Plan Review Details - Permit 13010222
Plan Review Stops For Permit 13010222
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2013-10-28 Cont ID  
Sent By rmcdouga Date 2013-10-28 Time 13:59 Rev Time 0.00
Received By rmcdouga Date 2013-10-28 Time 13:59 Sent To  
Notes
2013-10-28 17:24:37APPROVED WITH EXCEPTION
  
 THE PRODUCT APPROVAL SUBMITTED FOR THE FRENCH DOORS IS
 NOT IMPACT RATED. THE EGRESS DOOR CAN NOT BE SHUTTERED.
 SUBMIT PRODUCT APPROVALS WITH LARGE MISSILE IMPACT
 RATING FOR THE EGRESS DOOR. FOR THE OTHER DOORS SUBMIT
 2 SETS OF PRODUCT APPROVALS FOR STORM PANELS WITH
 INSTALLATION SCHEDULES.
  
 THE PRODUCT APPROVAL FOR THE SANTEFE CLAY BARREL TILE
 ALLOWS TWO ATTACHMENT METHODS WITH ACCEPTABLE
 ATTACHMENT RESISTANCE. THEY ARE MORTAR OR 3M AH-160
 ROOF TILE ADHESIVE. IF THE AH-160 ADHESIVE IS USED
 SUBMIT TWO SETS OF PRODUCT APPROVALS.
  
 CORRECT REDLINED MARK-UPS ON THE PLANS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2013-10-23 Cont ID  
Sent By RMCDOUGA Date 2013-10-23 Time 08:21 Rev Time 0.00
Received By rmcdouga Date 2013-10-23 Time 07:26 Sent To  
Notes
2013-10-23 08:22:53AWAITING REST OF PLANS FROM ZONING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2013-09-12 Cont ID  
Sent By rmcdouga Date 2013-09-12 Time 18:41 Rev Time 0.00
Received By rmcdouga Date 2013-09-10 Time 17:17 Sent To  
Notes
2013-09-12 17:51:042010 FBC
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF THE EVALUATION REPORT FOR THE
 ICYNENE SPRAY FOAM INSULATION. FBCR 316.3
  
 2) THE ROOF PLAN ON SHEET A-3 SPECIFIES A POLYGLASS
 SELF ADHERED ROOF SYSTEM AND A BASE SHEET FASTENING.
 RAS 117 CALCULATIONS FOR A GAF MODIFIED ROOF SYSTEM (
 NOA #09-0224.01 ) WERE SUBMITTED WITHOUT THE PRODUCT
 APPROVALS WHICH ARE REQUIRED BY DCA RULE 9N-3. IF THE
 GAF SYSTEM WILL BE INSTALLED REMOVE THE NOTES FOR THE
 POLYGLASS SYSTEM FROM THE ROOF PLAN AND SUBMIT THE GAF
 PRODUCT APPROVALS WITH THE APPROVED ASSEMBLY IDENTIFIED
 AND THAT HAVE BEEN REVIEWED AND APPROVED BY THE
 DESIGNER OF RECORD.
  
 3) SUBMIT TWO COPIES OF PRODUCT APPROVALS THAT HAVE
 BEEN REVIEWED AND APPROVED BY THE DESIGNER OF RECORD
 FOR THE CEMENT PANEL SIDING, THE TRANSOM WINDOWS (AS
 SHOWN ON THE FLOOR PLANS ON A-1), THE STRUCTURAL WINDOW
 MULLIONS, BARREL TILE ROOFING AND THE FRONT ENTRY DOOR
 AS REQUIRED BY DCA RULE 9N-3 AND CITY AMENDMENT
 107.3.4.1
  
 4) THERE ARE STILL CONFLICTING NOTES ON THE PLANS IN
 REGARDS TO THE CEMENT PANEL SIDING AND STUCCO OVER
 METAL LATH AND PLYWOOD. SEE FRONT ELEVATION ON A-1 AND
 SHEET A-3 AND CLOUDED NOTE ON RIGHT ELEVATION ON SHEET
 A-1. PLEASE CORRECT. CITY AMENDMENT 107.2.1.3
  
 5) PROVIDE STRUCTURAL DETAILS FOR THE PATIO ROOF ABOVE
 THE DOUBLE FRENCH DOORS. SPECIFY ALL CONNECTORS AND
 ATTACHMENTS REQUIRED TO PROVIDE SUPPORT AND A
 CONTINUOUS LOAD PATH. FBCR 301.1 AND 301.2.1
  
 6) SPECIFY THE CONNECTORS THAT WILL BE USED TO TIE ALL
 OF THE PARAPET FRAMING TOGETHER AND PROVIDE A
 CONTINUOUS LOAD PATH.FBCR 301.1 AND 301.2.1
  
 7) SPECIFY THE ATTACHMENT AND CONNECTORS THAT WILL BE
 USED TO ATTACH THE 2 X 4 ROOF RAFTER FRAMING TO THE
 CONTAINERS. FBCR 301.1 AND 301.2.1
  
 8) SHEET A-1 HAS WHITE-OUT CORRECTION FLUID ON THE
 RIGHT ELEVATION DETAIL. WHITE-OUT SHOULD NOT BE USED TO
 MAKE CORRECTIONS TO SIGNED AND SEALED DRAWINGS
 SUBMITTED FOR PUBLIC RECORD. FS 471 AND CITY AMENDMENTS
 107.2.1.4
  
 9) THE DESIGN PRESSURES FOR THE FRONT DOOR ON SHEET A-1
 WERE NOT CORRECTED AND ARE TOO HIGH. FBCR 301.2.1 AND
 TABLE 301.2(2).
  
 10) PROVIDE A DETAIL THAT SPECIFIES THE ATTACHMENT OF
 THE GUARD RAIL AT THE BALCONY TO THE STRUCTURE. FBCR
 301.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-03-26 Cont ID  
Sent By rmcdouga Date 2013-03-26 Time 16:46 Rev Time 0.00
Received By rmcdouga Date 2013-03-26 Time 15:35 Sent To  
Notes
2013-03-26 15:37:062010 FBC
 DENIED BY BUILDING
  
 1) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE
 STRUCTURE. SHOW COMPLIANCE WITH FBC ENERGY CONSERVATION
 SECTION 401.2.
  
 2) THE UPLIFT PRESSURE OF -75 PSF FOR ROOF ZONE 3 IN
 THE TABLE ON SHEET A-1 IS TOO LOW FOR A LOW SLOPE ROOF
 WITH A MEAN ROOF HEIGHT OF 20 FEET IN EXPOSURE C. SEE
 FBCR 301.2.1, TABLES R301.2(2) AND 301.2(3) .
  
 3) THE WINDLOAD PRESSURES ON SHEET A-1 FOR WALL ZONE 5
 (+ 67.3, -90.1 PSF) ARE TOO HIGH. TABLES R301.2(2) AND
 301.2(3) .
  
 4) SUBMIT TWO COPIES OF THE EVALUATION REPORT FOR THE
 ICYNENE SPRAY FOAM INSULATION. FBCR316.3
  
 5) THE NOTE ON A-1 FOR THE BALCONY GUARDRAIL PICKET
 SPACING IS FOR 2XS AT 6" O.C. THIS LEAVES AN OPENING OF
 4-1/2". FBC R312.3 STATES THAT THE OPENINGS SHALL NOT
 ALLOW THE PASSAGE OF A 4 INCH DIAMETER SPHERE.
  
 6) THERE IS A CONFLICT WITH THE STEEL COLUMN
 INFORMATION ON SHEET A-1. THE STEEL COLUMN DETAIL
 SPECIFIES A 3-1/2" X 3-1/2" X 1/4" STEEL COLUMN AND THE
 NOTE ON THE FRONT ELEVATION CALLS OUT A 4" X 4" X 1/2"
 STEEL COLUMN. PLEASE CLARIFY. CITY AMENDMENTS 107.2.1.3
  
 7) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE
 POLYGLASS SELF-ADHERED ROOFING SYSTEM SPECIFIED ON
 SHEET A-3 THAT HAS BEEN REVIEWED AND APPROVED BY THE
 DESIGNER OF RECORD FOR THIS PROJECT. INDICATE THE
 DESIGN PRESSURE OF THE SYSTEM THAT WILL BE INSTALLED
 AND SUBMIT RAS 117 CALCULATIONS FOR THE ENHANCED
 FASTENING REQUIREMENTS AT THE PERIMETER AND CORNER
 AREAS.DCA RULE 9N-3 AND FBCR 903.1
  
 8) SHOW COMPLIANCE WITH FBCR 318.6 FOR REQUIRED GUTTERS
 AND DOWNSPOUTS ON BUILDINGS WITH EAVES WITH LESS THAN 6
 INCH PROJECTIONS.
  
 9) SUBMIT TWO COPIES OF PRODUCT APPROVALS THAT HAVE
 BEEN REVIEWED AN APPROVED BY THE DESIGNER OF RECORD FOR
 THE HARDI-PLANK SIDING, THE ARCHED WINDOWS, THE FIXED
 GLASS WINDOWS, THE STRUCTURAL WINDOWS AND THE COMPOSITE
 DECKING AS REQUIRED BY DCA RULE 9N-3.
  
 10) THERE IS CONFLICTING INFORMATION ON THE PLANS WITH
 REGARD TO THE ROOF PARAPET DESIGN. THE NOTES ON SHEET
 A-1 AND A-3 SPECIFY 5/8" PLYWOOD WITH METAL LATHE AND
 STUCCO. ON THE PARAPET DETAIL ON SHEET A-2, 4' X 8'
 HARDIE CEMENT BOARD PANEL SIDING IS SPECIFIED. PLEASE
 CLARIFY. CITY AMENDMENTS 107.2.1.3
  
 11) PROVIDE SPECIFICATIONS FOR THE PRE-FAB AWNING OR
 APPLY UNDER A SEPARATE PERMIT. R301.1
  
 PLEASE PROVIDE A RESPONSE LETTER INDICATING HOW THE
 REVIEW COMMENTS HAVE BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-01-17 Cont ID  
Sent By rmcdouga Date 2013-01-17 Time 11:39 Rev Time 0.00
Received By rmcdouga Date 2013-01-16 Time 15:00 Sent To  
Notes
2013-01-16 15:16:452010 FBC
  
 DENIED BY BUILDING
  
 1) THE PLANS APPEAR TO SHOW TWO SEPARATE UNITS EACH
 WITH IT'S OWN KITCHEN. FBCR 302.3 REQUIRES ONE HOUR
 FIRE-RESISTANCE BETWEEN THE TWO UNITS. SHOW COMPLIANCE.
  
 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE
 STRUCTURE. SHOW COMPLIANCE WITH FBC ENERGY CONSERVATION
 SECTION 401.2.
  
 3) THE MEAN ROOF HEIGHT FOR THE STRUCTURE IS 20 FEET
 PER THE PLANS. PLEASE INCREASE THE OPENING PRESSURES TO
 CORRESPOND WITH THE 20 FT MRH. FBCR 301.2.1
  
 4) SHOW COMPLIANCE WITH FBC R318.1 FOR TERMITE
 PROTECTION.
  
 5) SUBMIT TWO COPIES OF THE EVALUATION REPORT FOR THE
 ICYNENE SPRAY FOAM INSULATION. FBCR316.3
  
 6) PROVIDE A DETAIL SHOWING HOW THE FLOOR ASSEMBLY
 ABOVE THE COVERED ENTRY WILL BE INSULATED. FBC ENERGY
 CONSERVATION AND CITY AMENDMENTS 107.2.1
  
 7) THE NOA NUMBERS LISTED IN THE WINDOW AND DOOR
 SCHEDULES ON SHEET A-1 DO NOT MATCH THE ONES ON THE
 PRODUCT APPROVALS THAT WERE SUBMITTED. PLEASE CORRECT.
 CITY AMENDMENTS 107.2.1 AND DCA RULE 9N-3
  
 8) SPECIFY HOW THE BASE OF THE 4 X 4 POSTS SUPPORTING
 THE BALCONY WILL BE ANCHORED TO THE CONCRETE
 FOUNDATION. FBCR 301.1
  
 9) SPECIFY HOW THE BALCONY IS ATTACHED TO THE
 STRUCTURE. CITY AMENDMENTS 107.2.1.3
  
 10) THE FRONT ELEVATION ON A-1 SPECIFIES A 6 X 6 POST
 AT THE BALCONY. PLEASE CLARIFY. CITY AMENDMENTS 107.2.1
  
 11) SHOW THAT THE SPIRAL STAIRS COMPLY WITH FBCR
 311.7.9.1.
  
 12) THE TYPICAL FRAME DETAIL ON A-1 APPEARS TO SHOW
 THAT THE END OF THE SHIPPING CONTAINERS WHERE THE DOORS
 HAVE BEEN REMOVED WILL BE FRAMED WITH 2 X 2 X 1/4"
 STEEL. PLEASE CLARIFY. ALSO CLARIFY HOW THESE WILL BE
 WELDED TO THE STRUCTURE AND HOW THE CORRUGATED STEEL
 SKIN WILL BE ATTACHED TO THE FRAMING. PLEASE BE
 SPECIFIC. CITY AMENDMENTS 107.2.1
  
 13) PROVIDE COMPLETE DETAILS OF THE FRAMING AT THE
 WINDOW AND DOOR OPENINGS AT RIGHT AND LEFT ELEVATIONS.
 FBCR 301.1 AND CITY AMENDMENTS 107.2.1
  
 14) INDICATE THE TYPE OF ROOF COVERING THAT WILL BE
 USED AND SUBMIT PRODUCT APPROVALS FOR IT. FBCR 903.1
  
 15) INDICATE HOW THE PLUMBING VENT ROOF PENETRATIONS
 THROUGH THE CORRUGATED STEEL WILL BE FLASHED. FBCR
 903.2
  
 16) SHOW COMPLIANCE WITH FBCR 318.6 FOR REQUIRED
 GUTTERS AND DOWNSPOUTS ON BUILDINGS WITH EAVES WITH
 LESS THAN 6 INCH PROJECTIONS.
  
 17) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE
 HARDI-PLANK SIDING AND THE COMPOSITE DECKING AS
 REQUIRED BY DCA RULE 9N-3.
  
 18) PROVIDE A STRUCTURAL ANALYSIS THAT INDICATES THE
 UPPER STORAGE CONTAINER CAN BE CANTILEVERED AS
 INDICATED ON THE PLANS. CITY AMENDMENTS 107.2.1.3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-10-23 Cont ID  
Sent By rmcdouga Date 2013-10-23 Time 07:53 Rev Time 0.00
Received By rmcdouga Date 2013-10-23 Time 07:53 Sent To  
Notes
2013-10-23 07:54:17SEE RED-LINED PLANS

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-01-15 Cont ID  
Sent By rlecky Date 2013-01-15 Time 08:47 Rev Time 0.00
Received By rlecky Date 2013-01-14 Time 15:39 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 4 Status P Date 2013-10-25 Cont ID  
Sent By FMITNER Date 2013-10-25 Time 15:13 Rev Time 0.00
Received By fmittner Date 2013-10-25 Time 15:13 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 3 Status F Date 2013-08-08 Cont ID  
Sent By fmittner Date 2013-08-08 Time 13:18 Rev Time 0.00
Received By fmittner Date 2013-08-08 Time 13:18 Sent To  
Notes
2013-08-08 13:21:32BACK TO R6
2013-08-08 13:20:39ELEVATIONS STILL SHOW HARDIE BOARD PANELS AND CONFLICT
 BETWEEN AWNING OR BARREL TILE OVERHANG.

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2013-04-04 Cont ID  
Sent By fmittner Date 2013-04-04 Time 09:06 Rev Time 0.00
Received By fmittner Date 2013-04-04 Time 09:06 Sent To  
Notes
2013-04-04 09:07:44REQUIRES COA APPROVAL FROM HPB FOR NEW CONSTRUCTION. FM
 SPOKE TO NICK B. 4/4/13, WAS AWARE, E-MAILED
 APPLICATION.

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2013-01-30 Cont ID  
Sent By fmittner Date 2013-01-30 Time 10:48 Rev Time 0.00
Received By fmittner Date 2013-01-30 Time 10:48 Sent To  
Notes
2013-01-30 10:49:54NEW CONSTRUCTION WITHIN AN HISTORIC DISTRICT REQUIRES
 APPROVAL BY THE HISTORIC PRESERVATION BOARD VIA A
 CERTIFICATE OF APPROPRIATENESS APPLICATION. QUESTIONS
 CONTACT FRIEDERIKE X1457.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2013-10-28 Cont ID  
Sent By rmcdouga Date 2013-10-28 Time 13:58 Rev Time 0.00
Received By rmcdouga Date 2013-10-03 Time 19:01 Sent To  
Notes
2013-10-04 19:01:50R25

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-09-12 Cont ID  
Sent By rmcdouga Date 2013-09-12 Time 18:11 Rev Time 0.00
Received By rmcdouga Date 2013-08-05 Time 09:53 Sent To  
Notes
2013-08-06 09:54:10R06

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-04-05 Cont ID  
Sent By mdekle Date 2013-04-05 Time   Rev Time 0.00
Received By mdekle Date 2013-03-21 Time 10:29 Sent To  
Notes
2013-03-22 10:33:02R--2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-02-02 Cont ID  
Sent By lmartine Date 2013-01-30 Time 11:00 Rev Time 0.00
Received By lmartine Date 2013-01-09 Time 15:56 Sent To  
Notes
2013-01-09 15:56:49R08

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2013-11-01 Cont ID  
Sent By rmcdouga Date 2013-11-01 Time 16:34 Rev Time 0.00
Received By rmcdouga Date 2013-11-01 Time 16:34 Sent To  
Notes
2013-11-01 16:37:06MU-2013-22149

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2013-10-23 Cont ID  
Sent By rmcdouga Date 2013-10-23 Time 06:41 Rev Time 0.00
Received By rmcdouga Date 2013-10-23 Time 06:40 Sent To  
Notes
2013-10-23 06:41:45NEED A COPY OF THE PAID IMPACT FEE RECIEPT.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2013-03-26 Cont ID  
Sent By rmcdouga Date 2013-03-26 Time 16:48 Rev Time 0.00
Received By rmcdouga Date 2013-03-26 Time 16:48 Sent To  
Notes
2013-03-26 16:50:20AN IMPACT FEE REVIEW BY PALM BEACH COUNTY WILL BE
 REQUIRED.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-01-16 Cont ID  
Sent By rmcdouga Date 2013-01-16 Time 13:20 Rev Time 0.00
Received By rmcdouga Date 2013-01-16 Time 13:20 Sent To  
Notes
2013-01-16 13:21:45AN IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2013-09-10 Cont ID  
Sent By rmcdouga Date 2013-09-10 Time 17:15 Rev Time 0.00
Received By rmcdouga Date 2013-09-10 Time 17:15 Sent To  
Notes
2013-09-10 17:16:43A SEPARATE PERMIT, APPLICATION AND REVIEW IS REQUIRED
 FOR A MECHANICAL PERMIT.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2013-03-27 Cont ID  
Sent By rmcdouga Date 2013-03-27 Time 09:34 Rev Time 0.00
Received By rmcdouga Date 2013-03-27 Time 09:34 Sent To  
Notes
2013-03-27 09:35:272010 FBCR MECHANICAL
  
 1) SUBMIT TWO COPIES OF ENERGY CALCULATIONS PER 2010
 FBC / ENERGY 401.2.
  
 2) ALTHOUGH NO MECHANICAL PERMIT WAS APPLIED FOR AT
 THIS TIME, THE PLANS INDICATE TWO MINI-SPLIT A/C
 SYSTEMS. PLEASE SUBMIT TWO SETS OF EQUIPMENTS SIZING
 CALCULATIONS. TWO SETS OF MECHANICAL PLANS WITH
 EQUIPMENT SCHEDULES, SHOWING THE LOCATIONS OF THE AIR
 HANDLERS AND CONDENSING UNITS. OTHERWISE A SEPARATE
 MECHANICAL PERMIT, APPLICATION AND REVIEW OF THIS
 INFORMATION WILL BE REQUIRED. FBCR M1401.3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2013-01-10 Cont ID  
Sent By tgordon Date 2013-01-10 Time 11:04 Rev Time 0.00
Received By tgordon Date 2013-01-10 Time 11:04 Sent To  
Notes
2013-01-10 11:26:37*** NOTE ***
  
 1) SUBMIT ENERGY CALCULATIONS FOR REVIEW, PER 2010
 FBC/ENERGY 401.2.
  
 2) NO MECHANICAL PERMIT APPLIED FOR AT THIS TIME. A
 MECHANICAL PERMIT WILL BE REQUIRED FOR THE BATHROOM
 EXHAUST FANS, PER 2010 FBC/R M1507.
  
 3) PLEASE STATE ON BUILDING PLANS IF THE WALL MOUNTED
 A/C UNITS HAVE PLUGS OR ARE HARD WIRED, AS THEY MAY
 NEED A MECHANICAL PERMIT ALSO, PER 2010 FBC 107.3.5.
  
 MECHANICAL PLAN REVIEW BY:
 TOM GORDON (HY-BYRD INC.) (561) 805-6732
  
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2013-10-23 Cont ID  
Sent By RMCDOUGA Date 2013-10-23 Time 07:26 Rev Time 0.00
Received By rmcdouga Date 2013-10-23 Time 07:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2013-09-10 Cont ID  
Sent By rmcdouga Date 2013-09-10 Time 16:52 Rev Time 0.00
Received By rmcdouga Date 2013-09-10 Time 15:41 Sent To  
Notes
2013-09-10 17:04:152010 FBC
  
 DENIED BY PLUMBING
  
 1) THE FIRST FLOOR SHOWER AND WATER CLOSET ARE NOT
 VENTED. FBCR P3101.2.1, P3105.1 AND P3108
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2013-03-25 Cont ID  
Sent By rmcdouga Date 2013-03-25 Time 10:49 Rev Time 0.00
Received By rmcdouga Date 2013-03-25 Time 09:04 Sent To  
Notes
2013-03-25 11:18:162010 FBC
  
 DENIED BY PLUMBING
  
 1) PLUMBING RISER DIAGRAM DOES NOT MATCH FLOOR PLAN.
 THE DIAGRAM SHOWS A SINK ON THE SECOND FLOOR AND A
 DOUBLE LAVATORY AT THE FIRST FLOOR BATHROOM. PLEASE
 CORRECT.
  
 2) THE BATHROOM GROUP ON THE LOWER FLOOR ARE NOT
 PROPERLY VENTED. THE VERTICAL WET VENT IS ONLY
 PERMITTED TO VENT A COMBINATION OF FIXTURES LOCATED ON
 THE SAME FLOOR LEVEL PER FBCR P3108.4. ALSO SEE P3109.2
 A VERTICAL WASTE STACK VENT CAN NOT RECEIVE THE
 DISCHARGE OF WATER CLOSETS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-01-15 Cont ID  
Sent By rmcdouga Date 2013-01-15 Time 15:07 Rev Time 0.00
Received By rmcdouga Date 2013-01-15 Time 15:07 Sent To  
Notes
2013-01-15 15:59:522010 FBC
  
 DENIED BY PLUMBING
  
 1) PLUMBING RISER DIAGRAM DOES NOT MATCH FLOOR PLAN.
 THE DIAGRAM SHOWS TWO LAVATORIES AND NO KITCHEN SINK ON
 THE LOWER FLOOR. PLEASE CORRECT.
  
 2) THE FIXTURES ON THE LOWER FLOOR ARE NOT VENTED. THE
 VERTICAL WET VENT IS ONLY PERMITTED TO VENT A
 COMBINATION OF FIXTURES LOCATED ON THE SAME FLOOR LEVEL
 PER FBCR P3108.4.
  
 3) THE KITCHEN SINK ON THE UPPER FLOOR CAN NOT TIE INTO
 THE VERTICAL WET VENT FOR THE BATHROOM GROUP. THE WATER
 CLOSET IS REQUIRED TO BE THE LOWEST CONNECTION TO THE
 VERTICAL WET-VENTED SECTION PER FBCR P3108.4.
 THEREFORE, THE HORIZONTAL BRANCH FOR THE KITCHEN SINK
 IS REQUIRED TO CONNECT TO THE VERTICAL DRAIN BELOW THE
 WATER CLOSET.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2013-10-28 Cont ID  
Sent By rmcdouga Date 2013-10-28 Time 18:40 Rev Time 0.00
Received By rmcdouga Date 2013-10-28 Time 18:35 Sent To  
Notes
2013-10-28 18:39:51ROOFING PRODUCT APPROVALS SUBMITTED :
 CLAY TILE NOA NO. 12-0529.12
 POLYGLASS UNDERLAYMENT NOA NO. 12-0713.02
 POLYGLASS SELF-ADHERED ROOF SYSTEM NOA NO. 12-0815.07
 GAF MODIFIED ROOF SYSTEM WITH RAS 117 CALCS. NOA NO.
 09-0224.01

Review Stop Z ZONING
Rev No 4 Status P Date 2013-10-25 Cont ID  
Sent By FMITNER Date 2013-10-25 Time 15:13 Rev Time 0.00
Received By fmittner Date 2013-10-25 Time 15:13 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2013-08-08 Cont ID  
Sent By fmittner Date 2013-08-08 Time 13:17 Rev Time 0.00
Received By fmittner Date 2013-08-08 Time 13:17 Sent To  
Notes
2013-08-08 13:18:23SEE NOTE FROM4/4/13....REQUIRES LANDSCAPE PLAN.

Review Stop Z ZONING
Rev No 2 Status F Date 2013-04-04 Cont ID  
Sent By fmittner Date 2013-04-04 Time 09:08 Rev Time 0.00
Received By fmittner Date 2013-04-04 Time 09:08 Sent To  
Notes
2013-04-04 09:08:28REQUIRES LANDSCAPE PLAN.

Review Stop Z ZONING
Rev No 1 Status F Date 2013-01-30 Cont ID  
Sent By fmitter Date 2013-01-30 Time 10:50 Rev Time 0.00
Received By fmittner Date 2013-01-30 Time 10:50 Sent To  
Notes
2013-01-30 10:51:10ONLY ONE UNIT ALLOWED ON SITE. QUESTIONS CONTACT
 FRIEDERIKE 822-1457.
2013-01-16 09:34:281/15/13