Plan Review Stops For Permit 13050212 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2013-09-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-09-23 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-09-23 |
Time |
16:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2013-08-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-08-05 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-08-05 |
Time |
14:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-05-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-05-28 |
Time |
19:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-05-28 |
Time |
19:08 |
Sent To |
|
|
Notes |
2013-05-28 19:09:04 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR | | THE ROOF PANELS, FAC 9N-3. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2013-09-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-09-23 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-09-09 |
Time |
14:12 |
Sent To |
|
|
Notes |
2013-09-09 14:13:14 | SENT TO ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-08-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-08-05 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-07-15 |
Time |
15:47 |
Sent To |
|
|
Notes |
2013-07-15 15:52:26 | INCOMING SENT TO ZONING BOX. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-05-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-05-28 |
Time |
19:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-05-07 |
Time |
11:48 |
Sent To |
|
|
Notes |
2013-05-08 11:48:47 | SENT TO ZONING SHELF FOR REVIEW. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2013-09-19 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2013-09-19 |
Time |
15:09 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2013-09-19 |
Time |
15:09 |
Sent To |
B |
|
Notes |
2013-09-10 13:49:02 | ZONING RECEIVED. ROUTED TO ES FOR REVIEW. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2013-07-29 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2013-07-29 |
Time |
15:10 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2013-07-29 |
Time |
15:10 |
Sent To |
B |
|
Notes |
2013-07-29 15:25:24 | FAILED | | | | 1) NEW STRUCTURAL DETAILS WERE NOT SUBMITTED TO SHOW | | THE ROOF STRUCTURAL SUPPORT MEETING THE REQUIRED REAR | | SETBACK OF 10 FEET. THE ORIGINALLY SUBMITTED | | ENGINEERING SHOWS THE SUPPORTS VIOLATING THE SET BACK | | AND MAY NOT BE USED FOR THE CHANGED CONFIGURATION. | | | | 2) THE LEFT AND RIGHT ELEVATIONS SHOW LUMITE SCREEN AND | | REGULAR SCREEN EXTENDING PAST THE 10 FOOT REAR SETBACK | | LINE. WHILE THE ROOF IS PERMITTED TO OVERHANG INTO THE | | SETBACK, THERE IS NO CONSTRUCTION ALLOWED UNDER IT. | | THIS WOULD NO LONGER BE AN OVERHANG, BUT RATHER AN | | EXTENSION OF THE PRIMARY STRUCTURE. | | | | 3) THE ROOF OVERHANG IS 42 INCHES (2' 6" PLUS 12") NOT | | 36 INCHES AS PERMITTED BY THE OAKTON COMMONS DESIGN | | GUIDELINES. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2013-05-24 |
|
|
Cont ID |
|
Sent By |
eschenid |
Date |
2013-05-24 |
Time |
13:56 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2013-05-16 |
Time |
14:21 |
Sent To |
B |
|
Notes |
2013-05-24 14:02:45 | FAILED | | | | THE OAKTON PRESERVE RPD ONLY PERMITS SCREENED | | ENCLOSURES AND NOT SCREEN ROOMS WITH A SOLID ROOF. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|