Plan Review Details - Permit 13040093
Plan Review Stops For Permit 13040093 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-04-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-04-23 |
Time |
17:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-04-23 |
Time |
17:06 |
Sent To |
|
|
Notes |
2013-04-23 17:07:22 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 2ND REVIEW - SOUND TRANSMISSION TEST REPORTS WERE | | SUBMITTED. COMMENTS FROM FIRST REVIEW (SEE BELOW) ARE | | REGARDING FLAME SPREAD. | | | | 1. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM | | E 84 OR UL 723. | | | | IF THE DOC-FF-1-70 (TEST REFERRED TO ON THE DOCUMENT | | SUBMITTED) WOULD LIKE TO BE PRESENTED AS ALTERNATIVE | | MATERIALS AND METHODS, SUBMIT A COPY OF THE ACTUAL TEST | | REPORT WITH AN ANALYSIS OF HOW THIS TEST MEETS OR | | EXCEEDS THE REQUIREMENTS OF ASTM E 84 OR UL 723. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-04-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-04-08 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-04-08 |
Time |
13:42 |
Sent To |
|
|
Notes |
2013-04-08 13:44:54 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM | | E 84 OR UL 723. | | | | IF THE DOC-FF-1-70 (TEST REFERRED TO ON THE DOCUMENT | | SUBMITTED) WOULD LIKE TO BE PRESENTED AS ALTERNATIVE | | MATERIALS AND METHODS, SUBMIT A COPY OF THE ACTUAL TEST | | REPORT WITH AN ANALYSIS OF HOW THIS TEST MEETS OR | | EXCEEDS THE REQUIREMENTS OF ASTM E 84 OR UL 723. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-04-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-04-23 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-04-18 |
Time |
16:33 |
Sent To |
|
|
Notes |
2013-04-18 16:41:04 | GAVE TO SAMANTHA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-04-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-04-08 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-04-03 |
Time |
08:12 |
Sent To |
|
|
Notes |
2013-04-03 08:13:56 | INCOMING SENT TO <$5K BUILDING BOX. JW |
|
|
|