Plan Review Stops For Permit 13020219 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2013-03-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-03-29 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-03-29 |
Time |
10:25 |
Sent To |
|
|
Notes |
2013-03-29 10:41:15 | ****PROVISOS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | COMMENTS FROM PREVIOUS LIST: | | | | 1. SPEC SHEET REFERS TO A NEW CLOSET AND DOOR, NOT | | SHOWN ON PLAN. CONFIRM THAT THIS HAS BEEN REMOVED FROM | | SCOPE OR REVISE PLAN TO SHOW ALL WORK PROPOSED, FBC | | 107. | | | | 2. ENGINEER TO PROVIDE AN INDEX SHEET USING CURRENT | | SEAL (OLD SEAL USED ON PLANS INADVERTENTLY); | | FAC61G15-23.002. | | | | 3. ENGINEER TO PROVIDE LETTERS PRINTED ON ENGINEER'S | | LETTERHEAD RATHER THAN GLADES ROOFING LLC LETTERHEAD | | FAC61G15-23.002. | | | | 4. ENERGY CALCS NOT SIGNED AND ARE LACKING THE HEATING | | EQUIPMENT INFORMATION, SUBMIT AS A REVISION. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-03-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-03-21 |
Time |
07:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-03-21 |
Time |
07:03 |
Sent To |
|
|
Notes |
2013-03-21 07:28:39 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | COMMENTS FROM PREVIOUS LIST: | | | | 1-2. OK | | | | 3. SPEC SHEET REFERS TO A NEW CLOSET AND DOOR, NOT | | SHOWN ON PLAN. CONFIRM THAT THIS HAS BEEN REMOVED FROM | | SCOPE OR REVISE PLAN TO SHOW ALL WORK PROPOSED, FBC | | 107. | | | | 4. OK | | | | 5. PROVIDE FLORIDA STATE OR LOCAL PRODUCT APPOVAL FOR | | THE FLAT DECK. PROVIDE ROOF HEIGHT AND SLOPE. FOR THE | | ROOF, INDICATE WHICH APPROVED ASSEMBLY IS PROPOSED AND | | PROVIDE ENGINEERING IF REQUIRED OR OTHERWISE SPECIFY | | ENHANCED FASTENING, SEE LIMITATIONS ON THE PRODUCT | | APPROVAL. A SEPARATE ROOF SUB PERMIT IS REQUIRED. | | | | PLEASE NOTE THAT INSULATION BOARD IS REQUIRED PER | | SPECIFICATION. | | | | ROOF INFORMATION MAY BE PROVIDED UNDER A SEPARATE STAND | | ALONE PERMIT. PLEASE ADVISE IF YOU WISH FOR THIS SCOPE | | TO BE REMOVED FROM THIS PERMIT. | | | | 2ND REVIEW, TWO DIFFERENT ASSEMBLIES HIGHLIGHTED | | (SHEETS 8 AND 11), SEE GENERAL LIMITATION #7, | | CALCULATIONS IN ACCORDANCE WITH RAS 117 TO BE | | CALCULATED BY AN ARCHITECT, ENGINEER, OR REGISTERED | | ROOF CONSULTANT, FBC R 301. | | | | 6-7. OK | | | | NEW COMMENT: | | | | ENGINEER'S SEAL TO BE IN ACCORDANCE WITH FBPE BOARD | | RULES, FS 471, FAC61G-15.23. SEAL TO STATE "LICENSE" | | RATHER THAN "CERTIFICATE" (RULE CHANGED SEVERAL YEARS | | AGO). | | | | IT IS NOT CLEAR WHETHER THE ENGINEER IS WORKING THROUGH | | THE COMPANY GLADES ROOFING LLC. ENGINEER'S LETTER | | APPROVING PRODUCT APPROVALS IS NOT SEALED AND IS ON | | GLADES ROOFING LLC'S LETTERHEAD. IF THE ENGINEER IS | | PRACTICING ENGINEERING THROUGH THIS COMPANY, A | | CERTIFICATE OF AUTHORIZATION IS REQUIRED FS471. IF THE | | ENGINEER IS NOT, EITHER PROVIDE THE LETTER ON THE | | ENGINEER'S LETTERHEAD OR EXPLAIN WHY THE ENGINEER IS | | USING THE CONTRACTOR'S LETTERHEAD FOR BUILDING | | SPECIFICATIONS. | | | | ENERGY CALCS NOT SIGNED AND ARE LACKING THE HEATING | | EQUIPMENT INFORMATION. | | | | NEW COMMENT: | | | | UPON REQUEST, OUTSTANDING ITEMS CAN BE PROVISO ITEMS | | (REVISION REQUIRED PRIOR TO FIRST INSPECTION). PERMIT | | WILL BE ISSUED AT CONTRACTOR'S RISK. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-02-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-02-12 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-02-12 |
Time |
11:27 |
Sent To |
|
|
Notes |
2013-02-12 11:37:22 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. SEE FBC 107.2.1: | | | | INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION | | DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON SUITABLE | | MATERIAL. ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED | | WHEN APPROVED BY THE BUILDING OFFICIAL. CONSTRUCTION | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED | | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | | NO PLAN SUBMITTED. | | | | 2. PLEASE DO NOT SUBMIT DOCUMENTS NOT REQUIRED TO SHOW | | CODE COMPLIANCE. FOR INSTANCE, THE DOCUMENT REGARDING | | LEAD BASED PAINT. | | | | 3. PROVIDE A STRUCTURAL DETAILS FOR STAIRS, RAILINGS, | | COLUMNS, NEW INTERIOR DOOR FRAMING (AS WELL AS INCLUDE | | LOCATIONS ON A FLOOR PLAN), FBC R 301. | | | | 4. PROVIDE FLORIDA STATE OR LOCAL PRODUCT APPROVAL FOR | | THE DOORS AND WINDOWS, FAC9N-3. | | | | 5. PROVIDE FLORIDA STATE OR LOCAL PRODUCT APPOVAL FOR | | THE FLAT DECK. PROVIDE ROOF HEIGHT AND SLOPE. FOR THE | | ROOF, INDICATE WHICH APPROVED ASSEMBLY IS PROPOSED AND | | PROVIDE ENGINEERING IF REQUIRED OR OTHERWISE SPECIFY | | ENHANCED FASTENING, SEE LIMITATIONS ON THE PRODUCT | | APPROVAL. A SEPARATE ROOF SUB PERMIT IS REQUIRED. | | | | PLEASE NOTE THAT INSULATION BOARD IS REQUIRED PER | | SPECIFICATION. | | | | ROOF INFORMATION MAY BE PROVIDED UNDER A SEPARATE STAND | | ALONE PERMIT. PLEASE ADVISE IF YOU WISH FOR THIS SCOPE | | TO BE REMOVED FROM THIS PERMIT. | | | | 6. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING | | CANNOT BE REDUCED BY MORE THAN 5%. INCLUDE DOOR | | LOCATIONS FOR DOORS TO BE REPLACED AS WELL AS DOOR | | SIZE. | | | | 7. REAR UNIT REQUIRES ALL INFORMATION AS NOTED ABOVE TO | | BE INCLUDED IN A SEPARATE PERMIT APPLICATION. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2013-04-01 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2013-04-01 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2013-04-01 |
Time |
11:25 |
Sent To |
|
|
Notes |
2013-04-01 12:40:27 | | | 13020219 | | 817 21ST STREET | | RESIDENTIAL REPAIR | | | | THE PERMIT WAS APPROVED WITH THE FOLLOWING REQUIREMENTS | | LISTED ON THE PLAN. | | | | PROVISO | | | | KITCHEN COUNTER TOP RECEPTACLES TO BE GFCI PROTECTED. | | NEC 210.8 | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND | | OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS | | APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON | | MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH | | ROOM USED FOR SLEEPING. 2010 FBC R314, 315 | | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | | ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW | | GENERAL PURPOSE OUTLETS INCLUDING LIGHTING. NEC 210.12 | | | | THE BATHROOM REQUIRES A DEDICATED 20 AMP BRANCH | | CIRCUIT. NEC 210.11 (C) (3) | | | | A GFCI PROTECTED RECEPTACLE IS REQUIRED OUTSIDE AT THE | | FRONT AND BACK ENTRANCE AREA. NEC 210.52 (E) (1) | | | | AN INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN | | SERVICE GROUND. NEC 250.94 | | | | | | ROBERT LECKY | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6718 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-02-20 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2013-02-20 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2013-02-20 |
Time |
15:55 |
Sent To |
P |
|
Notes |
2013-02-20 16:27:28 | 13020219 | | 817 21ST STREET | | RESIDENTIAL REPAIR | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | ELECTRICAL REVIEW COMMENTS. | | | | ELECTRICAL PLANS ARE REQUIRED. PROVIDE AN ELECTRICAL | | RISER PLAN SHOWING THE PANEL, MAIN BREAKER, GROUNDING, | | FEEDERS AND BRANCH CIRCUITS. INCLUDE A LOAD CALCULATION | | AND PANEL DIRECTORY. SHOW LOCATION OF THE ELECTRICAL | | PANEL WITH REQUIRED SAFE WORKING CLEARANCES. | | INDICATE THE SIZE AND LOCATION OF THE ELECTRICAL PANEL. | | ON A FLOOR PLAN SHOW THE LOCATION OF ALL NEW LIGHTING | | OUTLETS, RECEPTACLE OUTLETS AND SMOKE DETECTORS. NEC | | 215.5, 210.50, 110.26 | | | | SHOW SAFETY CLEARANCES AND LOCATIONS OF ALL APPLIANCES, | | PANEL BOARDS, METERS ETC. FBC 107.2.1 | | | | SHOW THE KITCHEN COUNTER TOP RECEPTACLES TO BE GFCI | | PROTECTED. NEC 210.8 | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND | | OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS | | APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON | | MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH | | ROOM USED FOR SLEEPING. 2010 FBC R314, 315 | | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | | ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW | | GENERAL PURPOSE OUTLETS INCLUDING LIGHTING. NEC 210.12 | | | | THE BATHROOM REQUIRES A DEDICATED 20 AMP BRANCH | | CIRCUIT. NEC 210.11 (C) (3) | | | | A GFCI PROTECTED RECEPTACLE IS REQUIRED OUTSIDE AT THE | | FRONT AND BACK ENTRANCE AREA. NEC 210.52 (E) (1) | | | | | | ROBERT LECKY | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6718 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-04-02 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-04-02 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-03-18 |
Time |
08:53 |
Sent To |
|
|
Notes |
2013-03-20 09:20:56 | R--1 | 2013-03-20 09:20:38 | EXPEDITED | | (CITY HOUSING) |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-02-25 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-02-25 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-02-08 |
Time |
10:14 |
Sent To |
|
|
Notes |
2013-02-12 11:38:58 | 2/11 TO ZONING | | | 2013-02-11 10:23:01 | SENT TO MISC 1 BOX PER L MARTINEZ. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2013-03-21 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-03-21 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-03-21 |
Time |
08:45 |
Sent To |
|
|
Notes |
2013-03-21 09:03:53 | PROVISO | | | | ANY CHANGES TO DUCTWORK WILL REQUIRE A PLAN SUBMITTED | | AS A REVISION | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2013-02-25 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-02-25 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-02-25 |
Time |
12:49 |
Sent To |
|
|
Notes |
2013-02-25 13:07:05 | DENIED | | 1) REFER TO SECTION 107.2.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS | | 2010 FBC. | | 2) ANY NEW MECHANICAL WORK REQUIRES A MECHANICAL PLAN. | | PER SECTION 107.3.5.3 (10) AND ( 13 ) 2010 FBC | | PLAN REVIEW BY HAROLD MOSER | | 561-805-6732 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2013-04-02 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-04-02 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-04-02 |
Time |
10:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2013-02-22 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-02-22 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-02-22 |
Time |
14:31 |
Sent To |
|
|
Notes |
2013-02-22 15:00:45 | FBC 2010 EXISTING BUILDING CODE | | FBC 2010 PLUMBING REVIEW #1 | | DENIED: | | | | 1. PLEASE SEE BUILDING REVIEW NOTES FOR FBC 107.2.1: | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 2. ANY NEW PLUMBING PIPEING REQUIRES A PLUMBING | | DRAWING. | | FBC 107.3.5.3 (11) | | | | REVIEW BY | | LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | PHONE # 805-6692 | | EMAIL [email protected] | | FAX # 805-6676 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2013-02-11 |
|
|
Cont ID |
|
Sent By |
mdekle |
Date |
2013-02-11 |
Time |
|
Rev Time |
|
Received By |
mdekle |
Date |
2013-02-11 |
Time |
|
Sent To |
E |
|
Notes |
|
|