Plan Review Stops For Permit 13010044 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2013-02-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-02-14 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-02-13 |
Time |
15:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-01-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-08 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-08 |
Time |
10:38 |
Sent To |
|
|
Notes |
2013-01-08 10:59:48 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) SPECIFY THE DESIGN CRITERIA, WINDSPEED AND EXPOSURE | | CATEGORY ON THE PLANS. FBC R301.2.1 AND CITY AMENDMENTS | | 107.3.5.3 | | | | 2) SPECIFY THE COMPONENT AND CLADDING PRESSURES FOR THE | | NEW EXTERIOR DOORS ON THE PLANS. FBC R301.2.1 | | | | 3) SPECIFY THE SIZES OF THE NEW DOORS ON THE PLANS. FBC | | R301.2.1 AND CITY AMENDMENTS 107.2.1 | | | | 4) PROVIDE STRUCTURAL DETAILS FOR THE NEW DOOR OPENINGS | | ON THE PLANS. IF WOOD FRAME, INCLUDE HEADER SIZE, | | FRAMING & STRAPPING INFORMATION. IF MASONRY | | CONSTRUCTION PROVIDE LINTEL INFORMATION AND STEEL | | REINFORCING DETAILS. CITY AMENDMENTS 107.2.1 AND | | 107.2.1.3 | | | | 5) PROVIDE STRUCTURAL DETAILS FOR THE NEW STAIRS. SHOW | | COMPLIANCE WITH FBCR 311.7.4 FOR TREADS & RISERS, FBCR | | 311.7.7 FOR HANDRAILS AND FBCR 312 FOR GUARDS. | | | | 6) PROVIDE STRUCTURAL DETAILS FOR THE PROPOSED HEADER | | AT THE WALL BESIDE THE STAIRS AND SHOW CONTINUOUS LOAD | | PATH TO FOUNDATION. FBCR 301.1 AND CITY AMENDMENTS | | 107.2.1 | | | | 7) SHOW COMPLIANCE WITH FBCR 314.3.1 FOR REQUIRED SMOKE | | ALARMS. | | | | 8) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | NEW EXTERIOR DOORS ARE FOR INSWING DOORS, HOWEVER, THE | | DOORS SHOWN ON THE PLANS ARE OUTSWING. PLEASE CORRECT. | | DCA RULE 9N-3. | | | | 9) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PER | | CITY AMENDMENTS 107.3.5.3. | | | | 10) THE ARCHITECT'S ORIGINAL SIGNATURE IS REQUIRED ON | | THE PLANS. SIGNATURE STAMPS OR PHOTO COPIED SIGNATURES | | ARE NOT ACCEPTABLE . FS 481 AND FAC 61G1-16.003 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2013-02-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-02-13 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-02-13 |
Time |
15:31 |
Sent To |
|
|
Notes |
2013-02-13 15:31:59 | PLANS WERE REDLINED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-01-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-08 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-08 |
Time |
14:49 |
Sent To |
|
|
Notes |
2013-01-08 15:10:41 | 2010 FBC | | | | DENIED BY ELECTRIC | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | ELECTRICAL REVIEW COMMENTS. | | | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND | | OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS | | APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON | | MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH | | ROOM USED FOR SLEEPING. 2010 FBC R314, 315 | | | | 1) NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | | 2) ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW | | GENERAL PURPOSE OUTLETS. NEC 210.12 | | | | 3) GFCI PROTECTION IS REQUIRED FOR ALL BATHROOM | | RECEPTACLES. NEC 210.8 | | | | 4) A GFCI PROTECTED RECEPTACLE IS REQUIRED AT THE FRONT | | AND REAR OF DWELLING UNITS. NEC 210.52 (E) | | | | 5) THE NEW BATHROOM REQUIRES A DEDICATED 20 AMP BRANCH | | CIRCUIT. NEC 210.11 (C) (3) | | | | 6) A GFCI PROTECTED RECEPTACLE IS REQUIRED OUTSIDE AT | | THE FRONT AND BACK ENTRANCE AREA. NEC 210.70, 230.72 | | | | 7) ADD SWITCHES AND RECEPTACLES AS REQUIRED. NEC 210.52 | | | | 8) AT LEAST ONE WALL SWITCH-CONTROLLED LIGHTING OUTLET | | IS REQUIRED IN EVERY HABITABLE ROOM AND BATHROOM. NEC | | 210.70 (A)(1) | | | | 9) AT LEAST ONE WALL SWITCH-CONTROLLED LIGHTING OUTLET | | IS REQUIRED ON THE EXTERIOR SIDE OF OUTDOOR ENTRANCES | | OR EXISTS WITH GRADE LEVEL ACCESS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2013-01-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-01-11 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-01-11 |
Time |
12:03 |
Sent To |
|
|
Notes |
2013-01-11 12:08:29 | GAVE TO LUIS - FM | 2013-01-11 12:04:32 | DOORS MUST HAVE CLEAR GLASS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-02-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-02-14 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-02-12 |
Time |
10:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2013-01-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-15 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-03 |
Time |
06:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2013-02-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-02-13 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-02-13 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2013-01-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-08 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-08 |
Time |
10:17 |
Sent To |
|
|
Notes |
2013-01-08 10:36:51 | 2010 FBC | | | | DENIED BY MECHANICAL | | | | 1) SHOW COMPLIANCE WITH FBCR 303.3 AND FBCR M1507.1 FOR | | BATHROOM VENTILATION. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2013-02-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-02-13 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-02-13 |
Time |
15:29 |
Sent To |
|
|
Notes |
2013-02-13 15:31:15 | A SEPARATE PERMIT, APPLICATION AND REVIEW IS REQUIRED | | FOR THE PLUMBING PERMIT. NO PLUMBING RISER DIAGRAMS | | WERE SUBMITTED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2013-01-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-08 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-08 |
Time |
10:12 |
Sent To |
|
|
Notes |
2013-01-08 10:16:56 | 2010 FBC | | | | DENIED BY PLUMBING | | | | 1) PROVIDE 2 SETS OF PLUMBING DWV RISER DIAGRAMS FOR | | THE PROPOSED WORK AS REQUIRED BY CITY AMENDMENTS | | 107.3.5.3. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2013-01-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2013-01-11 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2013-01-11 |
Time |
12:04 |
Sent To |
|
|
Notes |
|
|