Plan Review Details - Permit 13070967
Plan Review Stops For Permit 13070967
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-11-20 Cont ID  
Sent By shill Date 2013-11-20 Time 08:25 Rev Time 0.00
Received By shill Date 2013-11-18 Time 12:08 Sent To  
Notes
2013-11-20 09:47:01***PROVISO***
 ***ISSUED AT CONTRACTOR'S RISK***
  
 1. DOOR SHOWN AS "PERMANENTLY SECURE" TO BE REMOVED OR
 RELOCATED; CANNOT BE INOPERABLE PER FBC 1008.1
  
 2. FIRE PARTITION (FBC 709.1) TO BE CONTINUOUS, FBC
 709.4. A HEAD OF WALL ASSEMBLY MAY BE REQUIRED. THIS IS
 TO BE FIELD VERIFIED.
  
 SUBJECT TO FIELD INSPECTOR'S DISCRETION, A REVISION OR
 ADDITIONAL PERMIT MAY BE REQUIRED.
  
 **ALTHOUGH LOCATED IN A SPECIAL HAZARD FLOOD ZONE, IT
 HAS BEEN DETERMINED THAT THIS IMPROVEMENT DOES NOT
 CONSTITUTE A SUBSTANTIAL IMPROVEMENT PER NFIP
 GUIDELINES (SEE WORKSHEET CALCULATIONS IN FILE)**
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-08-05 Cont ID  
Sent By shill Date 2013-08-05 Time 14:59 Rev Time 0.00
Received By shill Date 2013-08-05 Time 14:59 Sent To FIRE
Notes
2013-08-05 15:12:45****CORRECTIONS****
 ****REVISED TO INCLUDE COMMENTS ON ELEVATION
 CERTIFICATE****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. PROVIDE A DETAIL FOR THE FIRE RATED WALL, EITHER A
 TESTED ASSEMBLY OR CALCULATED FIRE RESISTANCE FBC 703.
  
 2. PROVIDE EVIDENCE THAT THE DOUBLE DOOR SHOWN WAS
 PERMITTED TO SERVE TWO SEPARATE UNITS AND WAS CODE
 COMPLIANT AT THE TIME OF INSTALLATION. AS A TENANT
 SEPARATION BETWEEN THE TWO UNITS IS REQUIRED, IT IS NOT
 CLEAR HOW WHY TWO UNITS HAD NO SEPARATION AND A DOOR
 INSTALLED WHICH SERVES THE TWO. THE PROPOSED
 CONSTRUCTION DOES NOT RESOLVE THE ISSUE OF SEPARATING
 THE TWO TENANTS WITH A FIRE RESISTANCE RATED WALL. NON
 COMPLIANT OR NON PERMITTED IMPROVEMENTS DO NOT GET
 GRANDFATHERED.
  
 3. SEE FBC 1014.2.1, THE PLAN PROPOSES THAT UNIT 117
 PASSES THROUGH UNIT 118 IN ORDER TO REACH AN EXIT.
 PLEASE REVISE.
  
 4. THIS STRUCTURE IS LOCATED IN A SPECIAL HAZARD FLOOD
 ZONE. CITY OF WEST PALM BEACH MUNICIPAL CODE 94
 REQUIRES THAT, IN THE CASE OF SUBSTANTIAL IMPROVEMENTS,
 THE STRUCTURE TO BE BROUGHT INTO COMPLIANCE. IF AN
 ELEVATION CERTIFICATE IS AVAILABLE, PLEASE PROVIDE.
 THIS ITEM MAY BE SUBMITTED VIA EMAIL. IF THIS IS NOT
 AVAILABLE, PLEASE ADVISE AND CUMULATIVE LIFETIME
 IMPROVEMENTS ON THIS STRUCTURE WILL BE DETERMINED.
 PLEASE FEEL FREE TO CONTACT ME IF YOU NEED ASSISTANCE.
  
 ***ADDITIONAL COMMENT 9/27**
 ELEVATION CERTIFICATE SENT VIA EMAIL
  
 OUR RECORDS SHOW THIS AS AN A ZONE WITH BFE, SURVEYOR
 STATES THIS IS A C ZONE. PLEASE NOTE THAT THE FLOOD
 ZONE LINE GOES THROUGH THE MIDDLE OF THIS PROPERTY, AND
 ALTHOUGH THE VILLAGES ARE INCLUDED ON A LOMR, THE LOMR
 LETTER FOR VILLAGES ENDS AT THE CANAL BEHIND THIS
 PARCEL. I WAS UNABLE TO LOCATE A LOMR FOR THIS PARCEL.
  
 A COMPLETE REVIEW OF EC WAS NOT DONE AT THIS TIME DUE
 TO UNCERTAINTY OF INFORMATION. HOWEVER, NOTE THE
 FOLLOWING:
  
 LONGITUDE INCORRECT (SHOULD BE NEGATIVE OR WEST)
  
 ELEVATIONS USE NAVD 1988; SEE ELEVATION CERTIFICATE C2,
 STATES THAT ELEVATION DATUM TO BE IN THE SAME FORMAT AS
 BFE. ITEM B11 INDICATES NGVD 1929 WAS USED. CURRENT
 MAPS FOR THE CITY OF WEST PALM BEACH ARE IN NGVD 1929.
  
 COMMENTS LEFT BLANK. THIS SHOULD INCLUDE HOW LAT/LONG
 WERE OBTAINED (SEE INSTRUCTIONS). NOTE THAT SECTION D
 INDICATES THAT COMMENTS ARE PROVIDED.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-11-21 Cont ID  
Sent By skennedy Date 2013-11-21 Time 08:16 Rev Time 0.00
Received By skennedy Date 2013-11-21 Time 08:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-11-21 Cont ID  
Sent By skennedy Date 2013-11-21 Time 09:45 Rev Time 0.00
Received By scaldero Date 2013-11-21 Time 08:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-08-07 Cont ID  
Sent By rferguso Date 2013-08-07 Time 18:04 Rev Time 0.00
Received By rferguso Date 2013-08-07 Time 18:04 Sent To  
Notes
2013-08-07 18:44:401897 PALM BEACH BLVD.
 PERMIT #13070967
  
 WEST PALM BEACH FIRE RESCUE PLAN REVIEW COMMENTS.
  
 * FIRE-RATED WALLS
 PER SECTION 8.3.2.4, EACH FIRE BARRIER SHALL BE
 PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING
 FIRE BARRIER-PROTECT ALL OPENINGS. CHARACTERS SHALL BE
 AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN WIDTH.
 IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 FEET ON
 CENTER.
 PER SECTION 8.3.5.1, PENETRATIONS THROUGH A FIRE-RATED
 WALL ASSEMBLY SHALL BE PROTECTED BY A FIRESTOP SYSTEM
 OR DEVICE.
  
  
  
 RONALD E. FERGUSON, ASSITANT FIRE MARSHAL
 BUREAU OF FIRE PREVENTION
 WEST PALM BEACH FIRE RESCUE
 PHONE #(561) 804-4700
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-11-21 Cont ID  
Sent By skennedy Date 2013-11-21 Time 09:45 Rev Time 0.00
Received By skennedy Date 2013-11-12 Time 18:13 Sent To FIRE
Notes
2013-11-21 08:17:13TO FIRE BOX
2013-11-13 18:13:46B05

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-08-08 Cont ID  
Sent By shill Date 2013-08-08 Time 07:37 Rev Time 0.00
Received By shill Date 2013-07-26 Time 13:11 Sent To  
Notes
2013-07-30 13:11:55SENT TO MISCELLANEOUS #1 SHELF FOR REVIEW. JG.

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-11-21 Cont ID  
Sent By skennedy Date 2013-11-21 Time 08:16 Rev Time 0.00
Received By skennedy Date 2013-11-21 Time 08:16 Sent To  
Notes
***NONE***