Plan Review Stops For Permit 13050618 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2013-07-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-07-03 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-07-03 |
Time |
09:07 |
Sent To |
|
|
Notes |
2013-07-03 09:09:19 | PROVISO | | | | SEPARATE PERMIT FOR SHUTTERS | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-07-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-07-02 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-07-02 |
Time |
16:33 |
Sent To |
|
|
Notes |
2013-07-02 16:33:38 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | FROM PREVIOUS LIST: | | | | 1. OK | | | | 2. IMPACT PROTECTION REQUIRED FOR NEW SLIDERS, FBC R | | 301.2.1.2. | | | | PROVIDE EITHER IMPACT SLIDING GLASS DOOR PRODUCT | | APPROVALS, OR IMPACT PROTECTION PRODUCT APPROVALS. IF | | SHUTTERS ARE PROPOSED, COMPLETE THE SAMPLE INSTALLATION | | SCHEDULE OR PROVIDE ALL INFORMATION TO SHOW CODE | | COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC R301, | | FBC1609. TWO SETS REQUIRED. THIS FORM IS AVAILABLE IN | | THE LOBBY OR ON THE INTERNET AT | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | 3. OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-06-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-06-18 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-06-18 |
Time |
10:11 |
Sent To |
|
|
Notes |
2013-06-18 10:23:59 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. SCOPE NOT CLEAR. | | | | WINDOW PRODUCT APPROVAL SUBMITTED, NO WINDOW | | REPLACEMENT SHOWN ON PLAN. | | | | PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, SIZES, | | WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING | | CANNOT BE REDUCED BY MORE THAN 5%. | | | | 2. IMPACT PROTECTION REQUIRED FOR NEW SLIDERS, FBC R | | 301.2.1.2. | | | | PROVIDE EITHER IMPACT SLIDING GLASS DOOR PRODUCT | | APPROVALS, OR IMPACT PROTECTION PRODUCT APPROVALS. IF | | SHUTTERS ARE PROPOSED, COMPLETE THE SAMPLE INSTALLATION | | SCHEDULE OR PROVIDE ALL INFORMATION TO SHOW CODE | | COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC R301, | | FBC1609. TWO SETS REQUIRED. THIS FORM IS AVAILABLE IN | | THE LOBBY OR ON THE INTERNET AT | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | | | 3. EXPEDITED REQUEST HAS BEEN VOIDED AS WE WERE UNABLE | | TO ACCOMODATE THAT REQUEST (AND NO FEES CHARGED). IF | | YOU WISH FOR THE SECOND REVIEW TO BE EXPEDITED, PLEASE | | COMPLETE ANOTHER EXPEDITED REQUEST FORM. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2013-07-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-07-02 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-07-02 |
Time |
08:45 |
Sent To |
|
|
Notes |
2013-07-02 08:45:36 | SENT TO S HILL |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-06-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-06-14 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-06-14 |
Time |
15:46 |
Sent To |
|
|
Notes |
2013-06-14 15:54:32 | 2010 FBC / 2008 NEC | | | | DENIED BY ELECTRICAL | | | | 1) SUBMIT TWO SETS OF ELECTRICAL PLANS SHOWING THE | | LOCATIONS OF EXISTING AND RELOCATED OUTLETS AND THAT | | ALL WORK COMPLIES WITH THE 2008 NATIONAL ELECTRICAL | | CODE. CITY AMENDMENTS 107.2.1 | | | | 2) MULTIWIRE BRANCH CIRCUITS ARE REQUIRED TO COMPLY | | WITH NEC 210.4. | | | | 3) ARC-FAULT PROTECTION IS REQUIRED TO COMPLY WITH NEC | | 210.4. | | | | 4) TAMPER RESISTANT RECEPTACLES ARE REQUIRED TO COMPLY | | WITH NEC 406.11. | | | | 5) SHOW COMPLIANCE WITH FBCR 314.3.1 FOR REQUIRED SMOKE | | DETECTORS. | | | | 6) THE NAME, SIGNATURE AND LICENSE NUMBER OF THE PERSON | | RESPONSIBLE FOR THE DESIGN IS REQUIRED ON THE PLANS. | | CITY AMENDMENTS 107.2.1 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2013-06-05 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-06-05 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-06-05 |
Time |
14:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-07-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-07-02 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-06-21 |
Time |
10:45 |
Sent To |
|
|
Notes |
2013-06-21 10:46:13 | ONLY ADDRESSING ELECTRICAL COMMENTS. SUBMITTAL SENT TO | | MCDOUGAL'S DESK FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-06-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-06-18 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-05-17 |
Time |
17:01 |
Sent To |
|
|
Notes |
2013-06-12 11:10:34 | 6/12 TO RM DESK FOR ELEC/PLUMBING REVIEWS | 2013-06-06 09:28:33 | 6/6/13 IN MISC. #1 | 2013-05-17 17:01:58 | EXPEDITED | | ROUTED TO ZONING BOX FOR HISTORIC REVIEW |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2013-06-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-06-14 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-06-14 |
Time |
15:26 |
Sent To |
|
|
Notes |
2013-06-14 15:28:07 | REMOVE AND REPLACE EXISTING FIXTURES IN SAME LOCATIONS. | | A PLUMBING SUB-PERMIT IS REQUIRED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2013-06-05 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-06-05 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-06-05 |
Time |
14:04 |
Sent To |
|
|
Notes |
|
|