Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-04-26 Cont ID  
Sent By lmartine Date 2013-04-26 Time 14:33 Rev Time 0.00
Received By lmartine Date 2013-04-26 Time 14:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-03-30 Cont ID  
Sent By lmartine Date 2013-03-30 Time 11:35 Rev Time 0.00
Received By lmartine Date 2013-03-30 Time 11:35 Sent To Z
Notes
2013-03-30 11:43:53BUILDING REVIEW COMMENTS
  
  
 STOREFRONT WORK IS OK.
  
 EXPLAIN SHEET A-3. THE WORK IDENTIFIED AT THE REAR
 ELEVATION IS NOT DESCRIBED ON THE PERMIT APPLICATION.
  
 THE PLANS SUBMITTED HAVE TWO DIFFERENT ENGINEERS
 SIGNATURES AFFIXED, PLEASE HAVE ONLY ONE ENGINEER OF
 RECORD.
  
  
  
 LUIS MARTINEZ
 561-805-6710
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2013-04-23 Cont ID  
Sent By fmittner Date 2013-04-23 Time 18:49 Rev Time 0.00
Received By fmittner Date 2013-04-23 Time 18:49 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2013-03-21 Cont ID  
Sent By jroach Date 2013-03-21 Time 15:07 Rev Time 0.00
Received By jroach Date 2013-03-21 Time 15:07 Sent To B
Notes
2013-03-21 15:10:18PROPOSED IMPROVEMENTS REQUIRE THE APPROVAL OF A
 CERTIFICATE OF APPROPRIATENESS FROM THE CITY'S HISTORIC
 PRESERVATION BOARD PRIOR TO ISSUANCE OF A BUILDING
 PERMIT. APPLICATION HAS ALREADY BEEN SUBMITTED, BUT
 WILL NEED TO BE APPROVED PRIOR TO PASSING OF THE PERMIT
 APPLICATION. APPLICATION IS BEING ROUTED TO ALL OTHER
 TRADES FOR REVIEW.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL
 PLANNER, AT (561) 822-1448
  
 OR
  
 FRIEDERIKE MITTNER, CITY HISTORIC PRESERVATION PLANNER,
 AT (561) 822-1457.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-04-26 Cont ID  
Sent By lmartine Date 2013-04-26 Time 14:04 Rev Time 0.00
Received By lmartine Date 2013-04-23 Time 08:20 Sent To  
Notes
2013-04-24 09:02:394/24 ROUTED ORIGINAL APP/PLAN (RETURNED FROM HISTORIC)
 TO LM DESK
  
2013-04-24 08:21:20SENT TO LUIS MARTINEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-04-26 Cont ID  
Sent By lmartine Date 2013-03-30 Time 14:26 Rev Time 0.00
Received By lmartine Date 2013-03-21 Time 16:10 Sent To  
Notes
2013-03-21 16:12:43MISC. #1

Review Stop Z ZONING
Rev No 1 Status P Date 2013-04-23 Cont ID  
Sent By fmittner Date 2013-04-23 Time 18:49 Rev Time 0.00
Received By fmittner Date 2013-04-23 Time 18:49 Sent To  
Notes
***NONE***