Plan Review Stops For Permit 13050197 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2013-06-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-06-06 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-06-06 |
Time |
12:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2013-06-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-06-04 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-06-04 |
Time |
13:39 |
Sent To |
|
|
Notes |
2013-06-04 13:40:07 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- REVISE ENERGY CALCULATIONS. ACCORDING TO INFORMATION | | SUBMITTED AND WINDOW NOTE #2 FROM TABLE 402.A NEED TO | | USE FORM 405 TO COMPLY. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-05-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-05-17 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-05-17 |
Time |
10:37 |
Sent To |
|
|
Notes |
2013-05-17 13:31:59 | RESIDENTIAL (R3) RENOVATIONS, BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | 101.4 OF 2010 FBC-ENERGY CONSERVATION. | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9N-3 FOR: | | A) WINDOW MULLIONS, INCLUDING WINDOW MULLIONS FOR BAY | | WINDOW IN DINING AREA. | | | | B) ROOF RIDGE VENT. | | | | C) FLAT ROOF. NOA 12-0227.18 SUBMITTED WAS SUPERSEDED | | BY MIAMI-DADE. VISIT THE MIAMI DADE WEBSITE AND | | DOWNLOAD CURRENT NOA. | | AND, PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT | | PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL | | LIMITATION #7 TO MEET THE DESIGN PRESSURES OF SEC. | | R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL. | | | | ***NOTE: IF NOA SUBMITTED REQUIRES RAS 117 CALCULATIONS | | TO BE SIGNED AND SEALED, THEN PROVIDE SIGNED AND SEALED | | RAS 117 CALCULATIONS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2013-05-28 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-05-28 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-05-28 |
Time |
08:48 |
Sent To |
|
|
Notes |
2013-05-28 08:48:51 | 5-28-13 | | CORRECTIONS MADE ! | | VB |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-05-14 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-05-14 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-05-14 |
Time |
09:22 |
Sent To |
|
|
Notes |
2013-05-14 09:29:58 | 5-14-13 | | | | 1. ALL ELECTRIC TO MEET 2008 NEC | | 2. ALL NEW RECEPTS TO BE TAMPER RESISTANT PER NEC | | 406.11 | | 3. SHOW "NEW" AND "EXISTING" DEVICES ON DRAWINGS | | 4. INSTALL AFCI BREAKERS PER NEC 210.12B | | 5. SMOKE ALARMS AS REQUIRED BY RBC 315 MUST HAVE CO | | PROTECTION AS WELL AS SMOKE. | | 6. NEC TABLE 310.15 B6 SHOWS CONDUCTORS TO A 150A | | SERVICE TO BE #1, NOT #2 | | VB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-06-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-06-04 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-05-24 |
Time |
11:43 |
Sent To |
|
|
Notes |
2013-05-25 11:44:01 | GAVE TO VINNEY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-05-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-05-17 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-05-07 |
Time |
14:52 |
Sent To |
|
|
Notes |
2013-05-08 14:53:24 | SENT TO R14 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2013-05-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-05-17 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-05-17 |
Time |
12:31 |
Sent To |
|
|
Notes |
2013-05-17 13:06:55 | MECHANICAL REVIEW APPROVED WITH PROVISO: | | | | 1- PROVIDE COMPLETE A/C CHANGE OUT FORM BEFORE | | INSPECTION. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2013-05-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2013-05-17 |
Time |
12:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2013-05-17 |
Time |
12:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2013-05-10 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2013-05-10 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2013-05-10 |
Time |
10:30 |
Sent To |
|
|
Notes |
|
|