Plan Review Stops For Permit 13040109 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2013-06-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-06-04 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-06-04 |
Time |
11:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-04-19 |
|
|
Cont ID |
|
Sent By |
RMCDOUGA |
Date |
2013-04-19 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-04-19 |
Time |
14:17 |
Sent To |
|
|
Notes |
2013-04-19 15:27:16 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) SHEET A-1 OF THE REVISED PLANS CONTAINS SEVERAL | | CHANGES THAT WERE NOT CLOUDED AND NUMBERED. (1) THE | | WINDOWS AT THE FIRST FLOOR DINING ROOM HAVE BEEN | | REMOVED AND A DOUBLE OUTSWING FRENCH DOOR IS SHOWN AT | | THIS LOCATION. (2) THE SECOND FLOOR BATHROOMS WERE | | CHANGED. (3) THE SECOND FLOOR COVERED PORCH IS SHOWN AS | | BEING ENCLOSED. PLEASE CLOUD AND NUMBER THE ITEMS THAT | | HAVE BEEN CHANGED FROM THE APPROVED PLANS. CITY | | AMENDMENTS 107.2.1 | | NOTE: AN IMPACT FEE REVIEW BY PALM BEACH COUNTY WILL BE | | REQUIRED TO DETERMINE IF FEES ARE DUE FOR THE ADDED | | LIVING SPACE OF THE ENCLOSED SECOND FLOOR PORCH. | | | | 2) SUBMIT PRODUCT APPROVALS FOR THE NEW EXTERIOR | | WINDOWS, DOORS AND (IMPACT PROTECTION) AS REQUIRED BY | | DCA RULE 9N-3. | | | | 3) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. CITY | | AMENDMENTS 107.3.4.1 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2013-05-31 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-05-31 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-05-31 |
Time |
13:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2013-06-04 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-06-04 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-06-04 |
Time |
11:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2013-04-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-04-11 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-04-10 |
Time |
|
Sent To |
|
|
Notes |
2013-04-11 14:31:53 | FAILED PER COMMENTS ON PERMIT 13030480. REQUIRES | | HISTORIC PRESERVATION BOARD APPROVAL WITH A CERTIFICATE | | OF APPROPORIATENESS APPLICATION. QUESTIONS CONTACT | | FRIEDERIKE MITTNER, CITY HISTORIC PRESERVATION PLANNER | | 822-1457. | 2013-04-10 14:45:14 | GAVE TO F.M. - MD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-06-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-06-04 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-05-14 |
Time |
13:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-04-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-04-19 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-04-02 |
Time |
08:43 |
Sent To |
|
|
Notes |
2013-04-03 08:43:30 | INCOMING SENT TO R11 BOX. JW |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2013-06-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-06-04 |
Time |
12:16 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-06-04 |
Time |
12:15 |
Sent To |
|
|
Notes |
2013-06-04 12:16:43 | NO FEES DUE |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2013-04-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-04-19 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-04-19 |
Time |
14:22 |
Sent To |
|
|
Notes |
2013-04-19 14:25:39 | IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED. ONE | | SET OF PLANS IS TO BE SIGNED OUT AND TAKEN TO PBC. | | AFTER THE PLAN IS REVIEWED AND STAMPED BY PBC, IT IS TO | | BE RETURNED TO THE CITY BUILDING DEPARTMENT. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2013-06-04 |
|
|
Cont ID |
|
Sent By |
H MOSER |
Date |
2013-04-17 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-04-17 |
Time |
13:31 |
Sent To |
|
|
Notes |
2013-06-04 11:58:01 | THERE IS A SEPARATE MECHANICAL PERMIT (# 13020617) WITH | | SEPARATE PLANS AND REVIEWS FOR THIS PROJECT. ANY | | REVISIONS ARE REQUIRED TO BE SUBMITTED UNDER THE | | SEPARATE MECHANICAL PERMIT. THE MECHANICAL PLANS HAVE | | BEEN CROSSED OFF THESE PLANS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2013-06-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-06-04 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-06-04 |
Time |
11:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2013-04-03 |
|
|
Cont ID |
|
Sent By |
L WAGNER |
Date |
2013-04-03 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-04-03 |
Time |
12:01 |
Sent To |
|
|
Notes |
2013-04-03 12:10:39 | RE-STAMPED |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2013-04-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-04-11 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-04-11 |
Time |
14:32 |
Sent To |
|
|
Notes |
2013-04-10 11:49:07 | 4/10/13 |
|
|