Plan Review Details - Permit 13040263
Plan Review Stops For Permit 13040263 |
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2013-04-22 |
Time |
|
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-04-19 |
Time |
14:24 |
Sent To |
M |
|
Notes |
2013-04-19 15:02:34 | VOLTAGE DROP CALCULATION DOES NOT SEEM TO MATCH | | REQUIRED VOLTAGE RATING AND PROPOSED EQUUIPMENT. IS | | ANNUNCIATION PHASED, 2 ABOVE AND ONE BELOW FLOOR OF | | INITIATION? | | ADDED MECHANICAL STOP FOR DUCT DETECTORS | | DOES NOT APPEAR PULL STATIONS ARE LOCATED AT EACH POINT | | OF NATURAL ESCAPE? RECREATION ROOM, MAINTENANCE ROOM | | CALLED ENGINEER REGARDING VD. HE DID NOT HAVE THE | | DRAWINGS AT THIS TIME. WILL REVIEW AND CALL ME BACK | | SPOKE WITH DESIGN ENGINEER. CALCULATIONS AND VOLTAGES | | APPEAR OK BASED ON CONVERSATION AND EXPECTED VOLTAGES | | OF EQUIPMENT TO BE VERIFIED IN THE FIELD. BATTERY POWER | | APPEARS TO BE SUFFICIENT BASED ON DRAW OF PROPOSED | | DEVICES. SPOKE TO WESLEY ON PULL STATIONS AND THIS | | SEEMS TO BE OK AS IT IS A SPRINKLERED BUILDING. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2013-04-15 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-04-15 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-04-15 |
Time |
10:20 |
Sent To |
E |
|
Notes |
2013-04-15 10:59:15 | 1900 CONSULATE PLACE | | PERMIT #13040263 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | PLANS DO NOT INDICATE THE METHOD (HEAT DETECTOR/FLOW | | SWITCH WITHOUT TIME DELAY) USED TO SHUNT TRIP POWER TO | | THE ELEVATOR IN THE EVENT AN AUTOMATIC SPRINKLER | | ACTIVATES IN THE ELEVATOR MACHINE ROOM. | | | | PROVIDE A PRE-RECORDED FIRE ALARM EVACUATION MESSAGE | | NOTIFYING OCCUPANTS AN EMERGENCY HAS BEEN REPORTED IN | | THE BUILDING, LOCATE THE NEAREST EXIT, AND EXIT THE | | BUILDING IMMEDIATELY. DO NOT USE THE ELEVATOR. | | | | PER LOCAL AHJ POLICY, DUCT SMOKE DETECTORS SHALL | | INITIATE A GENERAL FIRE ALARM CONDITION. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-04-24 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-04-24 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-04-08 |
Time |
07:36 |
Sent To |
|
|
Notes |
2013-04-09 07:36:57 | INCOMING SENT TO FIRE BOX. JW |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2013-04-24 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-04-24 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-04-24 |
Time |
13:08 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |