Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-04-18 Cont ID  
Sent By rmcdouga Date 2013-04-18 Time 09:50 Rev Time 0.00
Received By rmcdouga Date 2013-04-18 Time 09:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-04-12 Cont ID  
Sent By rmcdouga Date 2013-04-12 Time 15:13 Rev Time 0.00
Received By rmcdouga Date 2013-04-11 Time 15:13 Sent To  
Notes
2013-04-12 15:17:242010 FBC
  
 DENIED BY BUILDING
  
 1) THE SBS MODIFIED ROOF SYSTEM ON PAGE 31 OF PRODUCT
 APPROVAL NOA NO.08-0410.09 HAS A MAXIMUM DESIGN
 PRESSURE OF -45 PSF AND LIMITATION #9 WHICH DOES NOT
 ALLOW ENHANCED FASTENING TO INCREASE THE DESIGN
 PRESSURE. THIS PRESSURE IS TOO LOW FOR THE PERIMETER
 AND CORNER AREAS FOR A FLAT ROOF ON A STRUCTURE LOCATED
 IN EXPOSURE CATEGORY C WITH A 170 MPH ULTIMATE / 132
 NOMINAL WIND SPEED. PLEASE SELECT A SYSTEM WITH
 ADEQUATE DESIGN PRESSURES OR ONE THAT ALLOWS ENHANCED
 FASTENING. NOTE: RAS 117 CALCULATIONS FOR ENHANCED
 FASTENING ARE REQUIRED TO BE SIGNED AND SEALED BY A
 FLORIDA LICENSED DESIGN PROFESSIONAL PER LIMITATION #7
 OF THIS NOA. DCA RULE 9N-3 AND FBCR301.2.1
  
 2) TWO COPIES OF PRODUCT APPROVALS AND CALCULATIONS ARE
 REQUIRED TO BE SUBMITTED FOR PERMIT. CITY AMENDMENTS
 107.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-04-18 Cont ID  
Sent By rmcdouga Date 2013-04-18 Time 09:50 Rev Time 0.00
Received By rmcdouga Date 2013-04-17 Time 16:01 Sent To  
Notes
2013-04-17 16:01:35SENT TO R MCDOUGAL


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved