Plan Review Details - Permit 13080476
Plan Review Stops For Permit 13080476
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-08-21 Cont ID  
Sent By shill Date 2013-08-21 Time 07:27 Rev Time 0.00
Received By shill Date 2013-08-21 Time 07:27 Sent To  
Notes
2013-08-21 07:31:10****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. FBC 1609, SPECIFICATION FOR FASTENING CANNOT BE "AS
 NEEDED." GRAPHICALLY THREE FASTENERS TOP AND BOTTOM ARE
 SHOWN FOR A 30' SPAN. IF PLANS ARE NOT PREPARED BY A
 DESIGN PROFESSIONAL, PROVIDE CALCULATIONS TO SHOW HOW
 THIS WILL RESIST WIND LOADS.
  
 2. REVISE PLAN TO INCLUDE WIND DESIGN CRITIERA FBC
 1603.4.1.
  
 3. IF PLANS ARE PREPARED BY A DESIGN PROFESSIONAL
 (ARCHITECT OR ENGINEER), TITLE BLOCK REQUIRED FS
 471,481. IF PLANS ARE PREPARED BY SOMEONE OTHER THAN A
 DESIGN PROFESSIONAL, THE PLANS WILL INCLUDE THE PRINTED
 NAME AND SIGNATURE OF THE INDIVIDUAL TAKING
 RESPONSIBILITY FOR THE DESIGN FBC 107.
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2013-08-15 Cont ID  
Sent By dharvey Date 2013-08-15 Time 18:42 Rev Time 0.00
Received By dharvey Date 2013-08-15 Time 18:41 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-08-21 Cont ID  
Sent By shill Date 2013-08-21 Time 07:31 Rev Time 0.00
Received By shill Date 2013-08-13 Time 16:43 Sent To  
Notes
2013-08-13 16:43:20ROUTED TO ZONING

Review Stop Z ZONING
Rev No 1 Status P Date 2013-08-21 Cont ID  
Sent By shill Date 2013-08-21 Time 07:31 Rev Time 0.00
Received By shill Date 2013-08-15 Time 09:32 Sent To  
Notes
2013-08-21 07:32:028/21 OK PER LINDA LOUIE (SEE SIGNATURE ON PLAN AND PLAN
 REVIEW NOTE, NO OUT STOP OR STATUS ENTERED)
  
  
2013-08-15 10:59:58ZONING APPROVED FOR A TEMPORARY SIGN.


Account Summary | Usage Policy | Privacy Policy