Plan Review Stops For Permit 13080797 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2013-10-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-10-02 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-10-02 |
Time |
11:00 |
Sent To |
|
|
Notes |
2013-10-02 11:32:26 | BUILDING PLAN REVIEW | | PERMIT: 13080797 | | ADD: 513 CLEMATIS ST UNITS # 201, 203, & 205 | | CONT: LARRY B. ROWE | | TEL: (561)835-17999 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE:OCT 02/ 2013 | | ACTION: PROVISO | | | | 1) EGRESS COURT FOR THE REAR EXTERIOR STAIR IS TO | | COMPLY WITH: | | 2010 FBC-B 1027 EGRESS COURTS | | 1027.2 EXIT DISCHARGE CAPACITY. | | THE CAPACITY OF THE EXIT DISCHARGE SHALL BE NOT LESS | | THAN THE REQUIRED DISCHARGE CAPACITY OF THE EXITS BEING | | SERVED. | | | | 1027.3 EXIT DISCHARGE LOCATION. | | EXTERIOR BALCONIES, STAIRWAYS AND RAMPS SHALL BE | | LOCATED AT LEAST 10 FEET (3048 MM) FROM ADJACENT LOT | | LINES AND FROM OTHER BUILDINGS ON THE SAME LOT UNLESS | | THE ADJACENT BUILDING EXTERIOR WALLS AND OPENINGS ARE | | PROTECTED IN ACCORDANCE WITH SECTION 705 BASED ON FIRE | | SEPARATION DISTANCE. | | | | 1027.4 EXIT DISCHARGE COMPONENTS. | | EXIT DISCHARGE COMPONENTS SHALL BE SUFFICIENTLY OPEN TO | | THE EXTERIOR SO AS TO MINIMIZE THE ACCUMULATION OF | | SMOKE AND TOXIC GASES. | | | | 1027.5 EGRESS COURTS. | | EGRESS COURTS SERVING AS A PORTION OF THE EXIT | | DISCHARGE IN THE MEANS OF EGRESS SYSTEM SHALL COMPLY | | WITH THE REQUIREMENTS OF SECTION 1027. | | | | 1027.5.1 WIDTH. | | THE WIDTH OF EGRESS COURTS SHALL BE DETERMINED AS | | SPECIFIED IN SECTION 1005.1, BUT SUCH WIDTH SHALL NOT | | BE LESS THAN 44 INCHES (1118 MM), EXCEPT AS SPECIFIED | | HEREIN. EGRESS COURTS SERVING GROUP R-3 AND U | | OCCUPANCIES SHALL NOT BE LESS THAN 36 INCHES (914 MM) | | IN WIDTH. THE REQUIRED WIDTH OF EGRESS COURTS SHALL BE | | UNOBSTRUCTED TO A HEIGHT OF 7 FEET (2134 MM). | | | | WHERE AN EGRESS COURT EXCEEDS THE MINIMUM REQUIRED | | WIDTH AND THE WIDTH OF SUCH EGRESS COURT IS THEN | | REDUCED ALONG THE PATH OF EXIT TRAVEL, THE REDUCTION IN | | WIDTH SHALL BE GRADUAL. THE TRANSITION IN WIDTH SHALL | | BE AFFECTED BY A GUARD NOT LESS THAN 36 INCHES (914 MM) | | IN HEIGHT AND SHALL NOT CREATE AN ANGLE OF MORE THAN 30 | | DEGREES (0.52 RAD) WITH RESPECT TO THE AXIS OF THE | | EGRESS COURT ALONG THE PATH OF EGRESS TRAVEL. IN NO | | CASE SHALL THE WIDTH OF THE EGRESS COURT BE LESS THAN | | THE REQUIRED MINIMUM. | | | | 1027.5.2 CONSTRUCTION AND OPENINGS. | | WHERE AN EGRESS COURT SERVING A BUILDING OR PORTION | | THEREOF IS LESS THAN 10 FEET (3048 MM) IN WIDTH, THE | | EGRESS COURT WALLS SHALL HAVE NOT LESS THAN 1-HOUR | | FIRE-RESISTANCE-RATED CONSTRUCTION FOR A DISTANCE OF 10 | | FEET (3048 MM) ABOVE THE FLOOR OF THE COURT. OPENINGS | | WITHIN SUCH WALLS SHALL BE PROTECTED BY OPENING | | PROTECTIVES HAVING A FIRE PROTECTION RATING OF NOT LESS | | THAN 3/4 HOUR. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-09-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-09-24 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-09-24 |
Time |
11:20 |
Sent To |
|
|
Notes |
2013-09-24 12:43:52 | BUILDING PLAN REVIEW | | PERMIT: 13080797 | | ADD: 513 CLEMATIS ST UNITS # 201, 203, & 205 | | CONT: LARRY B. ROWE | | TEL: (561)835-17999 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE:SEPT 24/ 2013 | | ACTION: DENIED | | | | 1) COMPLIED. | | | | 2) CITY OF WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 | | EDITION.107.3.5.1.1. MINIMUM CRITERIA FOR COMMERCIAL | | PLAN REVIEW: | | 2A) MINIMUM BUILDING TYPE | | 2B)COMPLIED | | 2C) COMPLIED. | | 2D) SEMI-COMPLIED. | | 2D)(1) LIFE SAFETY PLAN THE SECOND STORY IS SHOWN, BUT | | THE JOBSITE VISIT SHOWED THE BACK EXTERIOR STAIR WAY | | LEADING INTO A COURTYARD WITH NO EXIT. MAKING THIS A | | SINGLE EXIT FROM THE FRONT SET OF STAIRS. FBC-B TABLE | | 1021.2 STORIES WITH ONE- EXIT TRAVEL DISTANCE LIMIT 75 | | FEET. THE COURTYARD WILL NEED TO LEED TO A PUBLIC WAY. | | AT THE JOBSITE VISIT THE CONTRACTOR AND OWNER INDICATED | | ON THE WEST SIDE OF THE BUILDING WHERE THEY WERE GOING | | TO OPEN FRONTAGE TO CLEMATIS ST FOR THE SECOND MEANS OF | | EGRESS TO THE PUBLIC WAY, ALSO REVIEW FBC-B 1027.5 | | EGRESS COURT REQUIREMENTS. PLEASE PROVIDE A SITE PLAN | | WITH THE EGRESS FOR THE BACK EXTERIOR STAIR THRU THE | | COURTYARD LEADING TO THE PUBLIC WAY. | | | | 2D)(2)SEMI-COMPLIED.9/26/13 SUBMITTED 45 MINUTE RATED | | GLASS BLOCK FOR WINDOWS WITHIN 10' OF EXTERIOR STIAR. | | THE SECOND ISSUE WHEN THE EGRESS FROM THE COURTYARD TO | | THE PUBLIC WAY OCCURS IS THE DISTANCE BETWEEN THE TOP | | OF THE 2 STAIRWAYS IS NOT 1/2 THE OF THE LENGTH OF THE | | MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR | | AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN | | DIAGONAL DISTANCE PER FBC-B 1015.2.1. NOTE WHEN YOU | | FIGURE THE OVERALL DIAGONAL OF THE BUILDING WITHOUT THE | | TERRRACE WE ARE WITHIN ONE FOOT OF COMPLIANCE. AT SOME | | TIME SOMEONE HAS CUT IN A EXTERIOR DOORWAY AND CREATED | | A ROOF TOP TERRACE MAKING THE OVER ALL DIAGONAL | | DISTANCE A GREATER DISTANCE FOR THE STAIRS TO BE APART, | | AND NOT CODE COMPLIANT. | | | | EVEN IF YOU LOOK AT UNIT 203 THE FURTHEST POINT ON THE | | TERRACE THE TRAVEL DISTANCE TO THE BOTTOM OF THE STAIRS | | IS OVER 75 FEET. THE FURTHEST DISTANCE FROM THE | | FURTHEST POINT ON THE TERRACE TO THE TOP LANDING AT THE | | BACK STAIR IS APPROX. 68 FEET, OUTSIDE OF THE BUILDING | | THE BUILDING OFFICIAL WILL APPROVE THIS DISTANCE BUT | | THE BATHROOM WINDOW IN UNIT DOES NEED TO BE 3/4 HOUR | | FIRE RATED, IT IS WITHIN 10 FEET OF THE EXTERIOR STAIR, | | FBC-B 1026.6 AND THE EXTERIOR DOOR WILL NEED TO BE 1 | | HOUR FIRE RATED. | | | | 3) LIFE SAFETY PLAN SHALL INCLUDE THE FOLLOWING | | INFORMATION: | | 3A COMPLIED. | | 3B) COURTYARD 2010 FBC-B 1027.5. | | 3C) STAIRWELL WALL RATINGS, 2010 FBC-B 1022.1, & 2010 | | EXISTING BUILDING CODE 912.5.3 EXCEPTION. | | 3D) 2010 EXISTING BUILDING CODE 912.4.4. HANDRAILS | | SHALL COMPLY WITH 705.9 IN AREAS OF CHANGE OF | | OCCUPANCY. HANDRAILS SHALL BE THE FULL LENGTH OF THE | | RUN OF THE STEPS ON AT LEAST ONE SIDE. | | 3E) 2010 EXISTING BUILDING CODE 912.8 ACCESSIBILITY. | | 3F) 2010 FBC-ACCESSIBILITY CODE 202.4.1 | | DISPROPORTIONATE COST. | | | | 4) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-09-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-09-09 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-09-09 |
Time |
10:52 |
Sent To |
|
|
Notes |
2013-09-09 12:26:48 | BUILDING PLAN REVIEW | | PERMIT: 13080797 | | ADD: 513 CLEMATIS ST UNITS # ???? | | CONT: LARRY B. ROWE | | TEL: (561)835-17999 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1SST REVIEW | | DATE: SEPT 09/ 2013 | | ACTION: DENIED | | | | 1) CITY OF WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION. | | 107.1. THE DESIGNER OF RECORD (CONTRACTOR) IS TO SIGN | | THE PLAN, PRINT THEIR NAME AND LICENSE NUMBER ON THE | | PLAN. | | | | 2) CITY OF WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 | | EDITION.107.3.5.1.1. MINIMUM CRITERIA FOR COMMERCIAL | | PLAN REVIEW: | | 2A) MINIMUM BUILDING TYPE | | 2B) FIRE SPRINKLERRED OR NOT? | | 2C) TYPE OF OCCUPANCY, THERE IS NO COMMERCIAL, | | ASSEMBLY, BUSNIESS, MERCANTILE OR LIVE/WORK UNITS? | | 2D) LIFE SAFETY PLAN | | | | 3) LIFE SAFETY PLAN SHALL INCLUDE THE FOLLOWING | | INFORMATION: | | 3A) OCCUPANCY 2010 FBC-B 302.1., TABLE 508.4 & TABLE | | 707.3.9. | | 3B ) MEANS OF EGRESS, COMMON PATH OF TRAVEL 2010 FBC-B | | 1014.3 | | 3C) STAIRWELL WALL RATINGS, 2010 FBC-B 1022.1, & 2010 | | EXISSTING BUILDING CODE 912.5.3 EXCEPTION. | | 3D) 2010 EXISTING BUILDING CODE 912.4.4. HANDRAILS | | SHALL COMPLY WITH 705.9 IN AREAS OF CHANGE OF | | OCCUPANCY. HANDRAILS SHALL BE THE FULL LENGTH OF THE | | RUN OF THE STEPS ON AT LEAST ONE SIDE. | | 3E) 2010 EXISTING BUILDING CODE 912.8 ACCESSIBILITY. | | 3F) 2010 FBC-ACCESSIBILITY CODE 202.4.1 | | DISPROPORTIONATE COST. | | | | 4) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2013-10-10 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-10-10 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-10-10 |
Time |
09:03 |
Sent To |
|
|
Notes |
2013-10-10 09:03:57 | NO ELECTRIC SHOWN, NO REVIEW PERFORMED. DH |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2013-11-02 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-11-02 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-11-02 |
Time |
13:31 |
Sent To |
|
|
Notes |
2013-11-02 13:39:19 | 513 CLEMATIS STREET | | PERMIT #13080797 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | THE UNIT DOORS (A,B, C), STORAGE ROOM DOOR, 1ST LEVEL | | DOOR NEED TO HAVE A FIRE RESISTANCE RATING, LATCH, AND | | AUTOMATIC CLOSER. WINDOWS TO BE FIRE RESISTANCE RATED | | ALSO. SEE BELOW. | | | | NONE OF THE DOORS AND WINDOWS ADJACENT TO THE EXTERIOR | | STAIRS ARE PROTECTED. PER NFPA 101 SECTION 7.2.2.6.3 | | "SEPARATION AND PROTECTION OF OUTSIDE STAIRS: OUTSIDE | | STAIRS SHALL BE SEPARATED FROM THE INTERIOR OF THE | | BUILDING BY CONSTRUCTION WITH THE FIRE RESISTANCE | | RATING REQUIRED FOR ENCLOSED STAIRS WITH FIXED OR | | SELF-CLOSING OPENING PROTECTIVES." WALL CONSTRUCTION | | SHALL EXTEND AS FOLLOWS: (1) VERTICALLY FROM THE | | FINISHED GROUND LEVEL TO A POINT 10 FEET ABOVE THE | | TOPMOST LANDING OF THE STAIRS OR TO THE ROOFLINE, | | WHICHEVER IS LOWER (2) HORIZONTALLY FOR NOT LESS THAN | | 10 FEET. PER NFPA 101 SECTION 7.2.2.6.4 "PROTECTION OF | | OPENINGS: ALL OPENINGS BELOW AN OUTSIDE STAIR SHALL BE | | PROTECTED WITH AN ASSEMBLY HAVING A MINIMUM 45-MINUTE | | FIRE PROTECTION RATING." | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2013-09-19 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-09-19 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-09-19 |
Time |
14:53 |
Sent To |
|
|
Notes |
2013-09-19 16:52:37 | 513 CLEMATIS STREET | | PERMIT #13080797 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | NOTE: THE SECOND FLOOR HAS BOTH AN INSIDE EGRESS STAIR | | AND AN EXTERIOR STAIR; HOWEVER, THE STAIRS ARE NOT | | SEPARATED BY AT LEAST 42 FEET (84 FOOT DIAGONAL/ 2 = 42 | | FEET [WORST CASE] OR 64 FOOT DIAGONAL/ 2 = 32 FEET | | [BEST CASE]) TO BE CONSIDERED TWO SEPARATE EXITS. NEW | | BUSINESS OCCUPANCIES ARE PERMITTED ONE EXIT PER NFPA | | 101 SECTION 38.2.4.3 A SINGLE EXIT SHALL BE PERMITTED | | FOR A ROOM OR AREA WITH A TOTAL OCCUPANT LOAD OF FEWER | | THAN 100 PERSONS WHEN A SINGLE OUTSIDE STAIR IN | | ACCORDANCE WITH 7.2.2 IS INSTALLED AND WILL SERVE ALL | | FLOORS PERMITTED WITHIN THE 15 FEET VERTICAL TRAVEL | | LIMITATION. | | | | NONE OF THE DOORS AND WINDOWS ADJACENT TO THE EXTERIOR | | STAIRS ARE PROTECTED. PER NFPA 101 SECTION 7.2.2.6.3 | | "SEPARATION AND PROTECTION OF OUTSIDE STAIRS: OUTSIDE | | STAIRS SHALL BE SEPARATED FROM THE INTERIOR OF THE | | BUILDING BY CONSTRUCTION WITH THE FIRE RESISTANCE | | RATING REQUIRED FOR ENCLOSED STAIRS WITH FIXED OR | | SELF-CLOSING OPENING PROTECTIVES." WALL CONSTRUCTION | | SHALL EXTEND AS FOLLOWS: (1) VERTICALLY FROM THE | | FINISHED GROUND LEVEL TO A POINT 10 FEET ABOVE THE | | TOPMOST LANDING OF THE STAIRS OR TO THE ROOFLINE, | | WHICHEVER IS LOWER (2) HORIZONTALLY FOR NOT LESS THAN | | 10 FEET. PER NFPA 101 SECTION 7.2.2.6.4 "PROTECTION OF | | OPENINGS: ALL OPENINGS BELOW AN OUTSIDE STAIR SHALL BE | | PROTECTED WITH AN ASSEMBLY HAVING A MINIMUM 45-MINUTE | | FIRE PROTECTION RATING." | | | | PLANS DO NOT INDICATE WHERE THE EXTERIOR STAIR | | DISCHARGES TO. PER NFPA 101 SECTION 7.7.1 EXITS SHALL | | DISCHARGE OR LEAD TO A STREET, ALLEY, PUBLIC WAY, ETC. | | | | PLANS DO NOT INDICATE IF ANY OF THE TENANT SPACES ARE | | FIRE SEPARATED. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2013-08-28 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-08-28 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-09-09 |
Time |
10:52 |
Sent To |
|
|
Notes |
2013-08-28 11:18:05 | 513 CLEMATIS STREET | | PERMIT #13080797 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | THE PERMIT APPLICATION INDICATES A CHANGE OF OCCUPANCY | | FROM RESIDENTIAL TO COMMERCIAL; HOWEVER, THE PLANS DO | | NOT INDICATE THE INTENDED COMMERCIAL OCCUPANCY | | (BUSINESS, MERCANTILE, ETC.) | | | | PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY TYPES, | | OCCUPANT LOADS, FIRE RATED WALLS, FIRE RATE DOORS, EXIT | | SIGNS, EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON | | PATH OF TRAVEL ETC. | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE PERFORMED | | AT THIS TIME. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-10-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-10-10 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-09-12 |
Time |
15:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-11-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-09-12 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-08-21 |
Time |
13:32 |
Sent To |
|
|
Notes |
2013-08-22 13:33:10 | SENT TO B19 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2013-10-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-10-17 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-10-17 |
Time |
14:19 |
Sent To |
FIRE |
|
Notes |
2013-10-17 14:21:30 | IMPACT FEES ASSESSMENT | | CHANGE OF OCCUPANCY UPSTAIRS FROM RESIDENTIAL TO | | BUSINESS. | | TRACKING NUMBER MU-2013-021855-0000 | | AMOUNT $855.82 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2013-09-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-09-24 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-09-24 |
Time |
12:45 |
Sent To |
|
|
Notes |
2013-09-24 12:45:33 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2013-09-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-09-24 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-09-24 |
Time |
12:44 |
Sent To |
|
|
Notes |
2013-09-24 12:44:53 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2013-09-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-09-09 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-09-09 |
Time |
15:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2013-09-09 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-09-09 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-09-09 |
Time |
15:40 |
Sent To |
|
|
Notes |
2013-09-09 15:44:42 | FBC 2010 EXISTING BUILDING CODE | | FBC 2010 ACCESSIBILITY CODE | | FBC 2010 PLUMBING REVIEW #1 | | DENIED: | | | | NO PLUMBING SHOWN AT THIS TIME. HOWEVER, DEPENDING UPON | | THE OCCUPANCY TYPE, THERE MAY BE FIXTURE REQUIREMENTS. | | BUSINESS OCCUPANCIES WITH UNDER 15 OCCUPANTS WOULD NOT | | REQUIRE A DRINKING FOUNTAIN. | | | | REVIEW BY | | LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | PHONE # 805-6692 | | EMAIL [email protected] | | FAX # 805-6676 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2013-09-05 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2013-09-05 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2013-09-05 |
Time |
11:34 |
Sent To |
|
|
Notes |
2013-09-05 11:35:19 | CHANGE OF OCCUPANCY INTO A COMMERCIAL USE. | 2013-08-28 14:49:10 | 8/28/13 |
|
|