Plan Review Stops For Permit 13010955 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2013-03-16 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-03-16 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-03-16 |
Time |
16:19 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2013-02-23 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-02-23 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-02-23 |
Time |
10:55 |
Sent To |
M |
|
Notes |
2013-02-23 11:18:49 | 477 SOUTH ROSEMARY AVENUE - SUITE #169 | | PERMIT #13010955 | | MASTER #12100295 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | ORIGINAL COMMENT:THE FIRE PROTECTION ENGINEER OF RECORD | | (DINO PAPPAS) ON THE CONSTRUCTION DOCUMENTS (SHEET FP1) | | INDICATES THE SYSTEM SHALL BE DESIGNED FOR ORDINARY | | HAZARD GROUP II. THE SPRINKLER SHOP DRAWINGS INDICATE | | THE SYSTEM IS DESIGNED FOR LIGHT HAZARD. | | RESPONSE COMMENT: THE LETTER FROM MR. PAPPAS (P.E.) IS | | NOT SEALED AND THEREFORE CANNOT BE ACCEPTED AS CHANGING | | THE DESIGN CRITERIA PER FLORIDA STATUTES. ADDITIONALLY, | | FIRE PROTECTION NOTE #3 ON SHEET FP1 CLEARLY STATES, | | "THE SYSTEM SHALL BE DESIGNED FOR ORDINARY HAZARD GROUP | | II." A REVISION TO (SHEET FP1) OF THE ENGINEERING | | CONSTRUCTION DOCUMENTS NEEDS TO BE SUBMITTED | | (SIGNED/SEALED) BY THE ENGINEER. | | | | REPEAT COMMENT: NO WATER SUPPLY INFORMATION INDICATED | | ON THE PLANS. | | | | REPEAT COMMENT: NO HORIZONTAL SIDEWALL SPRINKLER | | INFORMATION PROVIDED IN THE SPRINKLER SCHEDULE. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2013-02-05 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-02-05 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-02-05 |
Time |
08:58 |
Sent To |
M |
|
Notes |
2013-02-05 10:29:16 | 477 SOUTH ROSEMARY AVENUE - SUITE #169 | | PERMIT #13010955 | | MASTER #12100295 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | THE FIRE PROTECTION ENGINEER OF RECORD (DINO PAPPAS) ON | | THE CONSTRUCTION DOCUMENTS (SHEET FP1) INDICATES THE | | SYSTEM SHALL BE DESIGNED FOR ORDINARY HAZARD GROUP II. | | THE SPRINKLER SHOP DRAWINGS INDICATE THE SYSTEM IS | | DESIGNED FOR LIGHT HAZARD. | | | | FOR THE AREAS EXPOSED TO STRUCTURE (NO CEILING) | | INDICATE IF THE SPACE IS OBSTRUCTED CONSTRUCTION OR | | UNOBSTRUCTED CONSTRUCTION AND INDICATE THE MAXIMUM | | SPRINKLER DISTANCE BELOW THE STRUCTURE/ROOF DECK (IF | | OBSTRUCTED CONSTRUCTION). | | | | NO WATER SUPPLY INFORMATION OR HYDRAULIC CALCULATIONS | | SUBMITTED. | | | | NO HORIZONTAL SIDEWALL SPRINKLER INFORMATION PROVIDED | | IN THE SPRINKLER SCHEDULE. | | | | INDICATE THE REASON FOR THE EXPOSED PIPE/DROP NIPPLE IN | | HEAD DETAIL #3. | | | | THE SPRINKLERS IN THE CEILING CLOUDS (8'-6" AFF) ALONG | | COLUMN LINE 8 ARE LOCATED MORE THAN 7'-6" FROM ONE | | EDGE. | | | | WESLEY JOLIN | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2013-03-25 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-03-25 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-03-13 |
Time |
09:17 |
Sent To |
|
|
Notes |
2013-03-13 09:18:00 | SENT TO FIRE BOX.JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-02-27 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-02-27 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-02-22 |
Time |
16:34 |
Sent To |
|
|
Notes |
2013-02-22 16:34:30 | TO FIRE | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-02-06 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-02-06 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-01-31 |
Time |
17:22 |
Sent To |
|
|
Notes |
2013-01-31 17:22:54 | TO FIRE | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2013-03-25 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-03-25 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-03-25 |
Time |
10:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2013-02-27 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-02-27 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-02-27 |
Time |
15:36 |
Sent To |
|
|
Notes |
2013-02-27 15:39:05 | PLANS DENIED | | REFER TO COMMENTS FROM FIRE. | | PLAN REVIEW BY HAROLD MOSER | | 561-805-6732 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2013-02-06 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-02-06 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-02-06 |
Time |
12:58 |
Sent To |
|
|
Notes |
2013-02-06 13:04:23 | PLANS DENIED | | REFER TO NOTES FROM FIRE. | | PLAN REVIEW BY HAROLD MOSER | | 561-805-6732 | | [email protected] |
|
|