Plan Review Stops For Permit 13020210 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2013-05-23 |
|
|
Cont ID |
|
Sent By |
JWITMER |
Date |
2013-05-23 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-05-23 |
Time |
07:04 |
Sent To |
|
|
Notes |
2013-05-23 07:46:55 | BUILDING PLAN REVIEW | | PERMIT:13020210 | | ADD: 701 S ROSEMARY AVE. SUITE # NOT PROVIDED | | CONT: LAKEVIEW CONSTRUCTION | | TEL: (561)635-6935 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | CITY PLACE MANAGEMENT | | CARLOS BERNEL | | 561-820-0074 | | | | WIND DESIGN: FACTORY MUTUAL PRESSURES OK! | | | | BUILDING APPROVED WITH EXCEPTION! | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | 1A) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 1B) 2ND REQUEST. 2010 FBC-B 1609.1.2 PROTECTION OF | | OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | THAT WILL REQUIRE PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-04-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-04-26 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-04-26 |
Time |
12:08 |
Sent To |
|
|
Notes |
2013-04-26 12:15:15 | BUILDING PLAN REVIEW | | PERMIT:13020210 | | ADD: 701 S ROSEMARY AVE. SUITE # NOT PROVIDED | | CONT: LAKEVIEW CONSTRUCTION | | TEL: (561)635-6935 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | CITY PLACE MANAGEMENT | | CARLOS BERNEL | | 561-820-0074 | | | | 2ND REVIEW | | DATE: 04/26/2013 | | ACTION: DENIED | | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. NO | | TRANSMITTAL LETTER WAS SUBMITTED | | FOR BUILDINGS FIRST ROUND OF COMMENTS. | | | | ADDRESS: THIS PERMIT HAS NOT BEEN PROVIDED WITH THE | | TENANT SUITE NUMBER. ON THE PERMIT APPLICATION AS WELL | | AS PLANS H & M'S OWN STORE NUMBER US 316 HAS BEEN | | MISTAKEN AS THE SUITE NUMBER. PLEASE CORRECT THE PERMIT | | APPLICATION AND PLANS AND PROVIDE THE TENANT SUITE | | NUMBER. | | | | 1) 2ND REQUEST. THE COVER SHEET INDICATES ALL | | STOREFRONT TO BE FILED UNDER SEPERATE PERMIT. PLEASE | | REMOVE THE MENTION OF STOREFRONT FROM THESE PLANS SINCE | | IT IS NOT PART OF THIS PERMIT. TODATE NO SUCH PERMIT | | HAS BEEN APPLIED FOR. | | 2010 WPB ADMINISTRATIVE CODE 107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED... EXAMPLES ARE A200.00 | | NOTE # 1 & A-600.00 ELEVATIONS. | | | | 2) 2ND REQUEST. SHEET A-200.00 THE TENANT SEPERATION | | WALLS: | | 2A) SHEETS 700.00 - 703.00 PROVIDE THE WALL TYPES THAT | | WERE IDENTIFIIED ON A-200.00. A COMMON NOTE ON WALL | | SECTION TYPES ALIGN STUD KNOCK OUTS. ARE THESE DETAILS | | INDICATING NEW WALLS NEXT TO THE EXISTING TENANT | | SEPERATION WALLS WHERE THE STUD KNOK OUTS CAN BE | | ALIGNED OR IS THE 5/8 INCH FIRE RATED DRYWALL BEING | | REMOVED TO PUNCH NEW HOLES IN WHERE THEY DO NOT ALIGN? | | 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. | | | | 2B) THE WALL TAGS FOR THE TENAT SEPERATION WALLS ARE TO | | BE 1 HOUR PER 2010 FBC-B 709.6.1. ON THE SHEETS 700.00- | | 702.00 THEY DO NOT INDICATE THEY ARE ONE HOUR FIRE | | RATED. WALL TYPES L & P ARE INDICATED AS ONE HOUR | | WALLS, WHY ARE THE OTHER WALL TAGS FOUND ON THE TENANT | | SEPERATION DESIGNATED AS ONE HOUR? | | | | 2C) VARIOUS WALLS INDICATE BEING FURRED OUT WITH FIRE | | RETARDANT TREATED 3/4 INCH PLYWOOD, PLEASE PROVIDE | | COMPLIANCE WITH 2010 FBC-B 803.11.1 PLEASE PROVIDE | | WHICH OF THE THREE OPTIONS WILL BE INSTALLED AT THE | | SITE. | | | | 3) 2ND REQUEST. SHEET S010.00 DO PROVIDE THE WIND | | DESIGN CRITERIA IF THE WINDOWS ARE TO BE PART OF THIS | | PERMIT. IF THE WINDOWS ARE TO BE INSTALLED AS PART OF | | THIS PERMIT THEN THE PRESSURES WILL NEED TO BE PROVIDED | | FOR THESE OPENINGS AND TTHE HEIGHT FACTOR FOR A THREE | | STORY BUILDING. | | THE PLANS INDICATE THE BUILDING TO BE 15 FEET TALL WITH | | ASSOCIATED PRESSURES. 2010 FBC-B TABLE 1609.7(2). | | | | 4) 2ND REQUEST. 2010 FBC 107.3.4.1 PRODUCT APPROVALS. | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 5) 2ND REQUEST. 2010 FBC-B 1609.1.2 PROTECTION OF | | OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | THAT WILL REQUIRE PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (G) PRE-ENGINEERED A/C STANDS | | | | 6) COMPLIED. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-02-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-02-28 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-02-28 |
Time |
08:05 |
Sent To |
|
|
Notes |
2013-02-28 11:24:47 | BUILDING PLAN REVIEW | | PERMIT:13020210 | | ADD: 701 S ROSEMARY AVE. SUITE # 316 | | CONT: LAKEVIEW CONSTRUCTION | | TEL: (561)635-6935 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: 02/28/2013 | | ACTION: DENIED | | | | 1) THE COVER SHEET INDICATES ALL STOREFRONT TO BE FILED | | UNDER SEPERATE PERMIT. PLEASE REMOVE THE MENTION OF | | STOREFRONT FROM THESE PLANS SINCE IT IS NOT PART OF | | THIS PERMIT. | | 2010 WPB ADMINISTRATIVE CODE 107.2.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED... EXAMPLES ARE A200.00 | | NOTE # 1 & A-600.00 ELEVATIONS. | | | | 2) SHEET A-200.00 THE TENANT SEPERATION WALLS: | | 2A) SHEETS 700.00 - 703.00 PROVIDE THE WALL TYPES THAT | | WERE IDENTIFIIED ON A-200.00. A COMMON NOTE ON WALL | | SECTION TYPES ALIGN STUD KNOCK OUTS. ARE THESE DETAILS | | INDICATING NEW WALLS NEXT TO THE EXISTING TENANT | | SEPERATION WALLS WHERE THE STUD KNOK OUTS CAN BE | | ALIGNED OR IS THE 5/8 INCH FIRE RATED DRYWALL BEING | | REMOVED TO PUNCH NEW HOLES IN WHERE THEY DO NOT ALIGN? | | 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. | | | | 2B) THE WALL TAGS FOR THE TENAT SEPERATION WALLS ARE TO | | BE 1 HOUR PER 2010 FBC-B 709.6.1. ON THE SHEETS 700.00- | | 702.00 THEY DO NOT INDICATE THEY ARE ONE HOUR FIRE | | RATED. WALL TYPES L & P ARE INDICATED AS ONE HOUR | | WALLS, WHY ARE THE OTHER WALL TAGS FOUND ON THE TENANT | | SEPERATION DESIGNATED AS ONE HOUR? | | | | 2C) VARIOUS WALLS INDICATE BEING FURRED OUT WITH FIRE | | RETARDANT TREATED 3/4 INCH PLYWOOD, PLEASE PROVIDE | | COMPLIANCE WITH 2010 FBC-B 803.11.1 PLEASE PROVIDE | | WHICH OF THE THREE OPTIONS WILL BE INSTALLED AT THE | | SITE. | | | | 3) SHEET S010.00 DO PROVIDE THE WIND DESIGN CRITERIA IF | | THE WINDOWS ARE TO BE PART OF THIS PERMIT. IF THE | | WINDOWS ARE TO BE INSTALLED AS PART OF THIS PERMIT THEN | | THE PRESSURES WILL NEED TO BE PROVIDED FOR THESE | | OPENINGS AND TTHE HEIGHT FACTOR FOR A THREE STORY | | BUILDING. 2010 FBC-B TABLE 1609.7(2). | | | | 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 5) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | WILL REQUIRE PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS. | | (B) WINDOWS | | (G) PRE-ENGINEERED A/C STANDS | | | | 6) SHEET SHEET S110.00 IS FOR BAR JOIST ROOF FRAMING | | AND DETAILS FOR TYPICAL ROOFTOP MECHANICAL UNITS AND | | OPENINGS THAT ARE NEW AND BEING CUT INTO THE ROOF DECK. | | WHY IS THIS SHEET INCLUDED IN THESE PLANS, THERE IS TWO | | STORIES OF R-2 AND BUSINESS OCCUPANCIES BETWEEN THE | | FIRST FLOOR AND THE ROOF? IF ADDITIONAL AC UNITS ARE TO | | BE ADDED THEY WOULD PROBABBLY BE SPLIT UNITS WITH THE | | CONDENSORS ON THE ROOF. IN THAT CASE THE PRE-ENGINEERED | | A/C STANDS WOULD NEED PRODUCT APPROVALS FOR THE WIND | | SPEED AND EXPOSURE CATEGORY PLUS THE DETAILS FOR | | FASTENING OF THE UNIT TO THE ROOF DECK AND OR BAR | | JOIST. PLEASE BE AWARE OF 1609.8 ROOF TOP STRUCTURES | | AND EQUIPMENT. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2013-05-03 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2013-05-03 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2013-05-03 |
Time |
16:20 |
Sent To |
|
|
Notes |
2013-05-03 16:20:49 | ALL CORECTIONS HAVE BEEN MADE..... |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-03-07 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2013-03-07 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2013-03-06 |
Time |
14:41 |
Sent To |
|
|
Notes |
2013-03-07 13:59:07 | 13020210 | | 701 S. ROSEMARY AVENUE #316 | | H&M BUILDING RENOVATION | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | REVIEW COMMENTS. | | | | INDICATE THE FAULT CURRENT CAPACITY REQUIRED FOR THE | | ELECTRICAL SERVICE AND SWITCH GEAR. NEC 110.9, 110.10 | | | | PROVIDE A SAFETY LABELING SCHEDULE ON THE PLAN FOR | | FLASH PROTECTION, HIGH-LEG MARKING, PANEL BOARDS AND | | THE MAIN DISCONNECTING MEANS. NEC 110.22, 110.16, | | 110.22 | | | | PROVIDE A LIGHTING DENSITY SUMMARY ON THE PLANS SHOWING | | COMPLIANCE WITH THE FLORIDA BUILDING ENERGY CODE | | REQUIREMENTS. FBC ENERGY CONSERVATION T505.3 | | | | INDICATE THE APPROPRIATE SIZE FOR THE PULL BOX INTENDED | | TO HOUSE THE MAIN FEEDER CONDUCTORS TO THE MDP. NEC | | 314.28 | | | | NOTE: | | SEPARATE PERMITS ARE REQUIRED FOR LOW VOLTAGE SYSTEMS, | | AUDIO , SECURITY, FIRE ALARM, DATA, POS, ETC. | | | | ROBERT LECKY | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6718 | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2013-05-22 |
|
|
Cont ID |
|
Sent By |
WJOLIN |
Date |
2013-05-22 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-05-22 |
Time |
11:17 |
Sent To |
|
|
Notes |
2013-05-22 11:31:34 | 701 SOUTH ROSEMARY AVENUE - SUITE #151 | | PERMIT #13020210 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | H&M WILL BE RESPONSIBLE FOR ESTABLISHING AND | | IMPLEMENTING WRITTEN PROCEDURES FOR MAINTAINING 36" | | WIDE UNOBSTRUCTED EGRESS AISLES AT ALL TIMES. A COPY OF | | THIS WRITTEN PROCEDURE SHALL BE PROVIDED TO THE FIRE | | INSPECTOR PRIOR TO ISSUANCE OF A CERTIFICATE OF | | OCCUPANCY. IF FIRE INSPECTORS OBSERVE THAT THESE | | PROCEDURES ARE NOT BEING FOLLOWED, THE TENANT WILL BE | | REQUIRED TO PROVIDE FLOOR MARKINGS, BOLLARDS, OR | | DIFFERENT FLOORING MATERIAL SO EGRESS AISLES WILL | | ALWAYS BE READILY IDENTIFIABLE NO MATTER HOW THE | | MERCHANDISE AND DISPLAYS CHANGE. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2013-04-22 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-04-22 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-04-22 |
Time |
13:32 |
Sent To |
|
|
Notes |
2013-04-22 14:10:50 | 701 SOUTH ROSEMARY AVENUE - SUITE #316 | | PERMIT #13020210 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | RESPONSE COMMENT: RELIANCE ON THE TENANT TO MAINTAIN | | CLEAR AISLES HAS NOT BEEN SUCCESSFUL. PLEASE PROVIDE | | FLOOR MARKINGS, BOLLARDS, OR DIFFERENT FLOORING | | MATERIAL SO EGRESS AISLES WILL ALWAYS BE READILY | | IDENTIFIABLE NO MATTER HOW THE MERCHANDISE AND DISPLAYS | | CHANGE. | | ORIGINAL COMMENT: SHEET A-100: PLANS STATE THAT A CLEAR | | WIDTH OF 3'-0" AND 3'-8" IS TO BE MAINTAINED FOR | | EXITING; PLEASE INDICATE HOW THIS WILL BE ACCOMPLISHED | | AND MAINTAINED. | | | | RESPONSE COMMENT: THE FIRE PROTECTION INFORMATION FROM | | THE ORIGINAL COMMENT NEEDS TO BE SUBMITTED EVEN IF THE | | DESIGN IS A PERFORMANCE SPECIFICATION. FOR ISSUANCE OF | | A GENERAL BUILDING PERMIT, SECTION 105.3.1.2(2) OF THE | | FLORIDA BUILDING CODE REQUIRES SEALED FIRE PROTECTION | | CONSTRUCTION DOCUMENTS FOR THE DESIGN OR ALTERATION OF | | 50 OR MORE AUTOMATIC FIRE SPRINKLERS. AFTER THE | | BUILDING PERMIT HAS BEEN ISSUED, THE SPRINKLER | | CONTRACTOR CAN THEN SUBMIT SHOP DRAWINGS (CONFORMING TO | | THE ENGINEERED CONSTRUCTION DOCUMENTS) FOR A | | SUB-PERMIT. | | ORIGINAL COMMENT: SHEET FP-210: PER FLORIDA | | ADMINISTRATIVE CODE SECTION 61G15-32.004, FIRE | | PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | PRE-ENGINEERED SYSTEMS. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2013-02-25 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-02-25 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-02-25 |
Time |
10:29 |
Sent To |
|
|
Notes |
2013-02-25 11:12:03 | 701 SOUTH ROSEMARY AVENUE - SUITE #316 | | PERMIT #13020210 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | NO ADDRESS OR SUITE NUMBERS PROVIDED IN THE PLAN | | TITLEBLOCK INFORMATION. | | | | UPDATE THE CODE LIST TO REFERENCE THE 2010 EDITION OF | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | AMENDMENTS. | | | | ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO | | THE REQUIREMENTS OF NFPA 241. SMOKING SHALL BE | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | BE SUBMITTED IN WRITING (FAX: 561-804-4774) AND | | APPROVED BY THE OFFICE OF THE FIRE MARSHAL LOCATED AT | | 500 NORTH DIXIE HIGHWAY. | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | WWW.KNOXBOX.COM. | | | | SHEET A-100: PLANS STATE THAT A CLEAR WIDTH OF 3'-0" | | AND 3'-8" IS TO BE MAINTAINED FOR EXITING; PLEASE | | INDICATE HOW THIS WILL BE ACCOMPLISHED AND MAINTAINED. | | | | SHEET A-800: THUMB-TURN STYLE DOOR LOCKS TO BE EQUIPPED | | WITH A LOCK/UNLOCK INDICATOR. | | | | SHEET FP-210: PER FLORIDA ADMINISTRATIVE CODE SECTION | | 61G15-32.004, FIRE PROTECTION ENGINEERING DOCUMENTS | | SHALL INCLUDE THE POINT OF SERVICE FOR THE WATER | | SUPPLY, A LIST OF APPLICABLE NFPA STANDARDS APPLICABLE | | TO THE PROJECT, CLASSIFICATION OF HAZARD OCCUPANCY FOR | | EACH ROOM OR AREA, SUPPRESSION SYSTEM TYPE, DESIGN | | DENSITIES, WATER SUPPLY DATA (FIRE PUMP DATA, HYDRANT | | FLOW TEST DATA) AND ANY PERFORMANCE BASED INFORMATION | | SUCH AS PRE-ENGINEERED SYSTEMS. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2013-05-31 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2013-05-30 |
Time |
17:04 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2013-05-20 |
Time |
13:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-05-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-05-03 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-04-09 |
Time |
17:04 |
Sent To |
|
|
Notes |
2013-04-11 17:05:14 | SENT TO C5 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-03-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-03-12 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-02-08 |
Time |
14:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2013-05-30 |
|
|
Cont ID |
|
Sent By |
MOSER |
Date |
2013-05-30 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-05-30 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2013-04-24 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-04-24 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-04-23 |
Time |
14:08 |
Sent To |
|
|
Notes |
2013-04-24 11:35:53 | PLANS DENIED | | 1) ROOF TOP UNITS ARE NOT EXISTING. PLEASE WRIGHT ON | | PLANS SUPPLY BY OTHERS. | | 2) REFER TO SECTION 607.1.5 FIRE WALLS FBC (M) 2010 | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2013-03-12 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-03-12 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-03-12 |
Time |
14:24 |
Sent To |
|
|
Notes |
2013-03-12 14:41:28 | ****CORRECTIONS**** | | | | 1. REVISE PLAN TO SHOW HOW DUCTWORK WILL BE ROUTED | | THROUGH TWO STORIES OF EXISTING APARTMENTS TO THE | | PROPOSED NEW RTUS. | | | | 2. REVISE THE CURB DETAIL ON SHEET 301.12 TO SPECIFY | | FASTENERS, FBC MECHANICAL 301.12. | | | | HAROLD MOSER, MECHANICAL PLANS EXAMINER | | 561-805-6732 | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2013-04-18 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-04-18 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-04-18 |
Time |
10:49 |
Sent To |
|
|
Notes |
2013-04-18 11:11:52 | RE-STAMPED | 2013-04-11 16:40:06 | NEW SHEETS SUBMITTED. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2013-02-27 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-02-27 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-02-26 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2013-05-30 |
|
|
Cont ID |
|
Sent By |
ESCHNEID |
Date |
2013-05-30 |
Time |
15:31 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2013-05-30 |
Time |
15:31 |
Sent To |
|
|
Notes |
2013-05-30 15:32:45 | PER THE PLANS, SEPARATE PERMITS WILL BE SUPPLIED FOR: | | | | A. SIGNS | | B. EXTERIOR ARCADE STOREFRONT | | | | SEE PERMIT NO. 13020353 FOR ROOFTOP SIGHT LINES. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2013-04-25 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2013-04-25 |
Time |
09:27 |
Rev Time |
0.75 |
Received By |
eschneid |
Date |
2013-04-24 |
Time |
17:10 |
Sent To |
|
|
Notes |
2013-04-25 09:34:55 | FAILED | | | | 1) REPEAT COMMENT: THERE IS NEW EQUIPMENT BEING | | INSTALLED ON THE ROOF. IN ACCORDANCE WITH THE CITYPLACE | | DRI, ALL ROOFTOP MECHANICAL EQUIPMENT, INCLUDING BUT | | NOT LIMITED TO SUCH ITEMS AS PUBLIC AND PRIVATE UTILITY | | SERVICE CONNECTIONS; HEATING, VENTILATING, AND AIR | | CONDITIONING SYSTEMS; COMMUNICATIONS DEVICES; AND | | RELATED EQUIPMENT, SHALL BE SCREENED FROM PUBLIC VIEW | | THROUGH ANY COMBINATION OF LANDSCAPING, WALLS AND | | EQUIPMENT LOCATION. PLEASE PROVIDE PLANS OR OTHER | | EVIDENCE THAT THE NEW ROOFTOP MECHANICAL EQUIPMENT WILL | | BE SCREENED FROM PUBLIC VIEW. THIS IS REQUIRED EVEN | | THOUGH THE PLANS STATE THAT THE LANDLORD WILL BE | | SUBMITTING SEPARATE PLANS FOR THE ROOFTOP MECHANICAL | | EQUIPMENT. STAFF NEEDS TO VERIFY THAT THE ROOF | | PENETRATIONS, CURBS, ETC. ARE NOT PLACED IN A LOCATION | | THAT WILL CREATE ISSUES FOR THE FUTURE A/C UNITS. | | | | 2) PER THE PLANS, SEPARATE PERMITS WILL BE SUPPLIED | | FOR: | | | | A. SIGNS | | B. STOREFRONT | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2013-03-05 |
|
|
Cont ID |
|
Sent By |
escheide |
Date |
2013-03-05 |
Time |
13:47 |
Rev Time |
1.00 |
Received By |
eschneid |
Date |
2013-03-05 |
Time |
13:47 |
Sent To |
|
|
Notes |
2013-03-05 13:48:05 | FAILED | | | | 1) THERE IS NEW EQUIPMENT BEING INSTALLED ON THE ROOF. | | IN ACCORDANCE WITH THE CITYPLACE DRI, ALL ROOFTOP | | MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO SUCH | | ITEMS AS PUBLIC AND PRIVATE UTILITY SERVICE | | CONNECTIONS; HEATING, VENTILATING, AND AIR CONDITIONING | | SYSTEMS; COMMUNICATIONS DEVICES; AND RELATED EQUIPMENT, | | SHALL BE SCREENED FROM PUBLIC VIEW THROUGH ANY | | COMBINATION OF LANDSCAPING, WALLS AND EQUIPMENT | | LOCATION. PLEASE PROVIDE PLANS OR OTHER EVIDENCE THAT | | THE NEW ROOFTOP MECHANICAL EQUIPMENT WILL BE SCREENED | | FROM PUBLIC VIEW. | | | | 2) SIGNS REQUIRE SEPARATE PERMIT(S). | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | 2/21/13 | 2013-02-26 14:42:37 | 2/26/13 |
|
|