Plan Review Details - Permit 13070411
Plan Review Stops For Permit 13070411 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2013-08-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-08-07 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-08-07 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-07-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-07-24 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-07-24 |
Time |
16:04 |
Sent To |
|
|
Notes |
2013-07-24 16:13:21 | RESIDENTIAL (R3) ROOFING, BUILDING REVIEW SECOND | | CHECKLIST | | CODE: 2010 FBC. | | | | 1- FLAT ROOF RAS 117 CALCULATIONS SUBMITTED. | | | | A) ENGINEER TO PROVIDE SKETCH (WITH DIMENSIONS) SHOWING | | HOW ARE THE NINE ROWS OF NAILS IN THE MID-SHEET GOING | | TO BE INSTALLED. NAILS CAN'T NO BE SPACED LESS THAN | | 4"O.C. NINE ROWS DON'T FIT IN THE MID-SHEET. SEE RAS | | 117 SEC. 8.1. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-07-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-07-11 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-07-11 |
Time |
14:19 |
Sent To |
|
|
Notes |
2013-07-11 14:25:11 | RESIDENTIAL (R3) ROOFING, BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC-RESIDENTIAL. | | | | 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR | | NAIL ENHANCING AT ALL ROOF ZONES TO MEET THE CALCULATED | | DESIGN PRESSURES SHOWN ON PLANS SUBMITTED ON THE MASTER | | PERMIT. GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | REQUIRES RAS 117 CALCULATIONS TO BE SIGNED AND SEALED. | | SEC. R301.1. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2013-08-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-08-07 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-08-07 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
F |
Date |
2013-07-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-07-24 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-07-23 |
Time |
17:35 |
Sent To |
|
|
Notes |
2013-07-23 17:35:12 | TO JG DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-07-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-07-11 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-07-11 |
Time |
|
Sent To |
B |
|
Notes |
2013-07-11 13:44:34 | ROUTED TO J GOMEZ ("PROVISO PER J GOMEZ) |
|
|
|