Plan Review Details - Permit 13050751
Plan Review Stops For Permit 13050751 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2013-05-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-05-29 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-05-29 |
Time |
11:57 |
Sent To |
|
|
Notes |
2013-05-29 12:14:16 | BUILDING PLAN REVIEW | | PERMIT: 13050751 | | ADD: 1701 S FLAGLER DR SUITE # 102 | | CONT: TROPICAL CONCRETE RESTORATION | | TEL: (561)644-1810 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: 5/29/2013 | | ACTION: PROVISO | | 804.1 GENERAL. | | INTERIOR FLOOR FINISH AND FLOOR COVERING MATERIALS | | SHALL COMPLY WITH SECTIONS 804.2 THROUGH 804.4.1. | | | | EXCEPTION: FLOOR FINISHES AND COVERINGS OF A | | TRADITIONAL TYPE, SUCH AS WOOD, VINYL, LINOLEUM OR | | TERRAZZO, AND RESILIENT FLOOR COVERING MATERIALS THAT | | ARE NOT COMPRISED OF FIBERS. | | | | | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2013-05-31 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-05-31 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-05-31 |
Time |
08:35 |
Sent To |
|
|
Notes |
2013-05-31 08:42:06 | 5-31-13 - PROVISO | | APPROVED WITH EXCEPTION. SEE NOTE ON DRAWING | | VB |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2013-06-04 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-06-04 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-06-04 |
Time |
14:49 |
Sent To |
M |
|
Notes |
2013-06-04 14:50:49 | 1701 SOUTH FLAGLER DRIVE - SUITE #102 | | PERMIT #13050751 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | EXISTING APARTMENT BUILDINGS NOT PROTECTED BY AUTOMATIC | | SPRINKLERS OR A COMPLETE AUTOMATIC SMOKE DETECTION | | SYSTEM SHALL HAVE SINGLE STATION OR MULTI-STATION SMOKE | | ALARMS (HARD-WIRED OR BATTERY POWERED) INSTALLED INSIDE | | EACH BEDROOM AND DIRECTLY OUTSIDE BEDROOM DOORS. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-06-05 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-06-05 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-05-22 |
Time |
16:57 |
Sent To |
|
|
Notes |
2013-05-22 16:58:01 | INCOMING SENT TO B-18. JW |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2013-06-05 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-06-05 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-06-05 |
Time |
08:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2013-05-28 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-05-28 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-05-28 |
Time |
15:42 |
Sent To |
|
|
Notes |
|
|
|