Plan Review Details - Permit 13050986
Plan Review Stops For Permit 13050986
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-07-24 Cont ID  
Sent By jwitmer Date 2013-07-24 Time 07:30 Rev Time 0.00
Received By jwitmer Date 2013-07-24 Time 07:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-06-13 Cont ID  
Sent By jwitmer Date 2013-06-13 Time 14:28 Rev Time 0.00
Received By jwitmer Date 2013-06-13 Time 14:27 Sent To  
Notes
2013-06-13 15:25:15BUILDING PLAN REVIEW
 PERMIT: 13050986
 ADD: 550 OKEECHOBEE BLVD # 1701
 CONT: D'ANGELO BUILDERS INC
 TEL: (561)582-2028
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: 6/13/13
 ACTION: DENIED
  
 1) SHEET D1.0 PROJECT DATA
 1A) CONSTTRUCTION TYPE IS LISTED AS IB TABLE 503 WOULD
 ONLY ALLOW A 11 STORY BUILDING AND 1 EXTRA STORY FOR
 FIRE SPRINKLERS. THIS IS A TYPE IA CONSTRUCTION. 2010
 FBC-B TABLE 503.
 1B) OCCUPANCY CLASSIFICATION IS NOT R-3 THIS IS SINGLE
 FAMILY UN-ATTACHED, SEE 2010 FBC-B 310 R-2.
  
 2) SHEET A-1.0 NOTE "H" INDICATES THE USE OF TRAVERTINE
 FLOORING, PROVIDE CODE COMPLIANCE FOR ECB PRODUCTS:
 2A) FBC-B 2010 603.2 EXCEPTION (1)
 FLOOR INSULATION PLACED BETWEEN TWO LAYERS OF
 NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING
 AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX
 OF NOT MORE THAN 100.
  
 2B) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 3) SHEET A-1.0 NOTE E INDICATES THE USE OF MR BOARD IN
 WET AREAS,
 2010 FBC-B 2509.2 BASE FOR TILE.
 GLASS MAT WATER-RESISTANT GYPSUM BACKING PANELS,
 DISCRETE NONASBESTOS FIBER-CEMENT INTERIOR SUBSTRATE
 SHEETS OR NONASBESTOS FIBER-MAT REINFORCED CEMENT
 SUBSTRATE SHEETS IN COMPLIANCE WITH ASTM C 1178, C 1288
 OR C 1325 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER
 RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE
 IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN
 SHOWER AREAS. WATER-RESISTANT GYPSUM BACKING BOARD
 SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET
 COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH
 GA-216 OR ASTM C 840 AND MANUFACTURER RECOMMENDATIONS.
 REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR
 WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840.
  
 2509.3 LIMITATIONS.
 WATER-RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED
 IN THE FOLLOWING LOCATIONS:
  
 1. OVER A VAPOR RETARDER IN SHOWER OR BATHTUB
 COMPARTMENTS.
  
 2. WHERE THERE WILL BE DIRECT EXPOSURE TO WATER OR IN
 AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY.
  
 3. ON CEILINGS WHERE FRAME SPACING EXCEEDS 12 INCHES
 (305 MM) O.C. FOR 1/2-INCH-THICK (12.7 MM)
 WATER-RESISTANT GYPSUM BACKING BOARD AND MORE THAN 16
 INCHES (406 MM) O.C. FOR 5/8-INCH-THICK (15.9 MM)
 WATER-RESISTANT GYPSUM BACKING BOARD.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-07-01 Cont ID  
Sent By dharvey Date 2013-07-01 Time 09:13 Rev Time 0.00
Received By dharvey Date 2013-06-28 Time 14:49 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-06-14 Cont ID  
Sent By wjolin Date 2013-06-14 Time 12:30 Rev Time 0.00
Received By wjolin Date 2013-06-14 Time 11:35 Sent To  
Notes
2013-06-14 11:42:58550 SOUTH OKEECHOBEE BOULEVARD - SUITE #1701
 PERMIT #13050986
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK INFORMATION.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-07-24 Cont ID  
Sent By jwitmer Date 2013-07-24 Time 07:30 Rev Time 0.00
Received By jwitmer Date 2013-07-11 Time 12:46 Sent To  
Notes
2013-07-12 12:45:33C02
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-07-02 Cont ID  
Sent By hmoser Date 2013-07-02 Time 15:14 Rev Time 0.00
Received By hmoser Date 2013-05-29 Time 08:08 Sent To  
Notes
2013-05-30 08:08:33INCOMING SENT TO C02 BOX. JW

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-07-24 Cont ID  
Sent By jwitmer Date 2013-07-24 Time 07:26 Rev Time 0.00
Received By jwitmer Date 2013-07-24 Time 07:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-07-02 Cont ID  
Sent By hmoser Date 2013-07-02 Time 15:14 Rev Time 0.00
Received By hmoser Date 2013-07-02 Time 15:03 Sent To  
Notes
2013-07-02 15:14:30PLANS DENIED
 REFER TO SECTION 601.4 BALANCED RETURN AIR.
 2010 FBC (M)
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-06-04 Cont ID  
Sent By lwagner Date 2013-06-04 Time 14:27 Rev Time 0.00
Received By lwagner Date 2013-06-04 Time 14:05 Sent To  
Notes
***NONE***