Plan Review Details - Permit 13081204
Plan Review Stops For Permit 13081204
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-10-25 Cont ID  
Sent By rmcdouga Date 2013-10-12 Time 06:42 Rev Time 0.00
Received By rmcdouga Date 2013-10-11 Time 06:58 Sent To Z
Notes
2013-10-12 06:55:59BUILDING PROVISO
  
 SUBMIT A SIGNED AND SEALED LETTER FROM THE DESIGNER OF
 RECORD, JOHN HOLT, STATING THAT HE HAS REVIEWED AND
 APPROVED THE ES WINDOWS (NOA # 12-0223.42), FRENCH DOOR
 (NOA # 12-0308.40), THE 3M FOAM ROOF TILE ADHESIVE
 AH-160 (NOA# 12-0228.18) AND THE MULE-HIDE SELF-ADHERED
 ROOF SYSTEM (NOA # 12-0815.09) PRODUCT APPROVALS AS
 REQUIRED BY CITY AMENDMENTS 107.3.4.1.
  
 SUBMIT TWO 405-10 ENERGY FORMS THAT HAVE BEEN SIGNED BY
 THE PERSON THAT PREPARED THEM AND THE OWNER/AGENT. FBC
 ENERGY SECTION 405.4

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-09-11 Cont ID  
Sent By rmcdouga Date 2013-09-11 Time 18:00 Rev Time 0.00
Received By rmcdouga Date 2013-09-11 Time 09:32 Sent To  
Notes
2013-09-11 11:47:122010 FBC
  
 1) THE PERMIT APPLICATION INDICATES THE ADDITION IS TO
 BE STORAGE AND THE PLANS DO NOT SPECIFY THE ROOM USE.
 BASED ON THE PLANS THAT WERE SUBMITTED THE ADDITION
 APPEARS TO BE A BEDROOM OR COULD BE USED AS A BEDROOM
 BY AN OWNER IN THE FUTURE. PLEASE CLARIFY BY LABELING
 THE ROOM ON THE PLANS.
  
 2) THE PLANS SPECIFY THAT THE SPACE WILL BE
 CONDITIONED. SUBMIT TWO COPIES OF ENERGY CALCULATIONS
 FOR THE BUILDING. FBC ENERGY CONSERVATION SECTIONS
 101.4.3 , 101.4.5
  
 3) SHOW COMPLIANCE WITH FBCR 318 FOR TERMITE
 PROTECTION.
  
 4) FBC R403.1.4 REQUIRES ALL EXTERIOR FOOTINGS TO BE
 PLACED AT LEAST 12 INCHES BELOW GRADE AND FBC R317.1
 (5) REQUIRES PROTECTION OF WOOD AND WOOD PRODUCTS FROM
 DECAY FOR WALL FRAMING AND SHEATHING AT THE EXTERIOR OF
 A BUILDING HAVING A CLEARANCE OF LESS THAN 6" FROM THE
 GROUND. THE 16" DEEP FOOTING SPECIFIED ON THE PLANS
 WILL ONLY PROVIDE 4" FROM THE GROUND. SPECIFY HOW THIS
 REQUIREMENT WILL BE ADDRESSED.
  
 5) SHOW COMPLIANCE WITH FBCR 318.6 WHICH REQUIRES
 GUTTERS AND DOWNSPOUTS AT THE REAR OF THE STRUCTURE
 WITH NO EAVE PROJECTION WHERE THE RAIN WATER FROM THE
 ROOF IS DISCHARGED.
  
 6) SHOW COMPLIANCE WITH FBCR 806 FOR REQUIRED ATTIC
 VENTILATION.
  
 7) PROVIDE A STRUCTURAL DETAIL SHOWING HOW THE 4 X 10
 WOOD BEAM AT THE COVERED PORCH IS TO BE NOTCHED INTO
 THE CORNERS AT EACH END (INCLUDING THE EXISTING
 CORNER). SPECIFY THE NUMBER OF FRAMING MEMBERS REQUIRED
 FOR BEARING AND THE REQUIRED STRAPS AND CONNECTORS FOR
 UPLIFT AND LATERAL FORCES. FBC R301.1
  
 8) PLEASE CLARIFY IF THE (3) #5 BARS IN THE FOOTING ARE
 TO BE DOWELED INTO THE EXISTING FOOTING. FBC R301.1
  
 9) PROVIDE A STRUCTURAL DETAIL OF THE PARAPET
 CONSTRUCTION. SHOW ALL CONNECTORS REQUIRED TO ACHIEVE A
 CONTINUOUS LOAD PATH. FBC R301.1
  
 10) PRODUCT APPROVALS REQUIRED BY DCA RULE 9N-3 ARE
 REQUIRED TO BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD FOR THE PROJECT. CITY AMENDMENTS 10
  
 11) SUBMIT (2) COPIES OF PRODUCT APPROVALS FOR THE NEW
 EXTERIOR DOOR, THE ROOF TILE AND THE SIMPSON CONNECTORS
 AS REQUIRED BY DCA RULE 9N-3.
  
 12) SPECIFY WHICH METHOD OF ATTACHMENT LISTED IN THE
 ROOF TILE PRODUCT APPROVAL WILL BE USED TO INSTALL IT.
 IF AN ADHESIVE IS USED, SUBMIT TWO COPIES OF THE
 PRODUCT APPROVAL. FBC R905.1
  
 13) SPECIFY THE APPROVED ASSEMBLY, INSULATION TYPE,
 FASTENING OPTION AND MAXIMUM DESIGN PRESSURE FROM THE
 MULE- HIDE ROOFING PRODUCT APPROVAL (NOA # 12-0815.09)
 THAT WILL BE USED. IF ENHANCED FASTENING OF THE BASE
 SHEET IS REQUIRED TO MEET THE UPLIFT PRESSURE
 REQUIREMENTS OF THE PERIMETER AND CORNER ROOF AREAS
 SUBMIT TWO SETS OF SIGNED AND SEALED RAS 117
 CALCULATIONS IN ACCORDANCE WITH LIMITATION #7 ON PAGE
 25 OF THE NOA. FBC R905.1
  
 14) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW THE
 REVIEW COMMENTS HAVE BEEN ADDRESSED. THIS WILL AID IN
 SPEEDING REVIEW TIMES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-10-12 Cont ID  
Sent By rmcdouga Date 2013-10-12 Time 06:42 Rev Time 0.00
Received By rmcdouga Date 2013-10-10 Time 19:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-09-11 Cont ID  
Sent By rmcdouga Date 2013-09-11 Time 11:04 Rev Time 0.00
Received By rmcdouga Date 2013-09-11 Time 11:04 Sent To  
Notes
2013-09-11 11:04:322010 FBC / 2008 NEC
  
 DENIED BY ELECTRICAL
  
 1) PROVIDE THE TOTAL LOAD CALCULATIONS FOR THE EXISTING
 POOL CABANA AND THE ADDITION. NEC 220.83 (B) AND CITY
 AMENDMENTS 107.3.5.3
  
 2) PROVIDE A PANEL SCHEDULE FOR THE 100 AMP PANEL
 SERVICING THE POOL CABANA. NEC 408.4 AND CITY
 AMENDMENTS 107.3.5.3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2013-10-25 Cont ID  
Sent By rmcdouga Date 2013-10-25 Time 15:33 Rev Time 0.00
Received By rmcdouga Date 2013-10-25 Time 15:33 Sent To  
Notes
2013-10-25 15:34:17PLANS RE-STAMPED BY FRIEDERIKE MITNER.
2013-10-23 08:59:01NEW PLANS NEEDS RESTAMP.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2013-08-30 Cont ID  
Sent By fmittner Date 2013-08-30 Time 13:14 Rev Time 0.00
Received By fmittner Date 2013-08-30 Time 13:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-10-22 Cont ID  
Sent By rmcdouga Date 2013-10-22 Time 18:07 Rev Time 0.00
Received By rmcdouga Date 2013-10-16 Time 11:20 Sent To  
Notes
2013-10-16 11:20:47INCOMING SENT TO R. MCDOUGALS DESK. JWITMER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-10-12 Cont ID  
Sent By rmcdouga Date 2013-10-12 Time 07:05 Rev Time 0.00
Received By rmcdouga Date 2013-10-08 Time 08:46 Sent To  
Notes
2013-10-09 08:47:00SENT TO MCDOUGAL'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-09-11 Cont ID  
Sent By rmcdouga Date 2013-09-11 Time 18:00 Rev Time 0.00
Received By rmcdouga Date 2013-09-03 Time 09:24 Sent To  
Notes
2013-09-04 09:25:24R03

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2013-10-22 Cont ID  
Sent By rmcdouga Date 2013-10-22 Time 18:07 Rev Time 0.00
Received By rmcdouga Date 2013-10-12 Time 07:06 Sent To  
Notes
2013-10-12 07:06:26MU2013-22152 -NO FEES DUE - ADDITION OF 328 SQFT TO
 POOL CABANA.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-09-11 Cont ID  
Sent By rmcdouga Date 2013-09-11 Time 09:32 Rev Time 0.00
Received By rmcdouga Date 2013-09-11 Time 09:32 Sent To  
Notes
2013-09-11 09:38:19THE NEW ADDITION IS NOT LABELED AS STORAGE AND APPEARS
 TO BE A BEDROOM WHICH IS HABITABLE SPACE RATHER THAN
 STORAGE AS INDICATED ON THE PERMIT APPLICATION.
 THEREFORE, THE PLANS ARE REQUIRED TO BE REVIEWED BY
 PALM BEACH COUNTY FOR IMPACT FEES.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2013-10-10 Cont ID  
Sent By rmcdouga Date 2013-10-10 Time 19:10 Rev Time 0.00
Received By rmcdouga Date 2013-10-10 Time 19:10 Sent To  
Notes
2013-10-10 19:14:22CONTRACTOR HAS REQUESTED THAT MECHANICAL BE UNDER A
 SEPARATE PERMIT. SEPARATE PERMIT, APPLICATION AND
 REVIEW IS REQUIRED (PERMIT FEES WILL BASED ON VALUE OF
 MECHANICAL WORK).

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-09-11 Cont ID  
Sent By rmcdouga Date 2013-09-11 Time 09:41 Rev Time 0.00
Received By rmcdouga Date 2013-09-11 Time 09:41 Sent To  
Notes
2013-09-11 10:04:212010 FBC
  
 DENIED BY MECHANICAL
  
 A NEW AIR HANDLER AND CONDENSER UNIT ARE SHOWN ON THE
 PLANS.
  
 1) SUBMIT TWO SETS OF EQUIPMENT SIZING CALCULATIONS IN
 ACCORDANCE WITH ACCA MANUAL J FOR THE HVAC EQUIPMENT.
 FBCR M1401.3
  
 2) SUBMIT TWO SETS OF MECHANICAL PLANS. FBCR M1601.1
 SHOW THE DUCT LOCATION AND SIZE. SPECIFY THE SUPPLY
 GRILL SIZES AND CFMS AT EACH DROP. SPECIFY THE RETURN
 LOCATIONS, DUCT AND GRILL SIZES AND SHOW COMPLIANCE
 WITH FBC M1602.4 FOR BALANCED RETURN AIR.
  
 3) PROVIDE AN EQUIPMENT SCHEDULE ON THE MECHANICAL
 PLANS.
  
 4) PROVIDE AN ANCHORING DETAIL CAPABLE OF RESISTING THE
 APPLICABLE WIND PRESSURES FOR THE EXTERIOR EQUIPMENT.
 FBCR M1307.2.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2013-10-12 Cont ID  
Sent By rmcdouga Date 2013-10-12 Time 06:56 Rev Time 0.00
Received By rmcdouga Date 2013-10-12 Time 06:56 Sent To  
Notes
2013-10-12 07:04:43ROOFING PRODUCT APPROVALS SUBMITTED:
  
 MULE-HIDE SELF-ADHERED ROOF SYSTEM (NOA # 12-0815.09)
 MISSION BARREL ROOFING TILE (NOA # 12-0529.12)
 3M 2-COMPONENT FOAM ROOF TILE ADHESIVE AH-160 (NOA #
 12-0228.18)
 POLYGLASS POLYSTICK TILE UNDERLAYMENT (NOA # 12-0713.02

Review Stop Z ZONING
Rev No 2 Status P Date 2013-10-25 Cont ID  
Sent By rmcdouga Date 2013-10-25 Time 15:41 Rev Time 0.00
Received By rmcdouga Date 2013-10-25 Time 15:35 Sent To  
Notes
2013-10-25 15:35:36PLANS RE-STAMPED BY FRIEDERIKE MITNER.

Review Stop Z ZONING
Rev No 1 Status P Date 2013-08-30 Cont ID  
Sent By fmittner Date 2013-08-30 Time 13:14 Rev Time 0.00
Received By fmittner Date 2013-08-30 Time 13:14 Sent To  
Notes
***NONE***