Plan Review Details - Permit 13090506
Plan Review Stops For Permit 13090506
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2014-07-09 Cont ID  
Sent By jgomez Date 2014-07-09 Time 14:26 Rev Time 0.00
Received By jgomez Date 2014-07-09 Time 14:26 Sent To  
Notes
2014-07-09 14:26:37ENTRY DOOR PRODUCT APPROVAL SUBMITTED. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2014-06-03 Cont ID  
Sent By jgomez Date 2014-04-25 Time 08:43 Rev Time 0.00
Received By jgomez Date 2014-04-25 Time 08:43 Sent To  
Notes
2014-04-25 08:48:13NEED DOORS PRODUCT APPROVALS AS REQUESTED ON ORIGINAL
 PROVISO WHEN THE PERMIT WAS ISSUED. THE EXTERIOR DOORS
 PRODUCT APPROVALS WERE NEVER SUBMITTED FOR REVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT.
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2014-03-24 Cont ID  
Sent By jgomez Date 2014-03-20 Time 11:45 Rev Time 0.00
Received By jgomez Date 2014-03-20 Time 11:44 Sent To  
Notes
2014-03-20 13:18:19REVISION CHECKLIST.
 CODE: 2010 FBC.
  
 1- ACCORDING TO BUILDING INSPECTOR'S INSPECTION, THE
 BUILDING INTERIOR WAS ALL GUTTED OUT AND REBUILT. THIS
 IS NOT WHAT THE ORIGINAL APPROVED PLANS SHOW. PROVIDE
 ENGINEER STRUCTURAL ANALYSIS AND PLANS WITH COMPLETE
 SPECIFICATIONS AS REQUIRED BY SEC. 807 OF 2010
 FBC-EXISTING BUILDING.
  
 2- REVISE SCOPE OF WORK VALUATION TO INCLUDE ALL THE
 PROPOSED WORK AND DESIGN PROFESSIONAL FEES AS REQUIRED
 BY SEC. 109.3 OF CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2014-01-03 Cont ID  
Sent By jgomez Date 2014-01-03 Time 13:53 Rev Time 0.00
Received By jgomez Date 2014-01-03 Time 13:53 Sent To  
Notes
2014-01-03 13:53:50REVISION BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 ***NOTE:
 REVISIONS TO EXTERIOR OF BUILDING NEED TO BE APPROVED
 BY HISTORIC.
  
  
 1- PLANS SUBMITTED ARE DIFFERENT FROM THE ONES THAT
 WERE APPROVED. PROVIDE COMPLETE FRAMING DETAILS AND
 SPECIFICATIONS FOR THE CLOSING OF EXISTING EXTERIOR
 OPENINGS TO SHOW COMPLIANCE WITH SEC. R301 OF 2010
 FBC-RESIDENTIAL.
  
 2- PLANS SHOW REMOVING PORTION OF EXISTING STAIRWAY
 WALLS TO ALLOW FOR NEW IRON HAND-RAILINGS. AND NEW
 OPENING FOR HALF BATHROOM ENTRANCE. THESE WALLS SEEM TO
 BE BEARING WALLS. PROVIDE COMPLETE ENGINEERING
 ANALYSIS, DETAILS AND SPECIFICATIONS TO SHOW THAT
 STRUCTURE IS GOING TO BE STRUCTURALLY SOUND. SEC. R301
 OF 2010 FBC AND SEC. 107.2.1.3 OF CITY AMENDMENTS TO
 FBC.
  
 3- PROVIDE COMPLETE CONSTRUCTION DETAILS AND
 SPECIFICATIONS FOR THE NEW HANDRAIL/GUARDRAIL TO SHOW
 COMPLIANCE WITH SEC. R311.7.7 AND THE LIVE LOADS AS
 REQUIRED BY TABLE R301.5 OF 2010 FBC-RESIDENTIAL.
  
 4- PROVIDE DIMENSIONS FOR ALTERATIONS ON BEDROOM #3 TO
 SHOW COMPLIANCE WITH SEC. R304 OF 2010 FBC-RESIDENTIAL.
  
  
 ***NOTE: NEED A/C AND PLUMBING PERMITS.
  
  
 ****REMAINDER: THE FOLLOWING INFORMATION REQUESTED ON
 PROVISO NEED TO BE PROVIDED.
  
 1- PROVIDE PRODUCT APPROVAL FOR EXTERIOR DOORS (AS
 REQUESTED ON PROVISO. (SEE APPROVED PLANS).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-11-13 Cont ID  
Sent By jgomez Date 2013-11-13 Time 17:18 Rev Time 0.00
Received By jgomez Date 2013-11-13 Time 17:15 Sent To  
Notes
2013-11-13 17:19:39 
 ***NOTE: PENDING HISTORICAL APPROVAL TO PASS BUILDING
 STOP. JG.
  
  
 ****REMAINDER: THE FOLLOWING INFORMATION REQUESTED ON
 PROVISO NEED TO BE PROVIDED.
  
 1- PROVIDE PRODUCT APPROVAL FOR EXTERIOR DOORS (AS
 REQUESTED ON PROVISO. (SEE APPROVED PLANS).
  
 2- PROVIDE COMPLETE INFORMATION FOR A/C UNDER A
 SEPARATE PERMIT. (NO INFORMATION SUBMITTED YET).
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-09-26 Cont ID  
Sent By GOMEZ Date 2013-09-26 Time 09:26 Rev Time 0.00
Received By jgomez Date 2013-09-26 Time 09:26 Sent To  
Notes
2013-09-26 09:32:10RESIDENTIAL (R3) REVISION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1-ENERGY CALCULATIONS SUBMITTED:
 A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING THE CORRECT BUILDER'S NAME. SEC. 103.2.1.1.2
 OF 2010 FBC-ENERGY CONSERVATION.
  
 B) PROVIDE MANUFACTURER'S DOCUMENTATION SHOWING THE
 WINDOWS U-FACTOR AND SHGC FACTOR AS SPECIFIED ON ITEM
 #7(A). SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 C) CALCULATIONS NEED TO BE CERTIFIED AND DATED AT THE
 BOTTOM OF THE FORM BY THE PERSON WHO PREPARED THEM.
 SEC. 405.4.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 D) ITEM #9(A) SPECIFIES R-13 IN EXTERIOR WALLS. TYPICAL
 WALL DETAIL ON FLOOR PLANS SUBMITTED SPECIFY R-11.
 REVISE AS REQUIRED TO MATCH. SEC. 103.2.2 OF 2010
 FBC-ENERGY CONSERVATION.
  
 E) REVISE THE OVERHANG DEPTH AND SEPARATION SPECIFIED
 FOR THE WINDOWS ON PAGE 4 OF 6 TO MATCH HOUSE.
  
 ***NOTE: THIS IS A 2 STORY HOUSE WITH FLAT ROOF AND NO
 OVERHANGS.
  
 2- PLANS SUBMITTED NEED TO BE SIGNED AND DATED BY THE
 PERSON RESPONSIBLE FOR THE DESIGN. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC.
  
  
 ****REMAINDER: THE FOLLOWING INFORMATION NEED TO BE
 PROVIDED.
  
 1- PROVIDE PRODUCT APPROVAL FOR EXTERIOR DOORS (AS
 REQUESTED ON PROVISO. (SEE APPROVED PLANS).
  
 2- PROVIDE COMPLETE INFORMATION FOR A/C UNDER A
 SEPARATE PERMIT. (NO INFORMATION SUBMITTED YET).
  
  
 ********* PLEASE PROVIDE A RESPONSE LETTER ADDRESSING
 EACH COMMENT TO EXPEDITE THE REVIEW PROCESS********
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-10-31 Cont ID  
Sent By dhayes Date 2014-10-31 Time 16:55 Rev Time 0.00
Received By dhayes Date 2014-10-31 Time 16:55 Sent To  
Notes
2014-10-31 16:58:4410/31/2014
 PROJECT:
 PERMIT#: 14080234
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 ELECTRICAL PLAN REVIEW
 ACTION: APPROVED WITH EXCEPTION.
  
 1) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL
 314 AND 315. INTERCONNECTED SMOKE DETECTORS ARE NOTED
 ON THE PLAN. HOWEVER WHEN THERE IS GAS OR A FIREPLACE
 THERE NEEDS TO BE CO DETECTORS WITH 10' OF SLEEPING
 AREAS. PLEASE COMPLY WITH FBC-R 314-315
  
 2) ALL NEW GENERAL PURPOSE OUTLETS MUST BE TAMPER
 RESISTANT AND AFCI PROTECTED. NEC 210.12, 406.11.
  
 3) RECEPTACLES SHALL BE INSTALLED SUCH THAT NO POINT
 MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY WALL
 SPACE IS MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE
 OUTLET. NEC 210.52(A)(1)
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-10-23 Cont ID  
Sent By albarran Date 2013-10-23 Time 16:08 Rev Time 0.00
Received By albarran Date 2013-10-23 Time 15:40 Sent To  
Notes
2013-10-23 16:13:09IN ADDITION TO OTHER DISCREPANCIES NOTE NOTED, A FEW
 CHANGES AND CORRECTIONS WILL HAVE TO TAKE PLACE ON THE
 JOB FOR SUCCESSFUL INSPECTIONS:
 1. THE PLANS CURRENTLY CALL FOR AFCI ONLY IN THE
 BEDROOMS, NEC 2008 STATES DIFFERENTLY.
 2. TAMPER-RESISTANT RECEPTACLES SHALL BE REQUIRED
 THROUGH OUT THE HOME.
 3. ALL EXTERIOR RECEPTACLE SHALL BE RATED "WR"
 4. DUE TO THE GAS FIRE PLACE, CARBON MONOXIDE DETECTORS
 SHALL BE REQUIRED WITHIN 10' OF THE SLEEPING AREAS.

Review Stop HIST HISTORICAL
Rev No 6 Status P Date 2014-06-03 Cont ID  
Sent By fmittner Date 2014-06-03 Time 09:19 Rev Time 0.00
Received By fmittner Date 2014-06-03 Time 09:19 Sent To  
Notes
2014-06-03 09:20:07APPLICANT SUBMITTED COA AS REQUIRED.

Review Stop HIST HISTORICAL
Rev No 5 Status F Date 2014-05-06 Cont ID  
Sent By fmittner Date 2014-05-06 Time 11:35 Rev Time 0.00
Received By fmittner Date 2014-05-06 Time 11:35 Sent To  
Notes
2014-05-06 11:35:51FILED UNDER SMALL FAILED M
2014-05-06 11:35:14COMMENTS REGARDING WINDOWS FROM PREVIOUS REVIEWS NOT
 RESOLVED. REQUIRES FULL COA APPLICATION.
  
 CONTACT FRIEDERIKE MITTNER AT 822-1457 WITH QUESTIONS.

Review Stop HIST HISTORICAL
Rev No 4 Status F Date 2014-03-11 Cont ID  
Sent By fmittner Date 2014-03-11 Time 10:22 Rev Time 0.00
Received By fmittner Date 2014-03-11 Time 10:22 Sent To B
Notes
2014-03-11 10:22:40COMMENTS REGARDING WINDOWS FROM PREVIOUS REVIEWS NOT
 RESOLVED. REQUIRES FULL COA APPLICATION.
  
 CONTACT FRIEDERIKE MITTNER AT 822-1457 WITH QUESTIONS.

Review Stop HIST HISTORICAL
Rev No 3 Status F Date 2014-01-02 Cont ID  
Sent By fmittner Date 2014-01-02 Time 12:05 Rev Time 0.00
Received By fmittner Date 2014-01-02 Time 12:05 Sent To  
Notes
2014-01-02 12:06:39COMMENTS REGARDING WINDOWS FROM PREVIOUS REVIEWS NOT
 RESOLVED. REQUIRES FULL COA APPLICATION.
  
 CONTACT FRIEDERIKE MITTNER AT 822-1457 WITH QUESTIONS.

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2013-11-07 Cont ID  
Sent By fmittner Date 2013-11-07 Time 16:35 Rev Time 0.00
Received By fmittner Date 2013-11-07 Time 16:35 Sent To  
Notes
2013-11-07 16:37:26COMMENTS STILL NOT ADDRESSED FROM FIRST SUBMITTAL. NEED
 CLEAR ELEVATIONS SHOWING WINDOW LOCATIONS, STYLE, SIZE.
 IF ANY ARE BEING ENCLOSED. CONFIRMATION ALL PORCH
 WINDOWS ARE STAYING AS INDICATED ON PLAN. NO SIZE
 CHANGE PERMITTED. HAD PREVIOUSLY APPROVED BROZE FRAMES,
 CLEAR GLASS 1/1 SINGLE HUNG. MULTIPLE DISCUSSIONS WITH
 DESIGNER. QUESTIONS CONTACT CITY HSITORIC PRESERVATION
 PLANNER, FRIEDERIKE MITTNER AT 822-1457.
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2013-10-01 Cont ID  
Sent By fmittner Date 2013-10-01 Time 14:38 Rev Time 0.00
Received By fmittner Date 2013-10-01 Time 14:38 Sent To E
Notes
2013-10-01 14:41:58CONTRIBUTING HISTORIC PROPERTY. DRAWINGS NOT TO SCALE.
 WINDOWS MUST USE ORIGINAL OPENING SIZE. NO SLIDER
 WINDOWS. PROVIDE FRONT AND SIDE ELVATIONS SHOWING
 REMOVAL OF WINDOW AND ANY CHANGES.
  
 QUESTIONS CONTACT: FRIEDERIKE MITTNER, CITY HISTORIC
 PRESERVATION PLANNER 95610 822-1457
2013-09-30 10:50:169/30/13

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2014-10-31 Cont ID  
Sent By dhayes Date 2014-10-31 Time 17:00 Rev Time 0.00
Received By dhayes Date 2014-10-27 Time 11:39 Sent To  
Notes
2014-10-28 11:39:57SENT TO J. GOMEZ DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2014-07-09 Cont ID  
Sent By jgomez Date 2014-07-09 Time 14:26 Rev Time 0.00
Received By jgomez Date 2014-07-01 Time 17:44 Sent To  
Notes
2014-07-01 17:44:53SENT TO GOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2014-06-11 Cont ID  
Sent By jgomez Date 2014-06-03 Time 09:55 Rev Time 0.00
Received By jgomez Date 2014-04-08 Time 13:01 Sent To  
Notes
2014-06-11 09:56:00LAST REVIEW BY HISTORIC ON 6/3/14.
2014-04-08 13:01:59SENT TO J. GOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2014-03-20 Cont ID  
Sent By jgomez Date 2014-03-20 Time 14:17 Rev Time 0.00
Received By jgomez Date 2014-02-27 Time 07:26 Sent To  
Notes
2014-03-07 16:56:48 
 3/7/14 RESUBMITTAL SENT TO ZONING SHELF FOR FRIEDRIKE'S
 REVIEW. JG.
2014-02-27 07:27:11SENT TO J GOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-01-03 Cont ID  
Sent By jgomez Date 2014-01-03 Time 16:32 Rev Time 0.00
Received By jgomez Date 2013-12-26 Time 15:45 Sent To  
Notes
2013-12-26 15:46:30REVISION RESUBMITTAL SENT TO ZONING FOR FRIEDERIKE'S
 HISTORICAL REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-11-13 Cont ID  
Sent By jgomez Date 2013-11-13 Time 18:22 Rev Time 0.00
Received By jgomez Date 2013-10-24 Time 18:16 Sent To  
Notes
2013-10-28 11:01:0210/28/13 SENT TO ZONING SHELF FOR HISTORIC REVIEW. JG.
2013-10-24 18:16:55SENT TO J GOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-10-24 Cont ID  
Sent By rmcdouga Date 2013-10-24 Time 18:15 Rev Time 0.00
Received By rmcdouga Date 2013-09-18 Time 07:56 Sent To  
Notes
2013-09-26 09:37:429/26/13 REVISION SENT TO R12 SHELF FOR REVIEW. JG.
2013-09-20 07:58:23SENT TO GOMEZ

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2014-03-20 Cont ID  
Sent By jgomez Date 2014-03-20 Time 13:52 Rev Time 0.00
Received By jgomez Date 2014-03-20 Time 13:51 Sent To  
Notes
2014-03-20 13:52:50PROVIDE COMPLETE INFORMATION FOR MECHANICAL WORK UNDER
 A SEPARATE PERMIT. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-01-03 Cont ID  
Sent By jgomez Date 2014-01-03 Time 16:05 Rev Time 0.00
Received By jgomez Date 2014-01-03 Time 16:05 Sent To  
Notes
2014-01-03 16:32:16REVISION MECHANICAL REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE COMPLETE A/C PLANS SHOWING ALL THE EQUIPMENT
 AND DUCTWORK. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 2- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS AS
 REQUIRED BY SEC. 403.6 OF 2010 FBC-ENERGY CONSERVATION.
 ***NOTE: EQUIPMENT LISTED ON THE EQUIPMENT SIZING
 CALCULATIONS TO MATCH EQUIPMENT SHOWN ON THE A/C PLAN.
  
 3- PLANS SUBMITTED SHOW AN A/C UNIT INSIDE AN INTERIOR
 CLOSET ON THE SECOND FLOOR AND AN AHU ON THE ROOF ABOVE
 THE KITCHEN. CLARIFY AS REQUIRED. WHY THE AHU IS
 OUTSIDE?. SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 4- PROVIDE COMPLETE INSTALLATION DETAILS FOR THE
 ANCHORAGE OF UNIT LOCATED ON THE ROOF AS REQUIRED BY
 SEC. M1307.2.1 OF 2010 FBC-RESIDENTIAL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 7 Status P Date   Cont ID  
Sent By   Date 2014-10-31 Time   Rev Time 0.00
Received By tklarge Date 2014-10-31 Time 13:39 Sent To  
Notes
2014-10-31 13:41:14*******PROVISO**********
  
 A REVISED SANITARY RISER SHALL BE ONSITE AT TIME OF
 ROUGH INSPECTION.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 6 Status F Date 2014-07-09 Cont ID  
Sent By jgomez Date 2014-07-09 Time 13:55 Rev Time 0.00
Received By jgomez Date 2014-07-09 Time 13:55 Sent To  
Notes
2014-07-09 14:00:44REVISION FOURTH PLUMBING REVIEW CHECKLIST.
 CODE: 2010 FBC.
  
 ***NOTE: DRAWING SUBMITTED IS THE SAME THAT WAS
 SUBMITTED BEFORE. PLUMBING RISER DIAGRAM WAS NOT
 CORRECTED.
  
  
  
 1- PROVIDE A CORRECT AND COMPLETE PLUMBING RISER
 DIAGRAM THAT MATCHES PROPOSED MASTER BATH AND RELOCATED
 HALF BATH BELOW STAIRS. SEC. 107.3.5.3(11) OF CITY
 AMENDMENTS TO FBC.
  
 *** PLUMBING RISER DIAGRAM SUBMITTED IS INCOMPLETE AND
 IS NOT CORRECT. TO AVOID MORE CONFUSION AND DELAYS,
 PLUMBING RISER DIAGRAM MAY BE DRAWN BY THE LICENSED
 CONTRACTOR RESPONSIBLE FOR THE WORK. IF DOING SO,
 CONTRACTOR TO PROVIDE NAME, LICENSE NUMBER AND
 SIGNATURE ON PLUMBING RISER DIAGRAM. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES
 (561)805-6712
  
  
  

Review Stop P PLUMBING
Rev No 5 Status F Date 2014-04-25 Cont ID  
Sent By jgomez Date 2014-04-25 Time 15:08 Rev Time 0.00
Received By jgomez Date 2014-04-25 Time 15:08 Sent To  
Notes
2014-04-25 15:12:54REVISION THIRD PLUMBING REVIEW CHECKLIST.
 CODE: 2010 FBC.
  
  
 1- PROVIDE A CORRECT AND COMPLETE PLUMBING RISER
 DIAGRAM THAT MATCHES PROPOSED MASTER BATH AND RELOCATED
 HALF BATH BELOW STAIRS. SEC. 107.3.5.3(11) OF CITY
 AMENDMENTS TO FBC.
  
 *** PLUMBING RISER DIAGRAM SUBMITTED IS INCOMPLETE AND
 IS NOT CORRECT. TO AVOID MORE CONFUSION AND DELAYS,
 PLUMBING RISER DIAGRAM MAY BE DRAWN BY THE LICENSED
 CONTRACTOR RESPONSIBLE FOR THE WORK. IF DOING SO,
 CONTRACTOR TO PROVIDE NAME AND SIGNATURE ON PLUMBING
 RISER DIAGRAM. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES
 (561)805-6712
  
  
  

Review Stop P PLUMBING
Rev No 4 Status F Date 2014-03-20 Cont ID  
Sent By jgomez Date 2014-03-20 Time 13:54 Rev Time 0.00
Received By jgomez Date 2014-03-20 Time 13:54 Sent To  
Notes
2014-03-20 13:57:20REVISION SECOND PLUMBING REVIEW CHECKLIST.
 CODE: 2010 FBC.
  
 *** ORIGINAL COMMENT:
 1- PROVIDE A CORRECT AND COMPLETE PLUMBING RISER
 DIAGRAM THAT MATCHES PROPOSED MASTER BATH AND RELOCATED
 HALF BATH BELOW STAIRS. SEC. 107.3.5.3(11) OF CITY
 AMENDMENTS TO FBC.
  
 *** PLUMBING RISER DIAGRAM SUBMITTED IS INCOMPLETE AND
 IS NOT CORRECT. TO AVOID MORE CONFUSION AND DELAYS,
 PLUMBING RISER DIAGRAM MAY BE DRAWN BY THE LICENSED
 CONTRACTOR RESPONSIBLE FOR THE WORK.
  
  
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2014-01-03 Cont ID  
Sent By jgomez Date 2014-01-03 Time 16:32 Rev Time 0.00
Received By jgomez Date 2014-01-03 Time 16:32 Sent To  
Notes
2014-01-03 17:00:47REVISION PLUMBING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE A CORRECT AND COMPLETE PLUMBING RISER
 DIAGRAM THAT MATCHES PROPOSED MASTER BATH AND RELOCATED
 HALF BATH BELOW STAIRS. SEC. 107.3.5.3(11) OF CITY
 AMENDMENTS TO FBC.
  
 2- PROVIDE DIMENSIONS FOR MASTER BATH FIXTURES TO SHOW
 COMPLIANCE WITH SEC. P2705 OF 2010 FBC-RESIDENTIAL.
  
 3- PROVIDE DIMENSIONS FOR MASTER BATHROOM SHOWER TO
 SHOW COMPLIANCE WITH SEC. P2708 OF 2010
 FBC-RESIDENTIAL.
  
 4- RELOCATION OF HALF BATHROOM FIXTURES REQUIRES THE
 FIXTURES TO COMPLY WITH SEC. P2705 OF 2010
 FBC-RESIDENTIAL. PROVIDE DIMENSIONS TO VERIFY
 COMPLIANCE WITH THE REQUIRED CLEARANCES.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-11-13 Cont ID  
Sent By jgomez Date 2013-11-13 Time 18:22 Rev Time 0.00
Received By jgomez Date 2013-11-13 Time 18:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-09-26 Cont ID  
Sent By GOMEZ Date 2013-09-26 Time 10:57 Rev Time 0.00
Received By jgomez Date 2013-09-26 Time 10:56 Sent To  
Notes
2013-09-26 10:58:56RESIDENTIAL (R3) REVISION, PLUMBING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE PLUMBING RISER DIAGRAM AS REQUIRED BY SEC.
 107.3.5.3(11) OF CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 1 Status P Date 2013-10-01 Cont ID  
Sent By fmittner Date 2013-10-01 Time 14:38 Rev Time 0.00
Received By fmittner Date 2013-10-01 Time 14:38 Sent To  
Notes
***NONE***