Plan Review Details - Permit 13010045
Plan Review Stops For Permit 13010045
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2013-02-19 Cont ID  
Sent By shill Date 2013-02-19 Time 16:11 Rev Time 0.00
Received By shill Date 2013-02-19 Time 16:11 Sent To  
Notes
2013-02-20 08:55:03****PROVISO****
 ****REVISION REQUIRED PRIOR TO FINAL INSPECTION****
 ****ISSUED AT CONTRACTOR'S RISK****
  
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. ADDRESS FIRE DEPT VIOLATION ISSUES AS A REVISION.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2013-02-07 Cont ID  
Sent By shill Date 2013-02-07 Time 13:29 Rev Time 0.00
Received By shill Date 2013-01-29 Time 10:11 Sent To FIRE
Notes
2013-02-07 14:16:56****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 COMMENTS FROM PREVIOUS LIST:
  
 1. 1ST PORTION OF COMMENT OK (RE: CLEAR OPENING SIZE)
  
 STAIR LOCATIONS NOT SHOWN. IT IS NOT CLEAR WHETHER THE
 OPENINGS WITHIN 10' OF THE STAIRS ARE TO BE FIRE RATED.
 "STAIR" WAS WRITTEN ON THE PLAN WITH NO OTHER
 INFORMATION. PROVIDE A PLAN VIEW AND ELEVATIONS IF
 NECESSARY; ALL INFORMATION REQUIRED IN ORDER TO
 DEMONSTRATE CODE COMPLIANCE.
  
 2ND REVIEW, NOT ADDRESSED. THE PLAN SHOWS STAIRS BUT
 DOES NOT INCLUDE ANY DIMENSIONS TO WINDOWS TO BE
 REPLACED. THE PLAN PROVIDED DOES NOT APPEAR TO
 CORRELATE WITH BUILDING AERIALS. IN A CONVERSATION WITH
 THE CONTRACTOR, "STAIRS" AND "FIRE ESCAPES" WERE BOTH
 DISCUSSED. WHERE THESE ELEMENTS ARE LOCATED, HOW THEY
 AFFECT THE MEANS OF EGRESS, IS NOT CLEAR. FIRE DEPT WAS
 UNABLE TO CONFIRM INTEGRITY OF EXITS. ALSO FIRE DEPT
 PROVIDED INFORMATION THAT TWO SECTIONS OF THE BUILDINGS
 ARE SEPARATED (UNITS ON ONE WING DO NOT HAVE ACCESS TO
 EXITS IN THE OTHER WING), AND THIS IS NOT SHOWN ON THE
 PLAN.
  
 SEE FBC EXISTING BUILDING 101.5. COMPLIANCE METHOD IS
 NOT CLEAR. PRESCRIPTIVE COMPLIANCE (FBC EXISTING
 BUILDING 301.2.2), EITHER LIKE MATERIALS PROVIDED NO
 HAZARD TO LIFE, OR COMPLIANCE WITH REQUIREMENTS FOR NEW
 CONSTRUCTION.
  
 FBC EXISTING BUILDING 602.4, ALL NEW WORK TO COMPLY
 WITH REQUIREMENTS OF FLORIDA BUILDING CODE.
  
 PLEASE ALSO SEE FBC CHAPTER 13, PERFORMANCE COMPLIANCE
 METHODS.
  
 SEE FBC 1022.6 (EXIT ENCLOSURES) AND 1026.6, EXTERIOR
 STAIRS (WHICH REFERS TO 1022.6):
  
 OPENINGS WITHIN SUCH EXTERIOR WALLS SHALL BE PROTECTED
 BY OPENING PROTECTIVES HAVING A FIRE PROTECTION RATING
 OF NOT LESS THAN 3/4 HOUR.
  
 **PLEASE NOTE THAT PROVIDING LIKE MATERIALS IS AN
 OPTION PROVIDED NO HAZARD TO LIFE. ** AN ACCURATE LIFE
 SAFETY PLAN AND ACCURATE ELEVATIONS, WITH DIMENSIONS
 WOULD BE HELPFUL IN ORDER TO DETERMINE HAZARD TO LIFE
 AND WHETHER RATED OPENINGS WOULD BE REQUIRED.
 OTHERWISE, PROVIDE A PLAN WHICH SHOWS ENOUGH
 INFORMATION TO SHOW COMPLIANCE WITH FBC 1022.6.
  
 2. OK.
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-01-16 Cont ID  
Sent By shill Date 2013-01-16 Time 17:47 Rev Time 0.00
Received By shill Date 2013-01-16 Time 17:44 Sent To  
Notes
2013-01-16 17:59:54**INFORMATION MAY BE RESUBMITTED VIA EMAIL**
  
 ****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. REVISE THE FLOOR PLAN TO SHOW EXISTING CONDITIONS
 (TYPE OF WINDOW) AND OPENING SIZE FOR BEDROOMS, FBC
 1029, FBC EXISTING BUILDING 2010 604.1, FBC 1609 AS
 REQUESTED IN PREVIOUS REVIEW. THE CLEAR OPENING CANNOT
 BE REDUCED BY MORE THAN 5%.
  
 REVISE THE FLOOR PLAN TO SHOW INTERIOR WALLS FOR
 BEDROOMS. IT IS NOT CLEAR WHETHER SOME UNITS ARE
 EFFICIENCIES OR ONE BEDROOM UNITS.
  
 STAIR LOCATIONS NOT SHOWN. IT IS NOT CLEAR WHETHER THE
 OPENINGS WITHIN 10' OF THE STAIRS ARE TO BE FIRE RATED.
 "STAIR" WAS WRITTEN ON THE PLAN WITH NO OTHER
 INFORMATION. PROVIDE A PLAN VIEW AND ELEVATIONS IF
 NECESSARY; ALL INFORMATION REQUIRED IN ORDER TO
 DEMONSTRATE CODE COMPLIANCE.
  
 NOT ENOUGH INFORMATION PROVIDED BY CONTRACTOR TO
 DETERMINE CODE COMPLIANCE OR TO PROVIDE A COMPREHENSIVE
 CHECKLIST.
  
 2. PROVIDE BUILDING HEIGHT SO WIND LOAD DESIGN
 PRESSURES CAN BE DETERMINED, FBC 1609.
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-01-04 Cont ID  
Sent By shill Date 2013-01-04 Time 18:07 Rev Time 0.00
Received By shill Date 2013-01-04 Time 18:07 Sent To  
Notes
2013-01-04 18:16:53****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, DOOR
 LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE
 EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE
 FOR BEDROOMS, FBC 1029, FBC EXISTING BUILDING 2010
 604.1, FBC 1609. THE CLEAR OPENING CANNOT BE REDUCED BY
 MORE THAN 5%.
  
 SHOW LOCATION OF STAIRWAYS RELATIVE TO DOORS AND
 WINDOWS.
  
 NOT ENOUGH INFORMATION PROVIDED BY CONTRACTOR TO
 DETERMINE CODE COMPLIANCE OR TO PROVIDE A COMPREHENSIVE
 CHECKLIST.
  
 2. PROVIDE BUILDING HEIGHT SO WIND LOAD DESIGN
 PRESSURES CAN BE DETERMINED, FBC 1609.
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-02-16 Cont ID  
Sent By wjolin Date 2013-02-16 Time 08:43 Rev Time 0.00
Received By wjolin Date 2013-02-16 Time 08:43 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2013-02-19 Cont ID  
Sent By shill Date 2013-02-19 Time 16:12 Rev Time 0.00
Received By shill Date 2013-02-11 Time 10:59 Sent To  
Notes
2013-02-12 12:51:582/12/13 ROUTED LATEST FLOOR PLAN WITH OLD PLANS TO FIRE
 - WILL DO BUILDING REVIEW AFTER FIRE REVIEW
 NEEDS DISCUSSION WITH RB
  
2013-02-11 11:00:06GAVE TO SAMANTHA

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By shill Date 2013-01-18 Time 15:12 Sent To  
Notes
2013-01-18 15:12:32TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-01-16 Cont ID  
Sent By shill Date 2013-01-16 Time 17:59 Rev Time 0.00
Received By shill Date 2013-01-08 Time 09:54 Sent To  
Notes
2013-01-09 09:55:08SENT TO SAMANTHA'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-01-04 Cont ID  
Sent By shill Date 2013-01-04 Time 18:17 Rev Time 0.00
Received By shill Date 2013-01-03 Time 14:10 Sent To  
Notes
2013-01-03 14:11:02SENT TO MISC 1 BOX