/ 2013 | | ACTION: DENIED | | | | 1) THIS PERMIT IS INCLUDES SITE AMENITIES: 1) POOL | | RESTROOMS, 2) TOWER FEATURE & 3) GATE HOUSE, 4) | | DUMPSTER ENCLOSURE & 5) MAIL KIOSK. CLUBHOUSE UNDER A | | SEPARATE PERMIT AS WELL AS POOL & DECK. | | | | 2) WITHIN THE SUBMITTED SOILS REPORT BASED ON THE | | RESULTS, LOOSE SOILS AND SOFT ORGANIC SOIL (MUCK) LAYER | | WAS FOUND. THE PLANS DO NOT INDICATE WHICH OF THE THREE | | OPTIONS WERE PICKED FOR THIS PROJECT, THIS MAY AFFECT | | THE TYPE OF FOUNDATION. PLEASE PROVIDE ADDITIONAL | | INFORMATION. 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. | | A SEPARATE PERMIT WILL BE REQUIRED FOR SOILS WORK. | | | | 3) OMITTED. | | | | 4A) PLEASE NOTE PRODUCT APPROVALS WERE SUBMITTED, THEY | | ARE NOT INDICATED AS TO WHICH BUILDING THEY ARE GOING | | TO BE INSTALLED. WE WILL ASSUME WORST CASE SCENARIO, | | FOR WALL OPENINGS WE WILL BE LOOKING AT A EXTERIOR | | CORNER ZONE, ZONE 5, 10 SQ. FT. A ROOF HEIGHT MEAN ROOF | | HEIGHT FOR THE 4 STORY BUILDING AND A ?C? EXPOSURE | | CATEGORY. THE SAME WILL HOLD TRUE FOR ALL ROOFING | | PRODUCTS UNLESS THE PRODUCTS ARE BROUGHT IN BUILDING | | TYPE SPECIFIC, WORST CASE SCENARIO. | | THE SUBMITTED APPROVALS WILL NOT BE REVIEWED BECAUSE OF | | TOO MANY UNKNOWNS. | | 4B) PLEASE IDENTIFY FOR GLAZED OPENINGS, WINDOWS & | | DOORS TYPE OF GLAZING, SIZE OF WINDOWS, & ASSOCIATED | | PRESSURES. 2010 FBC-B 1609.6.4.4.1. COMPONENTS & | | CLADDING. | | 4C) FOR ROOFING APPROVALS, PLEASE IDENTIFY SUB-SYSTEMS | | AND ASSOCIATED PRESSURES. | | SEE IF LIMITATION # 7 OR LIMITATION #9 APPLIES, IF | | LIMITATION # 7 APPLIES, PLEASE PROVIDE ENHANCED | | FASTENING AS TO RAS 117. | | | | 5) SHEET A002 BUILDING DATA SHEET DECLARES THE BUILDING | | TYPE FOR THE 3 & 4 STORY R-2 APARTMENT BUILDINGS BUT | | NOT THE SITE AMENITIES., | | | | 6) SHEET A102 SHOW ACCESSIBLE ROUTE INTO THE GATE/ | | GUARD HOUSE. 2010 FL ACCESSIBILITY 206.2.2 ACCESSIBLE | | ROUTE WITHIN THE SITE AND TO BUILDINGS. | | | | 7) 2010 FBC-C 1209.2 ATTIC SPACES. NONE OF THE A SHEETS | | SHOW ACCESS TO EITHER THE ATTIC SPACE IN THE GATE HOUSE | | OR POOL RESTROOMS. AN OPENING NOT LESS THAN 20 INCHES | | BY 30 INCHES (559 MM BY 762 MM) SHALL BE PROVIDED TO | | ANY ATTIC AREA HAVING A CLEAR HEIGHT OF OVER 30 INCHES | | (762 MM). A 30-INCH (762 MM) MINIMUM CLEAR HEADROOM IN | | THE ATTIC SPACE SHALL BE PROVIDED AT OR ABOVE THE | | ACCESS OPENING. | | | | 8) SHEET A104 & A105 BOTH INDICATE THE USE OF DROPPED | | CEILINGS IN BOTH THE GATE HOUSE & POOL RESTROOMS PLANS | | INDICATE 5/8? DRYWALL AS A FINISH BUT THE HORIZONTAL | | FRAMING MEMBERS ARE NOT INDICATED AS TO MATERIAL, SIZE, | | SPACING OR ATTACHMENT TO THE CMU CONSTRUCTION NOR | | SPANS. 107.3.5.1.1 MINIMUM PLAN REVIEW CRITERIA FOR | | COMMERCIAL BUILDINGS. | | | | 9) SHEET S6 PLYWOOD SHEATHING NOTE D & E INDICATE SEE | | FRAMING PLAN FOR TYPE AND SIZE OF NAILS, WHERE, PROVIDE | | FOR ROOF SHEATHING ZONES 1, 2 & 3. PLEASE PROVIDE | | NAILING FOR THE APPROPRIATE WIND EXPOSURE AND HEIGHT | | FACTORS FOR THIS BUILDING. 107.3.5.1.1 MINIMUM PLAN | | REVIEW CRITERIA FOR COMMERCIAL BUILDINGS. PART OF THE | | MWFRS, MAIN WIND FORCE RESISTING SYSTEM. | | | | 10) 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | CHAPTER 6 OF ASCE 7-10. 1609.3 BASIC WIND SPEED FIGURE | | 1609.A-C | | 1609.3 WIND SPEED CONVERSION | | 1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN | | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 | | 2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. | | 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | ACCORDANCE WITH 1609.4 & ASCE 7-10 | | 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. | | 5) COMPONENTS & CLADDING PRESSURES POSITIVE & NEGATIVE | | TABLE 1609.2(2) .PROVIDE PRESSURES FOR ZONES 1-5. | | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-02-19 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2014-02-19 |
Time |
18:35 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2014-02-19 |
Time |
16:57 |
Sent To |
|
|
Notes |
2014-02-19 18:36:25 | RETURNED TO BIN FOR FURTHER REVIEWS |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-12-30 |
|
|
Cont ID |
|
Sent By |
rferguso |
Date |
2013-12-12 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2013-12-16 |
Time |
08:38 |
Sent To |
I |
|
Notes |
2013-12-16 11:06:52 | RETURNED TO BIN | | THE RISER DIAGRAM REFLECTED ON THIS PERMIT ADDRESSES | | ITEMS NOT DIRECTLY A P[ART OF THIS PERMIT. HENCE: THE | | LOCATION OF LCP1 & LPA1, BOTH IN THE CLUB HOUSE. | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2013-10-29 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2013-10-29 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2013-10-29 |
Time |
|
Sent To |
Z |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2014-01-27 |
|
|
Cont ID |
|
Sent By |
rferguso |
Date |
2014-01-27 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
rferguso |
Date |
2014-01-27 |
Time |
15:24 |
Sent To |
B |
|
Notes |
2014-01-22 16:04:21 | 800 HANK AARON DRIVE | | PERMIT #13090634 | | | | * PLAN REVIEWED BY FIRE (OK). | | | | | | RONALD E. FERGUSON, ASSISTANT FIRE MARSHAL | | BUREAU OF FIRE PREVENTION | | WEST PALM BEACH FIRE RESCUE | | PHONE (561) 804-4700 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2013-12-12 |
|
|
Cont ID |
|
Sent By |
rferguso |
Date |
2013-12-10 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
rferguso |
Date |
2013-11-25 |
Time |
12:48 |
Sent To |
E |
|
Notes |
2013-12-10 12:18:50 | 800 HANK AARON DRIVE | | PERMIT #13090634 | | | | WEST PALM BEACH FIRE RESCUE COMMENTS. | | | | * INDICATE IF GATE HOUSE IS MANNED OR UNMANNED FOR 24 | | HOURS AND IF NOT, INSTALL A KNOX BOX WITH A KEY OR CARD | | THAT CONTOLS BOTH GATE ARMS. | | | | * MAINTAIN A CONTINIOUS WIDTH OF 20' FEET AND HIGHT OF | | 13' FEET 6" INCHES AT GATE ENTRIES/EXITS WITH NO | | ENTRUSSIONS THROUGHOUT FIRE EMERGENCY ACCES ROUTS. | | | | * INSALL CLEAR FIRE LANE SIGNS AND MARKINGS WHERE | | NEEDED. | | | | | | RONALD E. FERGUSON, ASSISTANT FIRE MARSHAL | | BUREAU OF FIRE PREVENTION | | WEST PALM BEACH FIRE RESCUE | | PHONE #(561) 804-4700 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2014-05-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-05-30 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-30 |
Time |
11:27 |
Sent To |
|
|
Notes |
2014-05-30 11:29:31 | FUEL GAS PLAN REVIEW | | PERMIT: 13090634 | | ADD: 800 HANK AARON DRIVE / MIZNER LAKES | | SITE AMENITIES: 1) POOL RESTROOMS, 2) TOWER FEATURE & | | 3) GATE HOUSE 4) DUMPSTER ENCLOSURE & 5) MAIL KIOSK | | CONT: KAST CONSTRUCTION | | TEL: (561)324-8082 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2ND REVIEW | | DATE: FRI. MAY 30/ 2014 | | ACTION: PROVISO | | | | GAS IS UNDER A SEPARATE PERMIT, IT MAY BE SHOWN UNDER | | THE SITE AMENITIES PERMIT. | | PROVISO: | | 1) REQUIREMENTS FOR GAS PLAN REVIEW. SUBMIT MANUFACTURE | | SHEETS FOR ALL GAS EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND FBC-2010 FUEL GAS SEC. | | 402.2 | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2014-05-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-05-01 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-01 |
Time |
14:27 |
Sent To |
|
|
Notes |
2014-05-01 14:27:26 | FUEL GAS PLAN REVIEW | | PERMIT: 13090634 | | ADD: 800 HANK AARON DRIVE / MIZNER LAKES | | SITE AMENITIES: 1) POOL RESTROOMS, 2) TOWER FEATURE & | | 3) GATE HOUSE 4) DUMPSTER ENCLOSURE & 5) MAIL KIOSK | | CONT: KAST CONSTRUCTION | | TEL: (561)324-8082 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 1ST REVIEW | | DATE:THURS. MAY 01/ 2014 | | ACTION: DENIED | | | | GAS IS UNDER A SEPARATE PERMIT, IT MAY BE SHOWN UNDER | | THE SITE AMENITIES PERMIT BUT THE SITE AMENITIES PERMIT | | WILL NOT BE ISSUED UNTIL ALL REQUIREMENTS CAN BE MET | | FOR CODE COMPLIANCE. | | | | 1) SHEET P3.1 SHOWS A GAS PLAN FOR THE FIRST TIME, | | COMMENT ON THE GAS PLAN INDICATES SEE SHEET P1.2 FOR | | CONTINUATION, PLEASE NOTE NO SUCH SHEET WAS SUBMITTED | | FOR REVIEW. | | | | 2) SHEET P2.1 WAS SUBMITTED WITH A REV.# 2 CLOUDED, IF | | THERE IS TO BE A GAS LINE WITHIN THE CLOUD, IT WAS | | NEVER DRAWN, OR LAYER TURNED ON TO INDICATE A NEW GAS | | LINE. | | | | 3)REQUIREMENTS FOR GAS PLAN REVIEW. SUBMIT MANUFACTURE | | SHEETS FOR ALL GAS EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND FBC-2010 FUEL GAS SEC. | | 402.2 | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2014-05-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-05-01 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-01 |
Time |
14:26 |
Sent To |
|
|
Notes |
2014-05-01 14:27:02 | FUEL GAS PLAN REVIEW | | PERMIT: 13090634 | | ADD: 800 HANK AARON DRIVE / MIZNER LAKES | | SITE AMENITIES: 1) POOL RESTROOMS, 2) TOWER FEATURE & | | 3) GATE HOUSE 4) DUMPSTER ENCLOSURE & 5) MAIL KIOSK | | CONT: KAST CONSTRUCTION | | TEL: (561)324-8082 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 1ST REVIEW | | DATE:THURS. MAY 01/ 2014 | | ACTION: DENIED | | | | GAS IS UNDER A SEPARATE PERMIT, IT MAY BE SHOWN UNDER | | THE SITE AMENITIES PERMIT BUT THE SITE AMENITIES PERMIT | | WILL NOT BE ISSUED UNTIL ALL REQUIREMENTS CAN BE MET | | FOR CODE COMPLIANCE. | | | | 1) SHEET P3.1 SHOWS A GAS PLAN FOR THE FIRST TIME, | | COMMENT ON THE GAS PLAN INDICATES SEE SHEET P1.2 FOR | | CONTINUATION, PLEASE NOTE NO SUCH SHEET WAS SUBMITTED | | FOR REVIEW. | | | | 2) SHEET P2.1 WAS SUBMITTED WITH A REV.# 2 CLOUDED, IF | | THERE IS TO BE A GAS LINE WITHIN THE CLOUD, IT WAS | | NEVER DRAWN, OR LAYER TURNED ON TO INDICATE A NEW GAS | | LINE. | | | | 3)REQUIREMENTS FOR GAS PLAN REVIEW. SUBMIT MANUFACTURE | | SHEETS FOR ALL GAS EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND FBC-2010 FUEL GAS SEC. | | 402.2 | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2014-05-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-05-01 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-01 |
Time |
14:04 |
Sent To |
|
|
Notes |
2014-05-01 14:25:36 | FUEL GAS PLAN REVIEW | | PERMIT: 13090634 | | ADD: 800 HANK AARON DRIVE / MIZNER LAKES | | SITE AMENITIES: 1) POOL RESTROOMS, 2) TOWER FEATURE & | | 3) GATE HOUSE 4) DUMPSTER ENCLOSURE & 5) MAIL KIOSK | | CONT: KAST CONSTRUCTION | | TEL: (561)324-8082 | | | | 2010 FLORIDA BUILDING CODE W | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 1ST REVIEW | | DATE:THURS. MAY 01/ 2014 | | ACTION: DENIED | | | | GAS IS UNDER A SEPARATE PERMIT, IT MAY BE SHOWN UNDER | | THE SITE AMENITIES PERMIT BUT THE SITE AMENITIES PERMIT | | WILL NOT BE ISSUED UNTIL ALL REQUIREMENTS CAN BE MET | | FOR CODE COMPLIANCE. | | | | 1) SHEET P3.1 SHOWS A GAS PLAN FOR THE FIRST TIME, | | COMMENT ON THE GAS PLAN INDICATES SEE SHEET P1.2 FOR | | CONTINUATION, PLEASE NOTE NO SUCH SHEET WAS SUBMITTED | | FOR REVIEW. | | | | 2) SHEET P2.1 WAS SUBMITTED WITH A REV.# 2 CLOUDED, IF | | THERE IS TO BE A GAS LINE WITHIN THE CLOUD, IT WAS | | NEVER DRAWN, OR LAYER TURNED ON TO INDICATE A NEW GAS | | LINE. | | | | 3)REQUIREMENTS FOR GAS PLAN REVIEW. SUBMIT MANUFACTURE | | SHEETS FOR ALL GAS EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND FBC-2010 FUEL GAS SEC. | | 402.2 | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2014-06-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-06-13 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-12 |
Time |
19:06 |
Sent To |
|
|
Notes |
2014-05-13 19:07:31 | SENT TO J WITMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
|
Date |
2014-05-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-05-01 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-04-12 |
Time |
14:22 |
Sent To |
|
|
Notes |
2014-04-12 14:23:18 | SENT TO C-39. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-03-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2014-03-19 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2014-01-15 |
Time |
08:08 |
Sent To |
|
|
Notes |
2014-01-18 08:09:29 | 01/15/2014 1ST RESUBMITTAL SENT TO C-33. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-12-16 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2013-12-12 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-09-20 |
Time |
13:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
5 |
Status |
N |
Date |
2014-06-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-06-12 |
Time |
06:08 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-06-12 |
Time |
06:07 |
Sent To |
|
|
Notes |
2014-06-12 06:08:33 | IMPACT FEES PAID: | | STAMPED NO FEES DUE. JW |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
N |
Date |
2014-05-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-05-30 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-30 |
Time |
11:24 |
Sent To |
|
|
Notes |
2014-05-30 11:25:21 | SITE AMENITIES NO FEES DUE. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2014-05-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-05-01 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-01 |
Time |
14:28 |
Sent To |
|
|
Notes |
2014-05-01 14:28:19 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2014-02-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-02-18 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-02-18 |
Time |
14:44 |
Sent To |
|
|
Notes |
2014-02-18 14:44:23 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2013-11-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-11-02 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-11-02 |
Time |
15:33 |
Sent To |
|
|
Notes |
2013-11-02 15:34:28 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2014-05-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-05-01 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-01 |
Time |
15:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2013-10-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-10-19 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-10-19 |
Time |
10:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2014-05-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2014-05-30 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2014-05-30 |
Time |
11:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2013-10-07 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-10-07 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-10-07 |
Time |
09:23 |
Sent To |
|
|
Notes |
2013-10-11 14:02:51 | ***PROVISO*** | | A DOMESTIC WATER PUMP/S MAY BE REQUIRED. REQUIRED | | MINIMUM FLOW PRESSURE AT TOP FLOOR IS 20 PSI AT PEAK | | DEMAND. | | FBC PLUMBING 2010 TABLE 604.3 | | WATER DISTRIBUTION SYSTEM DESIGN CRITERIA | | REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2014-06-12 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2014-06-12 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2014-06-12 |
Time |
16:21 |
Sent To |
|
|
Notes |
2014-06-12 16:22:53 | 6/12/14 SEPERATE PERMIT REQUIRED FOR POOL'S RESTROOM | | BUILDING. | | ANGELLA VANN, PLANNNG AND ZONING ADMINISTRATOR | | 561-822-1441 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2014-04-30 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2014-04-30 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2014-04-30 |
Time |
13:29 |
Sent To |
|
|
Notes |
2014-04-30 13:30:13 | SEE COMMENT FROM 2ND REVIEW |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2014-03-19 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2014-03-19 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2014-03-19 |
Time |
09:07 |
Sent To |
|
|
Notes |
2014-03-19 09:31:44 | 3/19/14- THE REQUIREMENTS OF RESOLUTION NO. 321-12 | | SECTION 4 (3) (C) MUST BE COMPLETED PRIOR TO THE | | ISSUANCE OF THE FIRST BUILDING PERMIT. AS OF THIS DATE | | THE ITEM HAS NOT BEEN ADDRESSED. | | | | ANGELLA VANN, PLANNING AND ZONING ADMINISTRATOR | | 561-822-1441 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2013-12-12 |
|
|
Cont ID |
|
Sent By |
avann |
Date |
2013-12-12 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2013-12-12 |
Time |
14:45 |
Sent To |
|
|
Notes |
2013-12-12 14:45:34 | 12/12/13- REVEWING THE MINOR PD AMENDMENT | | | | ANGELLA VANN | | 561-822-1441 | | [email protected] | 2013-09-30 10:40:11 | 9/30/13 |
|
|