Plan Review Details - Permit 13010303
Plan Review Stops For Permit 13010303
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-01-24 Cont ID  
Sent By rmcdouga Date 2013-01-24 Time 08:03 Rev Time 0.00
Received By rmcdouga Date 2013-01-24 Time 07:02 Sent To  
Notes
2013-03-29 08:29:37ROOFING PRODUCT APPROVAL SUBMITTED FOR CEDAR SHAKES &
 SHINGLES NOA NO. 07-1120.13.
 THE PRODUCT APPROVALS FOR THE BUILT- UP ROOFING WERE
 NOT SUBMITTED AND WILL BE A REVISION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-01-17 Cont ID  
Sent By rmcdouga Date 2013-01-17 Time 10:53 Rev Time 0.00
Received By rmcdouga Date 2013-01-17 Time 06:40 Sent To  
Notes
2013-01-17 10:35:342010 FBC
  
 DENIED BY BUILDING
  
 1) THE APPRAISAL FOR THE IMPROVEMENTS TO THE SUBJECT
 PROPERTY INDICATES THAT THE HOME IS VALUED AT
 $200,000.00. THE 2010 FBC ENERGY CONSERVATION SECTION
 101.4.3, REQUIRES THE PORTIONS OF EXISTING BUILDINGS
 BEING RENOVATED TO COMPLY WITH TABLE 101.4.1 AS IT
 RELATES TO NEW CONSTRUCTION IF THE ESTIMATED COSTS
 EXCEEDS 30 PERCENT OF THE ASSESSED VALUE OF THE
 STRUCTURE. BECAUSE THE VALUE OF THE PROPOSED WORK ($
 65,000.00) EXCEEDS 30 PERCENT OF $200,000.00 ($
 60,000.00), THE WINDOWS, DOORS AND EXTERIOR INSULATION
 ( COMPONENTS BEING CHANGED) ARE REQUIRED TO COMPLY WITH
 SECTION 402.1 AND THE VALUES LISTED IN TABLE 402.1.1 OR
 COMPLY WITH PERFORMANCE-BASE METHOD FOR THE WHOLE HOUSE
 IN SECTION 405. SHOW COMPLIANCE.
  
 2) THE ENGINEER THAT SIGNED AND SEALED THE DESIGN
 PRESSURES FOR THE WINDOW AND DOOR OPENINGS FOR ROYAL
 PALM ALUMINUM IS DIFFERENT THAN THE DESIGNER OF RECORD
 FOR THE PROJECT. THEIR MAXIMUM DESIGN PRESSURES ARE
 ALSO HIGHER THAN THOSE SPECIFIED ON THE PLAN BY THE
 DESIGNER OF RECORD. THE ENGINEER IN RESPONSIBLE CHARGE
 IS REQUIRED TO REVIEW THE SPECIALTY ENGINEER'S WORK AND
 APPROVE IT WITH HIS SHOP DRAWING STAMP. FS 471
  
 3) THE PRODUCT APPROVALS REQUIRED BY DCA RULE 9N-3
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PER CITY AMENDMENTS 107.3.4.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-01-16 Cont ID  
Sent By rlecky Date 2013-01-16 Time 14:43 Rev Time 0.00
Received By rlecky Date 2013-01-16 Time 14:35 Sent To  
Notes
2013-01-16 14:49:49FOR AUDIT PURPOSES ONLY. PLAN REVIEW AND APPROVAL DONE
 BY TEW & TAYLOR PURSANT TO SECTION 553.791(2) F.S.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-01-18 Cont ID  
Sent By mdekle Date 2013-01-18 Time   Rev Time 0.00
Received By mdekle Date 2013-01-14 Time 16:10 Sent To  
Notes
2013-01-16 10:30:01EXPEDITED
 R--1

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2013-01-17 Cont ID  
Sent By rmcdouga Date 2013-01-17 Time 07:39 Rev Time 0.00
Received By rmcdouga Date 2013-01-17 Time 07:39 Sent To  
Notes
2013-01-17 07:40:23NO HVAC PLANS WERE SUBMITTED.

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-01-17 Cont ID  
Sent By rmcdouga Date 2013-01-17 Time 07:12 Rev Time 0.00
Received By rmcdouga Date 2013-01-17 Time 06:40 Sent To  
Notes
2013-01-17 07:14:25FOR AUDIT PURPOSES ONLY. REVIEW AND APPROVAL BY TEW &
 TAYLOR UNDER SECTION 553.791 (2) F.S.

Review Stop Z ZONING
Rev No 1 Status P Date 2013-01-17 Cont ID  
Sent By mdekle Date 2013-01-17 Time   Rev Time  
Received By mdekle Date 2013-01-17 Time   Sent To  
Notes
2013-01-17 10:43:021/17/13