Plan Review Details - Permit 13010727
Plan Review Stops For Permit 13010727 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2013-02-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-02-11 |
Time |
07:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-02-11 |
Time |
07:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-02-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-02-07 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-02-07 |
Time |
13:47 |
Sent To |
|
|
Notes |
2013-02-07 13:53:39 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) THE INSTALLATION SCHEDULE THAT WAS SUBMITTED DOES | | NOT PROVIDE ALL OF THE INFORMATION THAT IS REQUIRED TO | | DETERMINE THAT THE INSTALLATION OF THE STORM PANELS | | WILL MEET THE WINDLOAD REQUIREMENTS OF FBCR 301.2.1. | | THE MOUNTING TYPE (SHEET 2, 4 OF THE DRAWINGS), TYPE OF | | SUBSTRATE THAT YOU ARE ANCHORING TO, TYPE OF ANCHORS | | YOU WILL USE, ANCHOR SPACING, GLASS SEPARATION, EDGE | | DISTANCE, SHUTTER SPAN ARE NEEDED. READ THE PRODUCT | | APPROVAL DRAWINGS TO SEE WHAT WILL WORK FOR YOUR | | SITUATION AND SUPPLY THAT INFORMATION IN THE SCHEDULE. | | THE FOLLOWING IS A LINK TO THE SAMPLE INSTALLATION | | SCHEDULE ON THE CONSTRUCTION SERVICES WEBSITE THAT YOU | | CAN PRINT OUT AND USE: | | HTTP://WPB.ORG/DEVELOPMENT/CONSTRUCTION/PDF/SCHEDULE_FO | | R_INSTALLATION.PDF | | | | 2) THE WORK DESCRIPTION ON THE APPLICATION SPECIFIES | | SHUTTERS ON 20 OPENINGS AND THE SCHEDULE THAT WAS | | SUBMITTED HAS 20 OPENINGS ON THE MAIN HOUSE AND 11 ON | | THE GUEST HOUSE. THE VALUE FOR INSTALLING THE STORM | | PANELS IS $1200.00. PLEASE CLARIFY. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-01-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-30 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-30 |
Time |
12:24 |
Sent To |
|
|
Notes |
2013-01-30 12:27:05 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) IN ADDITION TO THE TWO COPIES OF PRODUCT APPROVALS | | THAT WERE SUBMITTED FOR THE STORM SHUTTERS, PLEASE | | SUBMIT TWO COPIES OF A KEY PLAN AND INSTALLATION | | SCHEDULE. FBC R301.2.1.2 AND DCA RULE 9N-3 | | HTTP://WPB.ORG/DEVELOPMENT/CONSTRUCTION/PDF/SCHEDULE_FO | | R_INSTALLATION.PDF | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2013-01-29 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-01-29 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-01-29 |
Time |
10:30 |
Sent To |
|
|
Notes |
2013-01-29 10:31:15 | SENT TO BLDG FM |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2013-02-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-02-11 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-02-08 |
Time |
07:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-02-07 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-02-07 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-02-04 |
Time |
08:50 |
Sent To |
|
|
Notes |
2013-02-05 08:51:03 | INCOMING SENT TO R MCDOUGALS DESK. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-01-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-30 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-29 |
Time |
17:09 |
Sent To |
|
|
Notes |
2013-01-29 17:10:35 | GAVE TO ROBBIE |
|
|
|