Plan Review Details - Permit 13040768
Plan Review Stops For Permit 13040768 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2013-04-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-04-29 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-04-26 |
Time |
14:21 |
Sent To |
|
|
Notes |
2013-04-29 09:13:07 | BUILDING PLAN REVIEW | | PERMIT: 13040768 | | ADD:777 S FLAGLER # 140E | | CONT: BUTLER CONSTRUCTION CO. | | TEL: (561)832-9700 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: 4-29/2013 | | ACTION: BUILDING PROVISO | | | | 1) EXISTING GLASS DOORS BETWEEN THE VESTIBULE 100 & | | RECEPTION ROOM 101 SWING THE WRONG WAY TO BE CONSIDERED | | PART OF AN EXIT. THE COVERSHEET HAS AN EXIT LIGHT | | DIRECTLY ABOVE THESE DOORS, TO MAKE THIS A CODE | | COMPLIANT ELEMENT EITHER: | | 1) REMOVE THE EXIT LIGHT ABOVE THE GLASS DOORS, IS NOT | | REQUIRED TO BE A MEANS OF EGRESS OR, | | 2) REVERSE THE SWING OF THE DOORS TO OUT SWING DOORS. | | 2010 FBC-B 1008.1.2 DOOR SWING- DOORS SHALL SWING IN | | THE DIRECTION OF EGRESS TRAVEL WHERE SERVING AN | | OCCUPANT LOAD OF 50 OR MORE PERSONS OR A GROUP H | | OCCUPANCY. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2013-05-07 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-05-07 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-05-07 |
Time |
13:47 |
Sent To |
|
|
Notes |
2013-05-07 13:48:51 | 5-7-13 | | ALL ELECTRICAL DEMO MUST BE MAD SAFE., ALL ABANDONED | | CONDUITS MUST BE REMOVED FROM CEILING OR CUT FLUSH WITH | | THE FLOOR AND CAPPED. ANY CONDUCTORS MUST BE REMOVED | | BACK TO THE SOURCE. | | VB |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2013-04-29 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-04-29 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-04-29 |
Time |
13:11 |
Sent To |
|
|
Notes |
2013-04-29 13:18:45 | SEE BUILDING DEPARTMENT COMMENT REGARDING DOOR SWING AT | | VESTIBULE 100. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-05-08 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-05-08 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-04-19 |
Time |
08:48 |
Sent To |
|
|
Notes |
2013-04-22 08:48:40 | SENT TO B6 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2013-05-08 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-05-08 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-05-08 |
Time |
14:10 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |