Plan Review Details - Permit 13080459
Plan Review Stops For Permit 13080459 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2013-11-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-11-02 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-11-02 |
Time |
14:14 |
Sent To |
|
|
Notes |
2013-11-02 14:15:14 | ****PROVISO**** | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | IMPACT PROTECTION ON SEPARATE PERMIT TO BE ISSUED AND | | FINALED PRIOR TO FINAL INSPECTION. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-10-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-10-19 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-10-19 |
Time |
11:26 |
Sent To |
|
|
Notes |
2013-10-19 11:26:12 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FROM PREVIOUS LISTS: | | | | 1. INSTALLATION SCHEDULE IS INCOMPLETE. SHUTTER | | MOUNTING CONNECTION TYPE, ANCHOR SPACING, SUBSTRATE NOT | | COMPLETED | | | | 2ND REVIEW, THIS INFORMATION NOT PROVIDED. SHUTTER | | MOUNTING CONNECTION TYPE SHOULD CORRELATE WITH THE | | ANCHOR CHARTS (SEE SHEET 11) FOR EXAMPLE, 1 (TOP) OR 5 | | (BOTTOM). | | | | SUBSTRATE SHOULD BE THE SUBSTRATE FOR THE OPENING. THIS | | IS TYPICALLY CONCRETE ON THE TOP, BLOCK ON THE BOTTOM | | DUE TO EDGE DISTANCE REQUIREMENTS. | | | | ANCHOR SPACING - SELF EXPLANATORY. THIS COLUMN IS | | REQUIRED. | | | | 2-3. OK | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-08-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-08-19 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-08-19 |
Time |
16:08 |
Sent To |
|
|
Notes |
2013-08-19 16:08:48 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. INSTALLATION SCHEDULE IS INCOMPLETE. SHUTTER | | MOUNTING CONNECTION TYPE, ANCHOR SPACING, SUBSTRATE NOT | | COMPLETED | | | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | FAC 9N-3. PROVIDE THE FLORIDA STATE COVER SHEET FOR THE | | PANELS. THIS WILL SHOW THE APPROVAL NUMBER AND THE | | STATUS. THIS IS AVAILABLE AT WWW.FLORIDABUILDING.ORG. | | | | 3. SEE THE FOLLOWING DOCUMENT, ITEM #13: | | | | HTTP://WPB.ORG/DEVELOPMENT/CONSTRUCTION/PDF/WIND-BORNE_ | | DEBRIS_IMPLEMETATION.PDF | | | | PROVIDE A PRE-STORM PREPARATION PLAN WHICH INCLUDES ALL | | OF THE REQUIRED INFORMATION. THIS ITEM MAY BE SUBMITTED | | VIA EMAIL. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2013-11-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-11-02 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-10-26 |
Time |
10:46 |
Sent To |
|
|
Notes |
2013-10-26 10:47:06 | TO SH DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-10-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-10-19 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-10-08 |
Time |
09:20 |
Sent To |
|
|
Notes |
2013-10-09 09:21:14 | SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
wlehnhar |
Date |
2013-08-13 |
Time |
15:05 |
Sent To |
|
|
Notes |
2013-08-13 15:06:15 | <5000 BLDG | | |
|
|
|