Plan Review Details - Permit 13060770
Plan Review Stops For Permit 13060770
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-03-21 Cont ID  
Sent By shill Date 2014-03-21 Time 19:24 Rev Time 0.00
Received By shill Date 2014-03-21 Time 19:24 Sent To  
Notes
2014-03-21 19:24:54TRUSS DRAWINGS
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-11-04 Cont ID  
Sent By jwitmer Date 2013-11-04 Time 14:28 Rev Time 0.00
Received By jwitmer Date 2013-11-04 Time 14:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-07-22 Cont ID  
Sent By jwitmer Date 2013-07-22 Time 14:18 Rev Time 0.00
Received By jwitmer Date 2013-07-22 Time 13:25 Sent To  
Notes
2013-07-22 14:16:32BUILDING PLAN REVIEW
 PERMIT: 13060770
 ADD: LAMBERTON
 CONT: TBD (TO BE DETERMINED)
 TEL: (561)###-####
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: JULY 22/2013
 ACTION: DENIED
 FITNESS CENTER & MAIL KIOSK
  
 1) MISSING SOILS REPORT. 2010 FBC-B 1803.6.
  
 2) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 3) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) WALL LOUVERS, ,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
  
 4) SHEET A0.06 THIS IS A MIXED USE BLDG, A-3 GYMNASIUM
 4A) REVISE COMMON PATH OF TRAVEL A3 <50 0CCUPANTS 75 FT
 FBC-B 1014.3
 4B) SINGLE EXIT FOR A3 <50 OCCUPANTS FBC-B T1021.2
 4C) OCCUPANCY MIXED USE A3/B
 4D) A0.06 NOR A1.61 PLANS INDICATE OCCUPANT LOAD OF 31
 USING 50 SQ FT WITH EQUIPMENT, EQUIPMENT NOT SHOWN.
 GYMS WITHOUT EQUIPMENT SHOWN 1/ 15
 WHICH WILL INCREASE THE OCCUPANT LOAD TO 104 REQUIRING
 2 DOORS.
  
 5) A0.10 BUILDINGS ON THE SAME LOT, PLEASE PROVIDE AN
 ASSUMDED PROPERTY LINE BETWEEN TTHE FITNESS CENTER AND
 BUILDINGS 3 & 13, PROVIDE THE DISTANCE TO THE ASSUMED
 PROPERTY LINE FOR COMPLIANCE WITH 2010 FBC-B TABLE 602
 & TABLE 705.8.
  
 6) MISSING ON PLANS 2010 FBC-B 1209.2 ATTIC SPACES.
 AN OPENING NOT LESS THAN 20 INCHES BY 30 INCHES (559 MM
 BY 762 MM) SHALL BE PROVIDED TO ANY ATTIC AREA HAVING A
 CLEAR HEIGHT OF OVER 30 INCHES (762 MM). A 30-INCH (762
 MM) MINIMUM CLEAR HEADROOM IN THE ATTIC SPACE SHALL BE
 PROVIDED AT OR ABOVE THE ACCESS OPENING.
  
 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-11-14 Cont ID  
Sent By albarran Date 2013-11-14 Time 18:40 Rev Time 0.00
Received By albarran Date 2013-11-14 Time 17:14 Sent To  
Notes
2013-11-14 18:42:05I APPROVED THE PERMIT, AND MADE A NOTATION AS TO THE
 DRINKING FOUNTAIN REQUIREMENT OF NEC 422.52

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-09-12 Cont ID  
Sent By dharvey Date 2013-09-12 Time 12:04 Rev Time 0.00
Received By dharvey Date 2013-09-12 Time 11:26 Sent To  
Notes
2013-09-12 12:04:5913060770
 300 COURTNEY LAKES CIRCLE
 FITNESS CENTER
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS.
  
 PROVIDE MOUNTING DETAIL FOR TELEVISIONS AND CEILING
 FANS. NEC 110.13
 VENDING MACHINES REQUIRE GROUND FAULT PROTECTION. NEC
 422.51
 OUTDOOR ELECTRICAL ENCLOSURES REQUIRE PROTECTION
 AGAINST RAIN. NEC 110.20
  
 ROBERT LECKY
 ELECTRICAL PLANS REVIEW
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-07-05 Cont ID  
Sent By scaldero Date 2013-07-05 Time 08:34 Rev Time 0.00
Received By scaldero Date 2013-07-02 Time 08:34 Sent To  
Notes
2013-07-05 08:40:14PROVIDE A FITNESS SCHEDULE TO SUPPORT THE USE OF 50 SF
 PER PERSON, AS OPPOSED TO 15 SF. (SHEET A006)

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date 2013-11-15 Cont ID  
Sent By rregueir Date 2013-11-14 Time 12:36 Rev Time 0.00
Received By rregueir Date 2013-09-19 Time 12:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2013-09-12 Time   Rev Time 0.00
Received By rregueir Date 2013-06-24 Time 15:44 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2013-11-04 Cont ID  
Sent By jwitmer Date 2013-10-27 Time 09:08 Rev Time 0.00
Received By jwitmer Date 2013-10-27 Time 09:08 Sent To  
Notes
2013-10-27 09:09:4910/28/2013PB COUNTY IMPACT FEE ASSESSMENT
 MU 2013-22517
 $900.36

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-07-22 Cont ID  
Sent By jwitmer Date 2013-07-22 Time 14:18 Rev Time 0.00
Received By jwitmer Date 2013-07-22 Time 14:18 Sent To  
Notes
2013-07-22 14:18:56BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-08-14 Cont ID  
Sent By rregueir Date 2013-08-14 Time 10:47 Rev Time 0.00
Received By rregueir Date 2013-08-14 Time 10:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-11-13 Cont ID  
Sent By lwagner Date 2013-11-13 Time 14:18 Rev Time 0.00
Received By lwagner Date 2013-11-13 Time 14:17 Sent To  
Notes
2013-11-13 14:18:26PER REVISION TO A0.06 THE OCCUPANCY IS BUSINESS. NO MOP
 SINK WILL BE REQUIRED.

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-07-08 Cont ID  
Sent By lwagner Date 2013-07-08 Time 10:15 Rev Time 0.00
Received By lwagner Date 2013-07-03 Time 12:57 Sent To  
Notes
2013-07-08 09:51:06FBC 2010 ACCESSIBILITY CODE
 FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
 1. SHEET A0006 THE PLUMBING TABLE LISTS THE OCCUPANCY
 AS TYPE A-3 . TABLE 403.1 REQUIRES A SERVICE SINK FOR
 A-3 OCCUPANCIES.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2014-01-17 Cont ID  
Sent By rregueir Date 2014-01-17 Time 16:30 Rev Time 0.00
Received By rregueir Date 2014-01-17 Time 16:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2013-10-10 Cont ID  
Sent By ajones Date 2013-10-10 Time 11:24 Rev Time 0.00
Received By ajones Date 2013-10-10 Time 11:24 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2013-07-22 Cont ID  
Sent By avann Date 2013-07-22 Time 16:15 Rev Time 0.00
Received By ajones Date 2013-07-22 Time 16:15 Sent To  
Notes
2013-07-22 16:23:247/22/13- FAILED. THE ORIGINAL APPROVAL SHOWED THE MAIL
 KIOSK AND THE FITNESS CENTER AS TWO (2) SEPARATE
 BUILDINGS. THE BUILDING PERMIT SHOWS THEM AS A COMBINED
 BUILDING AND DRASTIC CHANGES IN THE ELEVATIONS. A MINOR
 AMENDMENT TO THE RESIDENTIAL PLANNED DEVELOPMENT IS
 REQUIRED BECAUSE OF THE SUBSTANTIAL CHANGE IN THESE TWO
 (2) BUILDINGS.
  
 ANGELLA VANN, PLANNING AND ZONING ADMINISTRATOR
 561-822-1441