|
 |
 |
 |
 |
 |
Plan Review Details - Permit 13080997
Plan Review Stops For Permit 13080997 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2013-08-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-08-27 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-08-27 |
Time |
06:57 |
Sent To |
|
|
Notes |
2013-08-27 07:59:45 | BUILDING PLAN REVIEW | | PERMIT: 13080997 | | ADD: 622 N FLAGLER DR # 204 | | CONT: HEDRICK BROTHERS | | TEL: (561)689-8880 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | DATE: TUESDAY AUGUST 27/ 2013 | | ACTION: BUILDING PROVISO | | | | FLOORING: IF JUST REPLACING FLOOR TILE IT IS CONSIDERED | | A REPAIR, IF THE WHOLE FLOOR IN THE ROOM IS BEING | | REPLACE THEN IT IS CONSIDERED NEW CONSTRUCTION AND WILL | | NEED TO COMPLY WITH: | | 1A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | 1B) FBC-B 2010 603.2 EXCEPTION (1) TILE FLOORING | | FLOOR INSULATION PLACED BETWEEN TWO LAYERS OF | | NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING | | AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX | | OF NOT MORE THAN 100. | | | | 1C) FBC-B 2010 603.2 EXCEPTION 2 WOOD FLOORS | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | FBC-B 2010 | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2013-09-11 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-09-11 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-09-11 |
Time |
10:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-09-04 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-09-04 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-09-04 |
Time |
13:22 |
Sent To |
|
|
Notes |
2013-09-04 13:37:23 | FIRST REVIEW -9-4-13 | | 1.PROVIDE PANEL SCHEDULE PER NEC 408.4 | | 2. ALL NEW OUTLETS TO BE TAMPER RESISTANT AND AFCI | | PROTECTED PER NEC 406.11 AND 210.12B | | 3. SHOW CIRCUITRY AND ROOM NAMES FOR CLARITY ON | | ELECTRICAL PLANS | | 4. PROVIDE LOAD CALCS WITH ALL ADDITIONAL APPLIANCES, | | FIXTURES AND CIRCUITS PER NEC 220 | | 5. PROVIDE SMOKE ALARMS PER FLORIDA RESIDENTIAL CODE | | SECTION 314 IF NOT ALREADY EXISTING | | END OF REVIEW - VB | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2013-08-28 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-08-28 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-08-28 |
Time |
10:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-09-11 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-09-11 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-09-11 |
Time |
09:53 |
Sent To |
|
|
Notes |
2013-09-11 10:18:41 | RETURNED TO J WITMER DH | 2013-09-11 09:54:10 | EXPEDITED, INCOMING SENT TO D HARVEY DESK. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-09-04 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-09-04 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-09-04 |
Time |
13:40 |
Sent To |
|
|
Notes |
2013-08-26 14:43:00 | SENT TO B33 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2013-09-04 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-09-04 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-09-04 |
Time |
10:42 |
Sent To |
|
|
Notes |
2013-09-04 10:55:29 | ****PROVISO FOR SHOWER**** | | 417.5.2.5 SHEET-APPLIED, LOAD-BEARING, BONDED, | | WATERPROOF MEMBRANES. | | SHEET-APPLIED, LOAD-BEARING, BONDED, WATERPROOF | | MEMBRANES SHALL MEET REQUIREMENTS OF ANSI A118.10 AND | | SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S | | INSTALLATION INSTRUCTIONS. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2013-08-28 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2013-08-28 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2013-08-28 |
Time |
14:27 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |