Plan Review Stops For Permit 13010154 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2013-04-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-04-19 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-04-19 |
Time |
08:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2013-04-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-04-01 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-04-01 |
Time |
09:20 |
Sent To |
|
|
Notes |
2013-04-01 09:21:23 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | COMMENTS FROM PREVIOUS LISTS: | | | | 1. FBC 1603.4.1, INCLUDE WIND DESIGN CRITERIA. | | | | NOT ADDRESSED. THIS IS TO BE A MINIMUM OF 150MPH | | EXPOSURE C. | | | | 2. OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-02-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-02-28 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-02-28 |
Time |
10:39 |
Sent To |
|
|
Notes |
2013-02-28 10:45:37 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | COMMENTS FROM PREVIOUS LIST: | | | | 1. FBC 1603.4.1, INCLUDE WIND DESIGN CRITERIA. | | | | NOT ADDRESSED. | | | | 2. FOR THE FOUNDATION, PROVIDE CALCULATION TO SHOW THAT | | THE 12X12 FOOTING IS ADEQUATE FOR THE 6' WALL TO RESIST | | WIND LOADS. | | | | 2ND REVIEW, FOUNDATION SIZE INCREASED AND APPEARS CODE | | COMPLIANT. HOWEVER, THE NEW PLAN DOES NOT INCLUDE THE | | SIGNATURE OF THE INDIVIDUAL TAKING RESPONSIBILITY FOR | | THE DESIGN FBC 107. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-01-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-01-18 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-01-18 |
Time |
16:13 |
Sent To |
|
|
Notes |
2013-01-18 16:15:59 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. FBC 1603.4.1, INCLUDE WIND DESIGN CRITERIA. | | | | 2. FOR THE FOUNDATION, PROVIDE CALCULATION TO SHOW THAT | | THE 12X12 FOOTING IS ADEQUATE FOR THE 6' WALL TO RESIST | | WIND LOADS. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2013-01-22 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-01-22 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-01-22 |
Time |
09:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2013-04-05 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-04-05 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-04-05 |
Time |
10:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2013-02-28 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-02-28 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-02-28 |
Time |
10:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2013-01-08 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-01-08 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-01-08 |
Time |
10:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2013-04-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-04-19 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-04-05 |
Time |
11:29 |
Sent To |
|
|
Notes |
2013-04-08 15:47:59 | 4/8 TO FIRE | 2013-04-05 11:29:33 | SENT TO S HILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2013-04-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-04-01 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-03-19 |
Time |
16:07 |
Sent To |
|
|
Notes |
2013-03-22 19:02:06 | | | | 2013-03-19 16:07:43 | INCOMING SENT TO S HILL DESK. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-02-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-02-28 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-02-28 |
Time |
10:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-01-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-01-22 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-01-08 |
Time |
13:05 |
Sent To |
|
|
Notes |
2013-01-18 16:21:32 | 1/18 TO FIRE | | | 2013-01-09 13:06:19 | SENT TO BUILDING UNDER $5000 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2013-04-05 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-04-05 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-04-05 |
Time |
10:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2013-01-08 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-01-08 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-01-08 |
Time |
10:27 |
Sent To |
|
|
Notes |
|
|