Plan Review Details - Permit 13050046
Plan Review Stops For Permit 13050046 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2013-05-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-05-16 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-05-16 |
Time |
17:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-05-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-05-10 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-05-10 |
Time |
13:06 |
Sent To |
|
|
Notes |
2013-05-10 13:06:38 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | FROM PREVIOUS LIST: | | | | 1. THIS APPEARS TO BE LOCATED IN EXPOSURE C, SEE FBC R | | 301.2.1.4.3. REVISE WIND LOAD CHART AND INSTALLATION | | SCHEDULE ACCORDINGLY. | | | | 2ND REVIEW - REVISED WIND LOAD CHART PROVIDED, BUT | | INSTALLATION SCHEDULE WAS NOT REVISED. DESIGN PRESSURES | | ON INSTALLATION SCHEDULE TO COMPLY WITH EXPOSURE C | | REQUIREMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-05-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-05-07 |
Time |
12:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-05-07 |
Time |
12:21 |
Sent To |
|
|
Notes |
2013-05-07 12:22:18 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. THIS APPEARS TO BE LOCATED IN EXPOSURE C, SEE FBC R | | 301.2.1.4.3. | | | | REVISE PROPOSED WIND DESIGN PRESSURES AND INSTALLATION | | SCHEDULE ACCORDINGLY. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-05-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-05-16 |
Time |
17:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-05-16 |
Time |
13:31 |
Sent To |
|
|
Notes |
2013-05-16 13:31:30 | INCOMING SENT TO SAMANTHAS' DESK . JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-05-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-05-07 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-05-01 |
Time |
11:15 |
Sent To |
|
|
Notes |
2013-05-02 11:15:35 | SENT TO BUILDING UNDER $5000 SHELF FOR REVIEW. JG. |
|
|
|