Plan Review Stops For Permit 13050152 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2013-07-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-07-05 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-07-05 |
Time |
13:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-05-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-05-15 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-05-15 |
Time |
13:47 |
Sent To |
|
|
Notes |
2013-05-15 14:17:39 | BUILDING PLAN REVIEW | | PERMIT: 13050152 | | ADD: 101 N CLEMATIS ST SUITE # 100 | | CONT: TBD | | TEL: (813)833-3128 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: MAY 15/ 2013 | | ACTION: DENIED | | | | 1) ADDITIONAL INFORMATION IS REQUIRED, THE PERMIT | | APPLICATION INDICATES THE RENOVATION IS TO BE A DISPLAY | | KITCHEN, IS THIS A WORKING KITCHEN WHERE FOOD WILL BE | | COOKED? | | THE BAR EXTENSION EXTENSION IS INDICATED TO BE 3'-6" | | TALL, PLEASE PROVIDE COMPLIANCE FOR 2010 FL | | ACCESSIBILITY CODE FOR EITHER 902.4.2 HEIGHT OR | | 904.5.2, THE PLANS ARE NOT CLEAR IF THE BAR EXTENSION | | WILL BE USED BY THE STAFF OR IF IT WILL BE USED BY THE | | PATRONS? PLEASE REVIEW 226.2 DISPERSION PROVIDE CODE | | COMPLIANCE. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2013-07-02 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-07-02 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-07-02 |
Time |
11:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-05-06 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-05-06 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-05-06 |
Time |
16:00 |
Sent To |
|
|
Notes |
2013-05-06 16:03:18 | 5-06-13 | | 1. PROVIDE ENGINEERED DRAWING FOR CEILING MOUNTER 30KVA | | TRANSFORMER | | 2. PROVIDE PANEL SCHEDULE FOR MSB. SHOW AIC AND FAUILT | | CURRENT NEC 110.9 & 110.10 | | 3. IS PANEL SCHEDULED SHOWN ON E4 "K" OR "K2"? PLEASE | | SHOW BOTH SCHEDULES. NEC 408.4 | | VB |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2013-06-20 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-06-20 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-06-20 |
Time |
15:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2013-05-16 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-05-16 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-05-16 |
Time |
13:18 |
Sent To |
|
|
Notes |
2013-05-16 13:29:00 | 101 NORTH CLEMATIS STREET - #100 | | PERMIT #13050152 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | SUBMIT PRODUCT DATA FOR FUTURE VENTLESS FRYER COMPLYING | | WITH FBCM 507.1(#2); OTHERWISE THE FOLLOWING WILL BE | | REQUIRED: | | | | DEEP FAT FRYER: COOKING OPERATIONS PRODUCING SMOKE OR | | GREASE-LADEN VAPORS SHALL BE PROTECTED WITH A CLASS I | | MECHANICAL EXHAUST HOOD EQUIPPED WITH AN AUTOMATIC | | WET-CHEMICAL FIRE SUPPRESSION SYSTEM. | | | | DEEP FAT FRYERS SHALL BE EQUIPPED WITH A SEPARATE | | HIGH-LIMIT CONTROL IN ADDITION TO THE ADJUSTABLE | | THERMOSTAT TO SHUT OFF FUEL OR ENERGY WHEN THE FAT | | TEMPERATURE REACHES 475F DEGREES AT 1-INCH BELOW THE | | SURFACE. | | | | PER FBC 904.11.1, A MANUAL ACTIVATION DEVICE SHALL BE | | LOCATED ALONG THE EGRESS PATH AND BE A MINIMUM OF 10 | | FEET AND A MAXIMUM OF 20 FEET FROM THE KITCHEN EXHAUST | | SYSTEM. THE DEVICE SHALL BE MOUNTED 42-48 INCHES ABOVE | | THE FLOOR AND SHALL CLEARLY IDENTIFY THE HAZARD | | PROTECTED. | | | | PROVIDE A K-TYPE PORTABLE FIRE EXTINGUISHER AND | | ASSOCIATED SIGNAGE IN KITCHEN AREA. | | | | KITCHEN HOOD SUPPRESSION SYSTEM SHALL BE TIED INTO THE | | BUILDING FIRE ALARM SYSTEM TO INITIATE A GENERAL FIRE | | ALARM CONDITION. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-07-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-07-05 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-06-12 |
Time |
14:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-05-28 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-05-28 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-05-06 |
Time |
11:30 |
Sent To |
|
|
Notes |
2013-05-07 10:07:05 | TO B13 | 2013-05-06 11:31:02 | INCOMING SENT TO B-03 BOX. JW |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2013-05-28 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-05-28 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-05-28 |
Time |
14:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2013-05-08 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-05-08 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-05-08 |
Time |
11:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2013-05-22 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2013-05-22 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2013-05-22 |
Time |
10:27 |
Sent To |
|
|
Notes |
2013-05-22 10:27:51 | INTERIOR IMPROVEMENTS FOR NEW DISPLAY KITCHEN. | 2013-05-10 10:38:27 | 5/10/13 |
|
|