Plan Review Details - Permit 13051060
Plan Review Stops For Permit 13051060
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-07-19 Cont ID  
Sent By jwitmer Date 2013-07-19 Time 10:06 Rev Time 0.00
Received By jwitmer Date 2013-07-19 Time 10:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-06-15 Cont ID  
Sent By jwitmer Date 2013-06-15 Time 16:04 Rev Time 0.00
Received By jwitmer Date 2013-06-14 Time 15:00 Sent To  
Notes
2013-06-14 16:14:53BUILDING PLAN REVIEW
 PERMIT: 13051060
 ADD: 2101 CENTREPARK BLVD # 110
 CONT: CHANDLER CONSTRUCTION
 TEL: (561)791-6934
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: 6/14/2013
 ACTION: DENIED
  
 1) THE PROJECT DATA DOES NOT INDICATE THE BUILDING IS
 FIRE SPRINKLERED, SHEET A-3.0 THE FIRE SPRINKLER HEAD
 PLAN IS LOCATED. HAVING THE FIRE SPRINKLER DESIGNATION
 IN THE PROJECT DATA SETS UP THE PERIMETERS THE PLAN
 REVIEW WILL OCCUR UNDER.
  
 2) SHEET A-1 INDICATES WITHIN THE BUSINESS OCCUPANCY
 THERE IS LOCATED TWO CONFERENCE ROOMS THE TOTAL SQ FEET
 OF THESE COMBINED AREA IS 1154 SQ FT. TO CONSIDER THIS
 AREA AS A ACCESSORY OCCUPANCY THROUGH THE FBC-B
 508.2.1, AGGREGATE ACCESSORY OCCUPANCIES SHALL NOT
 OCCUPY MORE THAN 10 PERCENT OF THE BUILDING AREA OF THE
 STORY IN WHICH THEY ARE LOCATED AND SHALL NOT EXCEED
 THE TABULAR VALUES IN TABLE 503, WITHOUT BUILDING AREA
 INCREASES IN ACCORDANCE WITH SECTION 506 FOR SUCH
 ACCESSORY OCCUPANCIES.
  
 THE TOTAL FLOOR AREA, FOOT PRINT OF THIS BUILDING IS
 25,272 SQ FT THE DESIGNER OF RECORD CAN PROVIDE
 DOCUMENTATION THAT THE TOTAL SQ FOOTAGE OF COMBINED
 TENANTS CONFERENCE ROOMS DOES NOT EXCEED THE 10% OF THE
 BUILDING AREA THEN THIS CAN BE CONSIDERED A ACCESSORY
 OCCUPANCY.
  
 3) SHEET A-3 DOES INDICATE THIS BUILDING IS A
 SPRINKLERED BUILDING, ONE OF THE EXCEPTIONS TO MANUAL
 FIRE ALARM BOXES IN FIRE SPRINKLERED BUILDINGS IS FOUND
 IN 2010 FBC-B 907.2.2 FOR GROUP B OCCUPANCIES, BUT
 PLEASE NOTE FBC-B 907.2. WHERE OTHER SECTIONS OF THIS
 CODE ALLOW ELIMINATION OF FIRE ALARM BOXES DUE TO
 SPRINKLERS, A SINGLE FIRE ALARM BOX SHALL BE INSTALLED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-08-02 Cont ID  
Sent By dharvey Date 2013-08-02 Time 14:24 Rev Time 0.00
Received By dharvey Date 2013-08-02 Time 13:36 Sent To  
Notes
2013-07-17 14:41:34NEW SHEETS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-06-28 Cont ID  
Sent By dharvey Date 2013-06-28 Time 09:09 Rev Time 0.00
Received By dharvey Date 2013-06-27 Time 15:11 Sent To  
Notes
2013-06-28 09:09:54BY RL

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-07-26 Cont ID  
Sent By wjolin Date 2013-07-26 Time 12:43 Rev Time 0.00
Received By wjolin Date 2013-07-26 Time 11:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-06-08 Cont ID  
Sent By wjolin Date 2013-06-08 Time 11:15 Rev Time 0.00
Received By wjolin Date 2013-06-08 Time 11:04 Sent To  
Notes
2013-06-08 11:15:212101 CENTERPARK DRIVE - WEST: SUITE #110
 PERMIT #13051060
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE PLANS INDICATE A BUSINESS OCCUPANCY; HOWEVER, THE
 COMBINED SIZE OF THE TWO ASSEMBLY USE CONFERENCE ROOMS
 IS APPROXIMATELY 1,155 SQ.FT. OR 17% OF SUITE #110
 (6,620 SQ.FT.). FOR THE ASSEMBLY SPACES TO BE
 CONSIDERED ACCESSORY TO THE BUSINESS OCCUPANCY, THE
 ASSEMBLY SPACES CANNOT EXCEED 10% OF THE SUITE AREA.
  
 THE BUILDING IS FUNCTIONING AS A MULTIUSE OCCUPANCY.
 INDICATE IF THE BUILDING IS DESIGNED FOR MIXED USE
 (NON-SEPARATED) OR SEPARATED USE PER SECTION 6.1.14.2.1
 OF NFPA 101 FLORIDA EDITION 2009. FOR NON-SEPARATED
 MIXED USE OCCUPANCIES, THE MOST STRINGENT FIRE AND LIFE
 SAFETY REQUIREMENTS OF EACH OCCUPANCY SHALL APPLY TO
 THE BUILDING.
  
 PROVIDE AN OCCUPANT LOAD BREAKDOWN FOR THE SUITE.
  
 EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS
 SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A
 CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM.
 SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF
 OCCUPANTS PERMITTED FOR EACH ROOM.
  
 ELECTRICAL: EMERGENCY ILLUMINATION SHALL BE PROVIDED
 FOR A MINIMUM OF 1.5 HOURS IN THE EVENT OF FAILURE OF
 NORMAL LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE
 ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT
 LESS THAN AN AVERAGE OF 1 FT-CANDLE AND, AT ANY POINT,
 NOT LESS THAN 0.1 FT-CANDLE, MEASURED ALONG THE PATH OF
 EGRESS AT FLOOR LEVEL.
  
 ELECTRICAL: NO ENGINEERED FIRE ALARM DRAWINGS
 SUBMITTED. PER FBC SECTION 907.1.1 CONSTRUCTION
 DOCUMENTS - "CONSTRUCTION DOCUMENTS FOR FIRE ALARM
 SYSTEMS SHALL BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND
 SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS
 OF THIS CODE, THE FLORIDA FIRE PREVENTION CODE, AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL."
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-08-02 Cont ID  
Sent By dharvey Date 2013-08-02 Time 14:24 Rev Time 0.00
Received By dharvey Date 2013-07-16 Time 14:46 Sent To  
Notes
2013-07-17 14:46:42SENT TO B2 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-07-03 Cont ID  
Sent By hmoser Date 2013-07-03 Time 08:37 Rev Time 0.00
Received By hmoser Date 2013-05-30 Time 11:10 Sent To  
Notes
2013-05-31 11:11:00SENT TO B11 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-07-19 Cont ID  
Sent By jwitmer Date 2013-07-19 Time 10:06 Rev Time 0.00
Received By jwitmer Date 2013-07-19 Time 10:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-07-03 Cont ID  
Sent By hmoser Date 2013-07-03 Time 08:24 Rev Time 0.00
Received By hmoser Date 2013-07-03 Time 07:58 Sent To  
Notes
2013-07-03 08:24:10PLANS DENIED
 PROVIDE RETURN AIR DUCT SIZE IN ROOMS 113,114
 AND ALL TAPS IN RETURN AIR GRILLS.
 PER SECTION 107 2010 FBC
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 1 Status N Date 2013-06-04 Cont ID  
Sent By lwagner Date 2013-06-04 Time 12:49 Rev Time 0.00
Received By lwagner Date 2013-06-04 Time 12:41 Sent To  
Notes
2013-06-04 12:49:37NO PLUMBING SHOWN AT THIS TIME.

Review Stop Z ZONING
Rev No 1 Status N Date 2013-06-03 Cont ID  
Sent By ajones Date 2013-06-03 Time 14:50 Rev Time 0.00
Received By ajones Date 2013-06-03 Time 14:50 Sent To  
Notes
2013-06-03 14:50:386/3/13- NOT REQUIRED FOR OFFICE ONLY