|
 |
 |
 |
 |
 |
Plan Review Details - Permit 13050808
Plan Review Stops For Permit 13050808 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2013-05-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-05-24 |
Time |
07:05 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-05-24 |
Time |
06:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2013-05-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-05-31 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-05-31 |
Time |
13:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-05-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-05-24 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-05-24 |
Time |
07:53 |
Sent To |
Z |
|
Notes |
2013-05-24 08:44:02 | 2010 FBC AND 2008 NEC | | | | DENIED BY ELECTRIC | | | | 1) THE ELECTRICAL DIAGRAM ON SHEET 2 SPECIFIES A GAS | | HEATER AND SHEET 1, THE CUT SHEETS AND LOAD | | CALCULATIONS ARE FOR AN ELECTRIC HEAT PUMP. PLEASE | | REVISE SHEET 2 TO SHOW THE CORRECT PANEL AND WIRE SIZES | | FOR THE 6.9 KW HEAT PUMP. CITY AMENDMENTS 107.2.1 NEC | | 215, 220, 240.4 & 310.15 | | | | 2) AT LEAST ONE 15 OR 20 AMP GFCI RECEPTACLE LOCATED | | BETWEEN 6 AND 20 FEET OF THE POOL IS REQUIRED BY NEC | | 680.22(A)(3). | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2013-05-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-05-24 |
Time |
07:06 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-05-24 |
Time |
07:06 |
Sent To |
|
|
Notes |
2013-05-24 07:07:09 | ELECTRIC HEAT PUMP IS SPECIFIED. NO GAS SHOWN ON PLANS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-05-29 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2013-05-29 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2013-05-24 |
Time |
08:44 |
Sent To |
|
|
Notes |
2013-05-24 08:44:54 | SENT TO ZONING BOX. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2013-05-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-05-24 |
Time |
07:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-05-24 |
Time |
07:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2013-05-29 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2013-05-29 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2013-05-29 |
Time |
12:03 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |