Plan Review Details - Permit 13010310
Plan Review Stops For Permit 13010310 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2013-02-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-02-13 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-02-13 |
Time |
11:32 |
Sent To |
|
|
Notes |
2013-02-13 11:32:59 | ****PROVISO**** | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. GUARDRAIL TO COMPLY WITH FBC RESIDENTIAL 312, TABLE | | 301.5. | | | | 2. HANDRAIL TO COMPLY WITH FBC RESIDENTIAL 311.7.7, | | TABLE 301.5. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-02-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-02-11 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-02-11 |
Time |
17:32 |
Sent To |
|
|
Notes |
2013-02-11 17:34:36 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. OK | | | | 2. PROVIDE THE FLORIDA STATE PRODUCT APPROVAL COVER | | SHEET FOR THE DOOR, FAC 9N-3. WWW.FLORIDBUILDING.ORG | | | | 2ND REVIEW, NOT PROVIDED. A RESPONSE THAT THIS IS | | EXISTING WITH A LABEL WAS GIVEN, BUT A CURRENT PRODUCT | | APPROVAL IS REQUIRED. EVALUATION REPORT WAS PROVIDED | | FIRST REVIEW, BUT NOT THE COVER SHEET. | | | | 3. OK | | | | 4. OK | | | | 5. THE PRODUCT APPROVAL FOR THE SHUTTERS IS A 2007 | | APPROVAL; 2010 REQUIRED FAC9N-3. | | | | 2ND REVIEW, 2010 PRODUCT APPROVAL PROVIDED, BUT THE | | SHEETS WHICH GIVE THE INSTALLATION INSTRUCTIONS (AND | | ANCHOR SPACING) WERE NOT PROVIDED. PLEASE SUBMIT. | | | | 6. PROVIDE A DETAIL FOR THE HANDRAIL FBC RESIDENTIAL | | 311.7.7. | | | | 2ND REVIEW, A RAILING DETAIL WAS PROVIDED; IS THE | | APPLICATION INCORRECT, AND A RAILING TO BE REEPAIRED, | | NOT A HANDRAIL? | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-01-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-01-29 |
Time |
18:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-01-29 |
Time |
18:27 |
Sent To |
E |
|
Notes |
2013-01-29 18:33:26 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. FOR THE SHUTTERS, COMPLETE THE SAMPLE INSTALLATION | | SCHEDULE OR PROVIDE ALL INFORMATION TO SHOW CODE | | COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC R301, | | FBC1609. TWO SETS REQUIRED. THIS FORM IS AVAILABLE IN | | THE LOBBY OR ON THE INTERNET AT | | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | 2. PROVIDE THE FLORIDA STATE PRODUCT APPROVAL COVER | | SHEET FOR THE DOOR, FAC 9N-3. WWW.FLORIDBUILDING.ORG | | | | 3. PROVIDE PRODUCT APPROVAL FOR THE HARDIBOARD SIDING, | | FAC9N-3. | | | | 4. VALUE IS TO INCLUDE VALUE OF ALL LABOR AND | | MATERIALS, FBC 107. PLEASE PROVIDE COST BREAKDOWN AND | | SQUARE FOOT AREA OF ALL ITEMS. | | | | 5. THE PRODUCT APPROVAL FOR THE SHUTTERS IS A 2007 | | APPROVAL; 2010 REQUIRED FAC9N-3. | | | | 6. PROVIDE A DETAIL FOR THE HANDRAIL FBC RESIDENTIAL | | 311.7.7. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2013-02-01 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2013-02-01 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2013-02-01 |
Time |
09:02 |
Sent To |
|
|
Notes |
2013-02-01 09:05:12 | REQUIRES A SEPERATE PERMIT TO ADD SMOKE DETECTORS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-02-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-02-11 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-02-04 |
Time |
08:46 |
Sent To |
|
|
Notes |
2013-02-05 08:47:32 | INCOMING SENT TO S.H. DESK. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-02-01 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2013-02-01 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2013-01-14 |
Time |
11:39 |
Sent To |
|
|
Notes |
2013-01-29 18:33:50 | 1/29 TO ELEC | 2013-01-14 11:39:44 | MISC 1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |