Plan Review Stops For Permit 13090506 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2014-07-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-07-09 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-07-09 |
Time |
14:26 |
Sent To |
|
|
Notes |
2014-07-09 14:26:37 | ENTRY DOOR PRODUCT APPROVAL SUBMITTED. JG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2014-06-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-04-25 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-04-25 |
Time |
08:43 |
Sent To |
|
|
Notes |
2014-04-25 08:48:13 | NEED DOORS PRODUCT APPROVALS AS REQUESTED ON ORIGINAL | | PROVISO WHEN THE PERMIT WAS ISSUED. THE EXTERIOR DOORS | | PRODUCT APPROVALS WERE NEVER SUBMITTED FOR REVIEW. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT. | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2014-03-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-03-20 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-03-20 |
Time |
11:44 |
Sent To |
|
|
Notes |
2014-03-20 13:18:19 | REVISION CHECKLIST. | | CODE: 2010 FBC. | | | | 1- ACCORDING TO BUILDING INSPECTOR'S INSPECTION, THE | | BUILDING INTERIOR WAS ALL GUTTED OUT AND REBUILT. THIS | | IS NOT WHAT THE ORIGINAL APPROVED PLANS SHOW. PROVIDE | | ENGINEER STRUCTURAL ANALYSIS AND PLANS WITH COMPLETE | | SPECIFICATIONS AS REQUIRED BY SEC. 807 OF 2010 | | FBC-EXISTING BUILDING. | | | | 2- REVISE SCOPE OF WORK VALUATION TO INCLUDE ALL THE | | PROPOSED WORK AND DESIGN PROFESSIONAL FEES AS REQUIRED | | BY SEC. 109.3 OF CITY AMENDMENTS TO FBC. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2014-01-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-01-03 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-01-03 |
Time |
13:53 |
Sent To |
|
|
Notes |
2014-01-03 13:53:50 | REVISION BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | ***NOTE: | | REVISIONS TO EXTERIOR OF BUILDING NEED TO BE APPROVED | | BY HISTORIC. | | | | | | 1- PLANS SUBMITTED ARE DIFFERENT FROM THE ONES THAT | | WERE APPROVED. PROVIDE COMPLETE FRAMING DETAILS AND | | SPECIFICATIONS FOR THE CLOSING OF EXISTING EXTERIOR | | OPENINGS TO SHOW COMPLIANCE WITH SEC. R301 OF 2010 | | FBC-RESIDENTIAL. | | | | 2- PLANS SHOW REMOVING PORTION OF EXISTING STAIRWAY | | WALLS TO ALLOW FOR NEW IRON HAND-RAILINGS. AND NEW | | OPENING FOR HALF BATHROOM ENTRANCE. THESE WALLS SEEM TO | | BE BEARING WALLS. PROVIDE COMPLETE ENGINEERING | | ANALYSIS, DETAILS AND SPECIFICATIONS TO SHOW THAT | | STRUCTURE IS GOING TO BE STRUCTURALLY SOUND. SEC. R301 | | OF 2010 FBC AND SEC. 107.2.1.3 OF CITY AMENDMENTS TO | | FBC. | | | | 3- PROVIDE COMPLETE CONSTRUCTION DETAILS AND | | SPECIFICATIONS FOR THE NEW HANDRAIL/GUARDRAIL TO SHOW | | COMPLIANCE WITH SEC. R311.7.7 AND THE LIVE LOADS AS | | REQUIRED BY TABLE R301.5 OF 2010 FBC-RESIDENTIAL. | | | | 4- PROVIDE DIMENSIONS FOR ALTERATIONS ON BEDROOM #3 TO | | SHOW COMPLIANCE WITH SEC. R304 OF 2010 FBC-RESIDENTIAL. | | | | | | ***NOTE: NEED A/C AND PLUMBING PERMITS. | | | | | | ****REMAINDER: THE FOLLOWING INFORMATION REQUESTED ON | | PROVISO NEED TO BE PROVIDED. | | | | 1- PROVIDE PRODUCT APPROVAL FOR EXTERIOR DOORS (AS | | REQUESTED ON PROVISO. (SEE APPROVED PLANS). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-11-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-11-13 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-11-13 |
Time |
17:15 |
Sent To |
|
|
Notes |
2013-11-13 17:19:39 | | | ***NOTE: PENDING HISTORICAL APPROVAL TO PASS BUILDING | | STOP. JG. | | | | | | ****REMAINDER: THE FOLLOWING INFORMATION REQUESTED ON | | PROVISO NEED TO BE PROVIDED. | | | | 1- PROVIDE PRODUCT APPROVAL FOR EXTERIOR DOORS (AS | | REQUESTED ON PROVISO. (SEE APPROVED PLANS). | | | | 2- PROVIDE COMPLETE INFORMATION FOR A/C UNDER A | | SEPARATE PERMIT. (NO INFORMATION SUBMITTED YET). | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-09-26 |
|
|
Cont ID |
|
Sent By |
GOMEZ |
Date |
2013-09-26 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-09-26 |
Time |
09:26 |
Sent To |
|
|
Notes |
2013-09-26 09:32:10 | RESIDENTIAL (R3) REVISION, BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1-ENERGY CALCULATIONS SUBMITTED: | | A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | INCLUDING THE CORRECT BUILDER'S NAME. SEC. 103.2.1.1.2 | | OF 2010 FBC-ENERGY CONSERVATION. | | | | B) PROVIDE MANUFACTURER'S DOCUMENTATION SHOWING THE | | WINDOWS U-FACTOR AND SHGC FACTOR AS SPECIFIED ON ITEM | | #7(A). SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION. | | | | C) CALCULATIONS NEED TO BE CERTIFIED AND DATED AT THE | | BOTTOM OF THE FORM BY THE PERSON WHO PREPARED THEM. | | SEC. 405.4.2 OF 2010 FBC-ENERGY CONSERVATION. | | | | D) ITEM #9(A) SPECIFIES R-13 IN EXTERIOR WALLS. TYPICAL | | WALL DETAIL ON FLOOR PLANS SUBMITTED SPECIFY R-11. | | REVISE AS REQUIRED TO MATCH. SEC. 103.2.2 OF 2010 | | FBC-ENERGY CONSERVATION. | | | | E) REVISE THE OVERHANG DEPTH AND SEPARATION SPECIFIED | | FOR THE WINDOWS ON PAGE 4 OF 6 TO MATCH HOUSE. | | | | ***NOTE: THIS IS A 2 STORY HOUSE WITH FLAT ROOF AND NO | | OVERHANGS. | | | | 2- PLANS SUBMITTED NEED TO BE SIGNED AND DATED BY THE | | PERSON RESPONSIBLE FOR THE DESIGN. SEC. 107.2.1 CITY | | AMENDMENTS TO FBC. | | | | | | ****REMAINDER: THE FOLLOWING INFORMATION NEED TO BE | | PROVIDED. | | | | 1- PROVIDE PRODUCT APPROVAL FOR EXTERIOR DOORS (AS | | REQUESTED ON PROVISO. (SEE APPROVED PLANS). | | | | 2- PROVIDE COMPLETE INFORMATION FOR A/C UNDER A | | SEPARATE PERMIT. (NO INFORMATION SUBMITTED YET). | | | | | | ********* PLEASE PROVIDE A RESPONSE LETTER ADDRESSING | | EACH COMMENT TO EXPEDITE THE REVIEW PROCESS******** | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2014-10-31 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-10-31 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-10-31 |
Time |
16:55 |
Sent To |
|
|
Notes |
2014-10-31 16:58:44 | 10/31/2014 | | PROJECT: | | PERMIT#: 14080234 | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | ELECTRICAL PLAN REVIEW | | ACTION: APPROVED WITH EXCEPTION. | | | | 1) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL | | 314 AND 315. INTERCONNECTED SMOKE DETECTORS ARE NOTED | | ON THE PLAN. HOWEVER WHEN THERE IS GAS OR A FIREPLACE | | THERE NEEDS TO BE CO DETECTORS WITH 10' OF SLEEPING | | AREAS. PLEASE COMPLY WITH FBC-R 314-315 | | | | 2) ALL NEW GENERAL PURPOSE OUTLETS MUST BE TAMPER | | RESISTANT AND AFCI PROTECTED. NEC 210.12, 406.11. | | | | 3) RECEPTACLES SHALL BE INSTALLED SUCH THAT NO POINT | | MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY WALL | | SPACE IS MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE | | OUTLET. NEC 210.52(A)(1) | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | 561-805-6717 OR [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2013-10-23 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2013-10-23 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2013-10-23 |
Time |
15:40 |
Sent To |
|
|
Notes |
2013-10-23 16:13:09 | IN ADDITION TO OTHER DISCREPANCIES NOTE NOTED, A FEW | | CHANGES AND CORRECTIONS WILL HAVE TO TAKE PLACE ON THE | | JOB FOR SUCCESSFUL INSPECTIONS: | | 1. THE PLANS CURRENTLY CALL FOR AFCI ONLY IN THE | | BEDROOMS, NEC 2008 STATES DIFFERENTLY. | | 2. TAMPER-RESISTANT RECEPTACLES SHALL BE REQUIRED | | THROUGH OUT THE HOME. | | 3. ALL EXTERIOR RECEPTACLE SHALL BE RATED "WR" | | 4. DUE TO THE GAS FIRE PLACE, CARBON MONOXIDE DETECTORS | | SHALL BE REQUIRED WITHIN 10' OF THE SLEEPING AREAS. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
6 |
Status |
P |
Date |
2014-06-03 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-06-03 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-06-03 |
Time |
09:19 |
Sent To |
|
|
Notes |
2014-06-03 09:20:07 | APPLICANT SUBMITTED COA AS REQUIRED. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
5 |
Status |
F |
Date |
2014-05-06 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-05-06 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-05-06 |
Time |
11:35 |
Sent To |
|
|
Notes |
2014-05-06 11:35:51 | FILED UNDER SMALL FAILED M | 2014-05-06 11:35:14 | COMMENTS REGARDING WINDOWS FROM PREVIOUS REVIEWS NOT | | RESOLVED. REQUIRES FULL COA APPLICATION. | | | | CONTACT FRIEDERIKE MITTNER AT 822-1457 WITH QUESTIONS. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
4 |
Status |
F |
Date |
2014-03-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-03-11 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-03-11 |
Time |
10:22 |
Sent To |
B |
|
Notes |
2014-03-11 10:22:40 | COMMENTS REGARDING WINDOWS FROM PREVIOUS REVIEWS NOT | | RESOLVED. REQUIRES FULL COA APPLICATION. | | | | CONTACT FRIEDERIKE MITTNER AT 822-1457 WITH QUESTIONS. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
F |
Date |
2014-01-02 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2014-01-02 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2014-01-02 |
Time |
12:05 |
Sent To |
|
|
Notes |
2014-01-02 12:06:39 | COMMENTS REGARDING WINDOWS FROM PREVIOUS REVIEWS NOT | | RESOLVED. REQUIRES FULL COA APPLICATION. | | | | CONTACT FRIEDERIKE MITTNER AT 822-1457 WITH QUESTIONS. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2013-11-07 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-11-07 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-11-07 |
Time |
16:35 |
Sent To |
|
|
Notes |
2013-11-07 16:37:26 | COMMENTS STILL NOT ADDRESSED FROM FIRST SUBMITTAL. NEED | | CLEAR ELEVATIONS SHOWING WINDOW LOCATIONS, STYLE, SIZE. | | IF ANY ARE BEING ENCLOSED. CONFIRMATION ALL PORCH | | WINDOWS ARE STAYING AS INDICATED ON PLAN. NO SIZE | | CHANGE PERMITTED. HAD PREVIOUSLY APPROVED BROZE FRAMES, | | CLEAR GLASS 1/1 SINGLE HUNG. MULTIPLE DISCUSSIONS WITH | | DESIGNER. QUESTIONS CONTACT CITY HSITORIC PRESERVATION | | PLANNER, FRIEDERIKE MITTNER AT 822-1457. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2013-10-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-10-01 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-10-01 |
Time |
14:38 |
Sent To |
E |
|
Notes |
2013-10-01 14:41:58 | CONTRIBUTING HISTORIC PROPERTY. DRAWINGS NOT TO SCALE. | | WINDOWS MUST USE ORIGINAL OPENING SIZE. NO SLIDER | | WINDOWS. PROVIDE FRONT AND SIDE ELVATIONS SHOWING | | REMOVAL OF WINDOW AND ANY CHANGES. | | | | QUESTIONS CONTACT: FRIEDERIKE MITTNER, CITY HISTORIC | | PRESERVATION PLANNER 95610 822-1457 | 2013-09-30 10:50:16 | 9/30/13 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2014-10-31 |
|
|
Cont ID |
|
Sent By |
dhayes |
Date |
2014-10-31 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
dhayes |
Date |
2014-10-27 |
Time |
11:39 |
Sent To |
|
|
Notes |
2014-10-28 11:39:57 | SENT TO J. GOMEZ DESK. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2014-07-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-07-09 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-07-01 |
Time |
17:44 |
Sent To |
|
|
Notes |
2014-07-01 17:44:53 | SENT TO GOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2014-06-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-06-03 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-04-08 |
Time |
13:01 |
Sent To |
|
|
Notes |
2014-06-11 09:56:00 | LAST REVIEW BY HISTORIC ON 6/3/14. | 2014-04-08 13:01:59 | SENT TO J. GOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2014-03-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-03-20 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-02-27 |
Time |
07:26 |
Sent To |
|
|
Notes |
2014-03-07 16:56:48 | | | 3/7/14 RESUBMITTAL SENT TO ZONING SHELF FOR FRIEDRIKE'S | | REVIEW. JG. | 2014-02-27 07:27:11 | SENT TO J GOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-01-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-01-03 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-12-26 |
Time |
15:45 |
Sent To |
|
|
Notes |
2013-12-26 15:46:30 | REVISION RESUBMITTAL SENT TO ZONING FOR FRIEDERIKE'S | | HISTORICAL REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-11-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-11-13 |
Time |
18:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-10-24 |
Time |
18:16 |
Sent To |
|
|
Notes |
2013-10-28 11:01:02 | 10/28/13 SENT TO ZONING SHELF FOR HISTORIC REVIEW. JG. | 2013-10-24 18:16:55 | SENT TO J GOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-10-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-10-24 |
Time |
18:15 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-09-18 |
Time |
07:56 |
Sent To |
|
|
Notes |
2013-09-26 09:37:42 | 9/26/13 REVISION SENT TO R12 SHELF FOR REVIEW. JG. | 2013-09-20 07:58:23 | SENT TO GOMEZ |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2014-03-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-03-20 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-03-20 |
Time |
13:51 |
Sent To |
|
|
Notes |
2014-03-20 13:52:50 | PROVIDE COMPLETE INFORMATION FOR MECHANICAL WORK UNDER | | A SEPARATE PERMIT. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2014-01-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-01-03 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-01-03 |
Time |
16:05 |
Sent To |
|
|
Notes |
2014-01-03 16:32:16 | REVISION MECHANICAL REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE COMPLETE A/C PLANS SHOWING ALL THE EQUIPMENT | | AND DUCTWORK. SEC. 103.2.2 OF 2010 FBC-ENERGY | | CONSERVATION. | | | | 2- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS AS | | REQUIRED BY SEC. 403.6 OF 2010 FBC-ENERGY CONSERVATION. | | ***NOTE: EQUIPMENT LISTED ON THE EQUIPMENT SIZING | | CALCULATIONS TO MATCH EQUIPMENT SHOWN ON THE A/C PLAN. | | | | 3- PLANS SUBMITTED SHOW AN A/C UNIT INSIDE AN INTERIOR | | CLOSET ON THE SECOND FLOOR AND AN AHU ON THE ROOF ABOVE | | THE KITCHEN. CLARIFY AS REQUIRED. WHY THE AHU IS | | OUTSIDE?. SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION. | | | | 4- PROVIDE COMPLETE INSTALLATION DETAILS FOR THE | | ANCHORAGE OF UNIT LOCATED ON THE ROOF AS REQUIRED BY | | SEC. M1307.2.1 OF 2010 FBC-RESIDENTIAL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
7 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2014-10-31 |
Time |
|
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2014-10-31 |
Time |
13:39 |
Sent To |
|
|
Notes |
2014-10-31 13:41:14 | *******PROVISO********** | | | | A REVISED SANITARY RISER SHALL BE ONSITE AT TIME OF | | ROUGH INSPECTION. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
F |
Date |
2014-07-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-07-09 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-07-09 |
Time |
13:55 |
Sent To |
|
|
Notes |
2014-07-09 14:00:44 | REVISION FOURTH PLUMBING REVIEW CHECKLIST. | | CODE: 2010 FBC. | | | | ***NOTE: DRAWING SUBMITTED IS THE SAME THAT WAS | | SUBMITTED BEFORE. PLUMBING RISER DIAGRAM WAS NOT | | CORRECTED. | | | | | | | | 1- PROVIDE A CORRECT AND COMPLETE PLUMBING RISER | | DIAGRAM THAT MATCHES PROPOSED MASTER BATH AND RELOCATED | | HALF BATH BELOW STAIRS. SEC. 107.3.5.3(11) OF CITY | | AMENDMENTS TO FBC. | | | | *** PLUMBING RISER DIAGRAM SUBMITTED IS INCOMPLETE AND | | IS NOT CORRECT. TO AVOID MORE CONFUSION AND DELAYS, | | PLUMBING RISER DIAGRAM MAY BE DRAWN BY THE LICENSED | | CONTRACTOR RESPONSIBLE FOR THE WORK. IF DOING SO, | | CONTRACTOR TO PROVIDE NAME, LICENSE NUMBER AND | | SIGNATURE ON PLUMBING RISER DIAGRAM. SEC. 107.2.1 CITY | | AMENDMENTS TO FBC. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES | | (561)805-6712 | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2014-04-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-04-25 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-04-25 |
Time |
15:08 |
Sent To |
|
|
Notes |
2014-04-25 15:12:54 | REVISION THIRD PLUMBING REVIEW CHECKLIST. | | CODE: 2010 FBC. | | | | | | 1- PROVIDE A CORRECT AND COMPLETE PLUMBING RISER | | DIAGRAM THAT MATCHES PROPOSED MASTER BATH AND RELOCATED | | HALF BATH BELOW STAIRS. SEC. 107.3.5.3(11) OF CITY | | AMENDMENTS TO FBC. | | | | *** PLUMBING RISER DIAGRAM SUBMITTED IS INCOMPLETE AND | | IS NOT CORRECT. TO AVOID MORE CONFUSION AND DELAYS, | | PLUMBING RISER DIAGRAM MAY BE DRAWN BY THE LICENSED | | CONTRACTOR RESPONSIBLE FOR THE WORK. IF DOING SO, | | CONTRACTOR TO PROVIDE NAME AND SIGNATURE ON PLUMBING | | RISER DIAGRAM. SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES | | (561)805-6712 | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2014-03-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-03-20 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-03-20 |
Time |
13:54 |
Sent To |
|
|
Notes |
2014-03-20 13:57:20 | REVISION SECOND PLUMBING REVIEW CHECKLIST. | | CODE: 2010 FBC. | | | | *** ORIGINAL COMMENT: | | 1- PROVIDE A CORRECT AND COMPLETE PLUMBING RISER | | DIAGRAM THAT MATCHES PROPOSED MASTER BATH AND RELOCATED | | HALF BATH BELOW STAIRS. SEC. 107.3.5.3(11) OF CITY | | AMENDMENTS TO FBC. | | | | *** PLUMBING RISER DIAGRAM SUBMITTED IS INCOMPLETE AND | | IS NOT CORRECT. TO AVOID MORE CONFUSION AND DELAYS, | | PLUMBING RISER DIAGRAM MAY BE DRAWN BY THE LICENSED | | CONTRACTOR RESPONSIBLE FOR THE WORK. | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2014-01-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2014-01-03 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2014-01-03 |
Time |
16:32 |
Sent To |
|
|
Notes |
2014-01-03 17:00:47 | REVISION PLUMBING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE A CORRECT AND COMPLETE PLUMBING RISER | | DIAGRAM THAT MATCHES PROPOSED MASTER BATH AND RELOCATED | | HALF BATH BELOW STAIRS. SEC. 107.3.5.3(11) OF CITY | | AMENDMENTS TO FBC. | | | | 2- PROVIDE DIMENSIONS FOR MASTER BATH FIXTURES TO SHOW | | COMPLIANCE WITH SEC. P2705 OF 2010 FBC-RESIDENTIAL. | | | | 3- PROVIDE DIMENSIONS FOR MASTER BATHROOM SHOWER TO | | SHOW COMPLIANCE WITH SEC. P2708 OF 2010 | | FBC-RESIDENTIAL. | | | | 4- RELOCATION OF HALF BATHROOM FIXTURES REQUIRES THE | | FIXTURES TO COMPLY WITH SEC. P2705 OF 2010 | | FBC-RESIDENTIAL. PROVIDE DIMENSIONS TO VERIFY | | COMPLIANCE WITH THE REQUIRED CLEARANCES. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2013-11-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-11-13 |
Time |
18:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-11-13 |
Time |
18:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2013-09-26 |
|
|
Cont ID |
|
Sent By |
GOMEZ |
Date |
2013-09-26 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-09-26 |
Time |
10:56 |
Sent To |
|
|
Notes |
2013-09-26 10:58:56 | RESIDENTIAL (R3) REVISION, PLUMBING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE PLUMBING RISER DIAGRAM AS REQUIRED BY SEC. | | 107.3.5.3(11) OF CITY AMENDMENTS TO FBC. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2013-10-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-10-01 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-10-01 |
Time |
14:38 |
Sent To |
|
|
Notes |
|
|