Plan Review Stops For Permit 13090470 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2013-10-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-10-10 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-10-10 |
Time |
12:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2013-03-20 |
|
|
Cont ID |
|
Sent By |
MGonzale |
Date |
2013-03-20 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2013-03-20 |
Time |
|
Sent To |
B |
|
Notes |
2013-12-20 10:08:08 | NO CONFLICTS WITH UTILITIES; HOWEVER CALL 811 BEFORE | | DIGG. | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | MOBILE: (561) 644-7301 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2013-10-21 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2013-10-21 |
Time |
13:14 |
Rev Time |
0.25 |
Received By |
mgonzale |
Date |
2013-10-21 |
Time |
09:47 |
Sent To |
|
|
Notes |
2013-10-21 09:51:12 | | | #1 NEED FENCE DETAILS (FENCE STRUCTURE) | | #2 IDENTIFY FENCE LOCATION IN ROW OR PRIVATE PROPERTY? | | #3 LARGE SURVEY DOES NOT SHOW FENCE LOCATION. | | #4 EXISTING FENCES FOR NEIGHBORS WILL REMAIN? DUAL | | FENCE / MAINTENANCE BURDEN | | #5 MASONRY FENCE FOUNDATION CONFLICTS WITH WATERMAIN. | | #6 PROVIDE CLEARANCE OK FROM COMCAST, GAS, FPL, AT&T. | | | | COMMENTS BY VINCE NOEL THRU MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | MOBILE: (561) 644-7301 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2013-09-26 |
|
|
Cont ID |
|
Sent By |
Mgonzale |
Date |
2013-09-26 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2013-09-26 |
Time |
|
Sent To |
Z |
|
Notes |
2013-09-26 15:30:27 | FAILED: | | | | #1 PROVIDE 1'=20' SURVEY WITH WALL AND FOOTER OUTLINED. | | (FULL SIZE 24"X36") | | | | #2 PROVIDE ALTERNATE WALL DESIGN WHERE 8" WATERMAIN IS | | CROSSING. | | | | #3 SHOW CROSS SECTION OF WATERMAIN WITH WATERMAIN AND | | CLEARANCES, | | | | #4 WALL AND FOOTING SHOULD BE CLEAR OF PRIVATE | | PROPERTY. | | | | #5 PROVIDE METAL FENCE DETAILS AND POST LOCATIONS. | | | | RESUBMIT. | | | | MANUEL JULIAN GONZALEZ | | ENGINEERING PROJECT COORDINATOR | | ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | MOBILE: (561) 644-7301 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2013-12-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-12-20 |
Time |
17:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-12-18 |
Time |
17:13 |
Sent To |
|
|
Notes |
2013-12-18 17:16:29 | SENT TO ENGINEERING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-10-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-10-21 |
Time |
17:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-10-10 |
Time |
12:53 |
Sent To |
|
|
Notes |
2013-10-10 12:52:53 | SENT TO ENGINEERING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-10-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-10-10 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-09-17 |
Time |
15:12 |
Sent To |
|
|
Notes |
2013-09-17 15:14:49 | SENT TO ZONING SHELF FOR REVIEW. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2013-09-27 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2013-09-27 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
llouie |
Date |
2013-09-27 |
Time |
14:19 |
Sent To |
B |
|
Notes |
2013-09-27 14:21:15 | 9/27/13 - ZONING REVIEW NOT REQUIRED. FENCE LOCATED IN | | PUBLIC RIGHT-OF-WAY. STRUCTURES IN ROW NOT REGULATED BY | | CHAPTER 94 OF THE CODE. | 2013-09-23 11:40:04 | 9/23/13 - FENCE/WALL BEING BUILT IN THE ROW ZONING | | SENDIND TO ENG FOR REVIEW AND APPROVAL. |
|
|