Plan Review Details - Permit 13050215
Plan Review Stops For Permit 13050215
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-06-20 Cont ID  
Sent By rmcdouga Date 2013-06-20 Time 16:48 Rev Time 0.00
Received By rmcdouga Date 2013-06-20 Time 15:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-05-31 Cont ID  
Sent By rmcdouga Date 2013-05-31 Time 16:32 Rev Time 0.00
Received By rmcdouga Date 2013-05-31 Time 16:32 Sent To  
Notes
2013-05-31 15:26:562010 FBC
  
 DENIED BY BUILDING
  
 1) SUBMIT PRODUCT APPROVALS FOR THE ROOFING MATERIAL
 AND THE SIMPSON CONNECTORS AND ANCHORS SPECIFIED ON THE
 PLANS. DCA RULE 9N-3
  
 2) SPECIFY THE ROOF SHEATHING MATERIAL AND THE
 FASTENERS AND SPACING. FBC R803
  
 3) THE NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR
 THE DESIGN IS REQUIRED ON THE PLANS. CITY AMENDMENTS
 107.2.1
  
 4) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR
 THE PROJECT. CITY AMENDMENTS 107.3.4.1
  
 5) THE ROOF UPLIFT CALCULATIONS AND BASE SHEET FASTENER
 SPACING INFORMATION ON THE PLANS ARE ILLEGIBLE. PLEASE
 CORRECT.
  
 6) THE PLANS SPECIFY GWB (GYPSUM WALL BOARD) ON THE
 CEILING OF THE OPEN PORCH. GWB IS NOT AN ACCEPTED
 EXTERIOR COVERING. SEE FBC R703.1 SUBMIT TWO COPIES OF
 THE PRODUCT APPROVALS FOR THE GWB THAT IS SPECIFIED AS
 THE CLADDING FOR THE EXTERIOR PORCH CEILING AS REQUIRED
 BY DCA RULE 9N-3.
  
 7) SHOW COMPLIANCE WITH FBC R314.3.1 FOR REQUIRED SMOKE
 ALARMS.
  
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-05-31 Cont ID  
Sent By dharvey Date 2013-05-17 Time 15:04 Rev Time 0.00
Received By dharvey Date 2013-05-17 Time 15:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-06-24 Cont ID  
Sent By rmcdouga Date 2013-06-24 Time 13:22 Rev Time 0.00
Received By rmcdouga Date 2013-06-05 Time 12:15 Sent To  
Notes
2013-06-05 12:16:13INCOMING SENT TO R MCDOUGALS' DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-05-31 Cont ID  
Sent By rmcdouga Date 2013-05-31 Time 16:32 Rev Time 0.00
Received By rmcdouga Date 2013-05-07 Time 15:36 Sent To  
Notes
2013-05-07 15:37:15SENT TO R13 SHELF FOR REVIEW. JG.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2013-06-24 Cont ID  
Sent By rmcdouga Date 2013-06-24 Time 13:22 Rev Time 0.00
Received By rmcdouga Date 2013-06-20 Time 16:48 Sent To  
Notes
2013-06-20 16:50:32THE APPROVED ASSEMBLY WITH A MAXIMUM DESIGN PRESSURE OF
 -52.5 PSF ON PAGE 29 FROM GAF MODIFIED BITUMEN ROOF
 SYSTEM NOA # 09-0224.01 WILL BE USED. SIGNED AND SEALED
 RAS 117 CALCULATIONS FOR ENHANCED FASTENING PER
 LIMITATION #7 OF THE NOA ARE REQUIRED TO BE SUBMITTED
 AS A REVISION AND APPROVED PRIOR TO INSTALLATION.

Review Stop Z ZONING
Rev No 1 Status P Date 2013-05-14 Cont ID  
Sent By jroach Date 2013-05-14 Time 10:52 Rev Time 0.00
Received By jroach Date 2013-05-14 Time 10:37 Sent To B
Notes
2013-05-10 10:41:295/10/13