Plan Review Stops For Permit 12120699 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2014-07-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-07-22 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-07-22 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2014-07-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-07-21 |
Time |
19:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-07-21 |
Time |
17:10 |
Sent To |
|
|
Notes |
2014-07-22 10:00:25 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) HCD NEEDS TO CHOOSE THE PRODUCT APPROVALS THAT WILL | | BE USED FOR MASTER. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2014-06-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-06-30 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-06-30 |
Time |
11:08 |
Sent To |
|
|
Notes |
2014-06-30 11:52:03 | 2010 FBC | | | | TRUSS DRAWINGS ARE DENIED | | | | 1) THE DESIGNER OF RECORD FOR THE STRUCTURE HAS | | INDICATED THAT THE TRUSS LAYOUT AND DRAWINGS FOR THE | | MODEL E HIP OPTION DO NOT MATCH THE STRUCTURAL PLANS. | | THE FRAMING AT THE FRONT PORCH IS DIFFERENT THAN THE | | PLANS. | | | | 2) THE TRUSS DRAWINGS FOR THE MODEL E GABLE OPTION DO | | NOT HAVE THE DESIGNER OF RECORDS SHOP REVIEW STAMP ON | | THEM. THEY WILL NEED TO BE REVIEWED BY THE D.O.R. IT | | APPEARS THAT THE TRUSS LAYOUT AND DRAWINGS FOR THIS | | OPTION DOES NOT MATCH THE STRUCTURAL PLANS. THE TRUSS | | DRAWINGS HAVE A TWO PLY GIRDER (B5) NEAR THE FRONT | | PORCH AND THE STRUCTURAL DRAWING SHOW THE TRUSSES | | BEARING ON THE EXTERIOR WALL. | | | | 3) THE TRUSS LAYOUT PLANS ARE NOT SIGNED AND SEALED BY | | THE TRUSS ENGINEER. FS 471 & FAC 61G-31.003 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2014-03-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-12 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-12 |
Time |
10:39 |
Sent To |
|
|
Notes |
2014-03-12 10:39:48 | 2010 FBC | | | | "MASTER" DENIED BY BUILDING | | | | 1) NEED TRUSS DRAWINGS AND PRODUCT APPROVALS THAT HAVE | | BEEN REVIEWED AND APPROVED BY THE DESIGNER OF RECORD. | | SEE PREVIOUS REVIEW COMMENTS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2014-02-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-19 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-19 |
Time |
14:33 |
Sent To |
|
|
Notes |
2014-02-19 16:56:39 | 2010 FBC / MASTER MODEL "E" | | | | DENIED BY BUILDING | | | | 1) SUBMIT TWO COPIES OF A GENERIC MODEL "E" SITE PLANS | | THAT INCLUDE SURFACE WATER DRAINAGE FOR THE MASTER. | | SITE SPECIFIC SITE PLANS WITH DRAINAGE SHOWN AND | | SURVEYS WILL BE REQUIRED FOR EACH PERMIT APPLIED FOR | | UNDER THE MASTER. FBC R401.3 ( NO SHEET A-0.1 WAS | | SUBMITTED.) | | | | 2) REVISE WIND DESIGN DATA ON SHEET S-2 TO REFERENCE | | THE 2010 FBC AND A WIND SPEED OF 170 MPH VULT EXPOSURE | | C AND CHANGE ALL OTHER REFERENCES FROM THE 2007 | | BUILDING CODE TO THE 2010 FBC. FBC R 301.2.1 | | | | 3) ON SHEET S-2, REVISE NOTE 2, B TO REFERENCE ACI | | 315-08. THE 2008 EDITION IS THE ONE REFERENCED BY THE | | 2010 FBCR OR JUST SPECIFY THE CURRENT EDITION. FBCR | | CHAPTER 43 | | | | 4) SUBMIT TWO SETS OF TRUSS DRAWINGS AND LAYOUTS FOR | | ASCE7-10, 170 MPH AND EXPOSURE C THAT HAVE BEEN SIGNED | | AND SEALED BY THE TRUSS ENGINEER AND REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR THE | | MODEL "E" STRUCTURE HIP AND GABLE ROOF OPTIONS. FBC | | R802.1.6.1 THESE ARE REQUIRED TO BE SUBMITTED AND | | REVIEWED FOR THE MASTER. | | | | 5) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE 8" WIDE | | CAST-CRETE LINTELS. THE FLORIDA COVER SHEET IS OKAY. | | NOA NO. 12020913 FOR THE 8" WIDE LINTELS WAS NOT | | SUBMITTED. THE ONE THAT WAS IS FOR THE 4, 6 AND 12" | | WIDE LINTELS. DCA RULE 9N-3 | | | | 6) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE | | MANUFACTURED SIDING (IE HARDI-BOARD) AND THE STRUCTURAL | | CONNECTORS (IE TRUSS ANCHORS) AS REQUIRED BY DCA RULE | | 9N-3. | | | | 7) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. CITY | | AMENDMENTS 107.3.4.1 | | | | 8) THE PLANS LIST THE CONDITIONED SPACE AS 1096 SQFT | | AND THE ENERGY CALCULATIONS HAVE 1072 SQFT. PLEASE | | CLARIFY WHY THERE IS A DIFFERENCE. CITY AMENDMENTS | | 107.2.1 | | | | 9) THE PLANS SHOW TWO BATHROOMS AND THE BUILDING INPUT | | SUMMARY REPORT HAS ZERO BATHROOMS. PLEASE CALRIFY WHY | | THERE IS A DIFFERENCE. CITY AMENDMENTS 107.2.1 | | | | 10) THE WINDOW SCHEDULE SPECIFIES 24 EH AND 2843 EH | | SINGLE HUNG WINDOWS. WHAT DOES EH MEAN? THE 24 EH | | SINGLE HUNG WINDOW IS SPECIFIED AS THE BEDROOM EGRESS | | WINDOWS. A 24-5 SH WINDOW IS WHICH IS 37" X 56" IS | | REQUIRED TO MEET EGRESS REQUIREMENTS. PLEASE CLARIFY. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-09-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-09-18 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-09-18 |
Time |
12:50 |
Sent To |
|
|
Notes |
2013-09-18 13:56:59 | 2010 FBC / MASTER MODEL "E" | | | | DENIED BY BUILDING | | | | 1) SHEETS A0.1,1.2, 2.1,3.1A,3.1B,4.1,AND 5.1 ARE | | MISSING FROM THE PLAN SETS THAT WERE SUBMITTED. CITY | | AMENDMENTS 107.2.1 | | | | 2) THE PLANS ARE NOT IN THE ORDER SPECIFIED BY THE | | DRAWING INDEX ON THE COVER SHEET. CITY AMENDMENTS | | 107.2.1 | | | | 3) SUBMIT TWO SETS OF MODEL "E" WORSE CASE ENERGY | | CALCULATIONS AND EQUIPMENT SIZING CALCULATIONS FOR THE | | MASTER PER 2010 FBC ENERGY CONSERVATION. SITE SPECIFIC | | ENERGY CALCULATIONS WILL BE REQUIRED FOR EACH PERMIT | | APPLIED FOR UNDER THE MASTER. | | | | 4) SUBMIT TWO COPIES OF A GENERIC MODEL "E" SITE PLANS | | THAT INCLUDE SURFACE WATER DRAINAGE FOR THE MASTER. | | SITE SPECIFIC SITE PLANS WITH DRAINAGE SHOWN AND | | SURVEYS WILL BE REQUIRED FOR EACH PERMIT APPLIED FOR | | UNDER THE MASTER. FBC R401.3 | | | | 5) ON SHEET S-2 THE ALLOWABLE COMPONENT AND CLADDING | | WIND PRESSURES FOR THE WALL ZONES IN THE TABLE HAVE AN | | AREA OF 25 SQFT. THE PRESSURES SPECIFIED ON SHEET S-1 | | ARE INCORRECTLY SPECIFYING THESE PRESSURES FOR OPENINGS | | THAT ARE LESS THAN 25 SQFT. FOR WORSE CASE, SPECIFY THE | | PRESSURES FOR A 10 SQFT AREA IN THE TABLE AND FOR THE | | SMALLER OPENINGS. FBC R301.2.1 | | | | 6) ON SHEET S-2, UNDER CONCRETE NOTE #3, THE 1994 | | EDITION OF ACI 315 IS SPECIFIED. PLEASE CHANGE TO 2008 | | EDITION WHICH IS THE EDITION REFERENCED BY THE 2010 | | FBCR OR JUST CURRENT EDITION. FBCR CHAPTER 43 | | | | 7) SUBMIT TWO SETS OF TRUSS DRAWINGS AND LAYOUTS FOR | | ASCE7-10, 170 MPH AND EXPOSURE C THAT HAVE BEEN SIGNED | | AND SEALED BY THE TRUSS ENGINEER AND REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR THE | | MODEL "E" STRUCTURE. FBC R802.1.6.1 THESE ARE REQUIRED | | TO BE SUBMITTED AND REVIEWED FOR THE MASTER. | | | | 8) TWO COPIES OF PRODUCT APPROVALS ARE REQUIRED FOR | | EACH TYPE OF WINDOW AND DOOR, STRUCTURAL MULLIONS, ROOF | | COVERING, STORM PANELS (IF IMPACT GLAZING IS NOT USED), | | BLOCK LINTELS, MANUFACTURED SIDING (IE HARDI-BOARD), | | STRUCTURAL CONNECTORS (IE TRUSS ANCHORS) AS REQUIRED BY | | DCA RULE 9N-3. NOTE:THE COPIED PRODUCT APPROVALS FROM | | MODEL B THAT WERE SUBMITTED ARE CURRENT & CAN BE USED | | IF THESE ARE THE PRODUCTS THAT WILL BE INSTALLED FOR | | THIS MODEL. | | | | 9) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. CITY | | AMENDMENTS 107.3.4.1 | | | | SEE REVIEW COMMENTS UNDER OTHER TRADES. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2013-01-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-04 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-04 |
Time |
16:42 |
Sent To |
|
|
Notes |
2013-01-04 16:42:43 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) TWO OR MORE SETS OF PLANS THAT HAVE BEEN SIGNED AND | | SEALED BY THE DESIGNER OF RECORD ARE REQUIRED TO BE | | SUBMITTED FOR PERMIT PER CITY AMENDMENTS 107.1. | | | | 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS AS REQUIRED | | BY FBC ENERGY CONSERVATION SECTION 405.4. | | | | 3) UPDATE THE WIND SPEED INFORMATION ON SHEET S-2 TO | | 170 MPH VULT / 132 VASD. FBCR301.2.1 | | | | 4) UPDATE THE CODE AND STANDARDS REFERENCED ON SHEET | | S-2 TO FBC 2010, ACI 318 - 2008, ACI 530 - 2008 AND ACI | | 315 - 2008. FBCR CHAPTER 43 | | | | 5) EXPOSURE CATEGORY C IS SPECIFIED ON THE PLANS. NOTE: | | IF THERE ARE ANY STRUCTURES THAT WILL BE CONSTRUCTED | | UNDER THIS MASTER WITHIN 600 FT OF THE INTER-COASTAL | | WATERWAY OR OTHER BODY OF WATER WITH A ONE MILE FETCH | | THEN THEY ARE CONSIDERED EXPOSURE D. FBCR 301.2.1.4.2 | | | | 6) SUBMIT TWO COPIES OF A SURFACE DRAINAGE PLAN. | | FBCR401.3 | | | | 7) UPDATE CODE AND STANDARDS ON THE COVER SHEET (IE | | 2010 FBC, 2010 FIRE PREVENTION CODE,2008 NEC). NOTE: | | THE FAIRHOUSING GUIDELINES DO NOT APPLY TO ONE AND TWO | | FAMILY DWELLINGS. | | | | 8) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR EXTERIOR | | WINDOWS, DOORS, ROOFING MATERIAL, BLOCK LINTELS, TRUSS | | ANCHORS, ETC. AS REQUIRED BY DCA RULE 9N-3. | | | | 9) PRODUCT APPROVALS ARE REQUIRED TO REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PER CITY | | AMENDMENTS 107.3.4.1. | | | | NOTE: THE ONE SET OF PLANS THAT WAS SUBMITTED WAS | | RED-LINED TO SHOW WHERE CORRECTIONS WERE NEEDED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2014-02-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-19 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-19 |
Time |
14:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2013-09-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-09-18 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-09-18 |
Time |
12:51 |
Sent To |
|
|
Notes |
2013-09-18 14:58:38 | 2008 NEC | | | | DENIED BY ELECTRIC | | | | 1) THE MECHANICAL EQUIPMENT SCHEDULE SPECIFIES THE | | MAXIMUM OVER CURRENT PROTECTION FOR THE CONDENSING UNIT | | TO BE 35 AMPS. THE ELECTRICAL PANEL SCHEDULE SHOWS A 40 | | AMP BREAKER. PLEASE CORRECT. | | | | 2) THE MECHANICAL EQUIPMENT SCHEDULE SPECIFIES THE | | MAXIMUM OVER CURRENT PROTECTION FOR THE AIR AHANDLER | | UNIT TO BE 30 AMPS. THE ELECTRICAL PANEL SCHEDULE SHOWS | | A 45 AMP BREAKER. PLEASE CORRECT. | | | | 3) PROVIDE A 2ND GROUND ROD TO MEET REQUIRED OHM | | RESISTANCE. NEC 250.56 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2013-01-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-03 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-03 |
Time |
09:54 |
Sent To |
|
|
Notes |
2013-01-03 09:56:10 | 2010 FBC | | | | DENIED BY ELECTRIC | | | | 1) ARC-FAULT CIRCUIT-INTERRUPTERS REQUIRED IN | | ACCORDANCE WITH 2008 NEC ARTICLE 210.12. | | | | 2) TAMPER-RESISTANT RECEPTACLES REQUIRED IN ACCORDANCE | | WITH 2008 NEC ARTICLE 210.12. | | | | 3) PLEASE UPDATE THE CODE EDITIONS REFERENCED ON | | ELECTRICAL SHEETS TO 2010 FBC, 2007 NFPA 72, 2009 NFPA | | 101 AND 2010 NFPA 1. | | | | 4) TWO OR MORE SETS OF PLANS THAT HAVE BEEN SIGNED AND | | SEALED BY THE DESIGNER OF RECORD ARE REQUIRED TO BE | | SUBMITTED FOR PERMIT PER CITY AMENDMENTS 107.1. | | | | NOTE: THE ONE SET OF PLANS THAT WAS SUBMITTED WAS | | REDLINED TO SHOW WHERE CORRECTIONS WERE NEEDED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2014-03-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-03-12 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-03-10 |
Time |
10:38 |
Sent To |
|
|
Notes |
2014-03-12 10:39:02 | SENT TO R MCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2014-02-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-19 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-05 |
Time |
14:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2014-02-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-09-24 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-09-03 |
Time |
12:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2013-09-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-09-18 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-09-18 |
Time |
15:53 |
Sent To |
|
|
Notes |
2013-09-18 15:53:50 | NOT REQUIRED FOR MASTER. PLANS SUBMITTED FOR PERMIT | | UNDER THE MASTER ARE REQUIRED TO BE REVIEWED BY PALM | | BEACH COUNTY FOR IMPACT FEES. ONE SET OF APPROVED PLANS | | TO BE TAKEN TO COUNTY AND REVIEWED. THE PLANS WITH THE | | IMPACT FEE STAMP AND A COPY OF THE IMPACT FEE PAID | | RECEIPT ARE TO BE RETURNED TO WPB BUILDING DIVISION FOR | | REVIEW BEFORE THE BUILDING PERMIT CAN BE ISSUED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2014-02-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-19 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-19 |
Time |
14:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2013-09-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-09-18 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-09-18 |
Time |
12:51 |
Sent To |
|
|
Notes |
2013-09-18 14:54:07 | 2010 FBC | | | | DENIED BY MECHANICAL | | | | 1) ON PLAN SHEET M-1. WIND LOAD REFERS TO TABLE 1609.6A | | FBC 2007. THIS TABLE IS NO LONGER IN THE CODE. CHANGE | | TO 2010 FBCR AND ASCE 7-10. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2013-01-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-03 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-03 |
Time |
11:27 |
Sent To |
|
|
Notes |
2013-01-03 11:27:42 | 2010 FBC | | | | DENIED BY MECHANICAL | | | | 1) TWO OR MORE SETS OF PLANS THAT HAVE BEEN SIGNED AND | | SEALED BY THE DESIGNER OF RECORD ARE REQUIRED TO BE | | SUBMITTED FOR PERMIT PER CITY AMENDMENTS 107.1. | | | | 2) SUBMIT TWO SETS OF EQUIPMENT SIZING CALCULATIONS AS | | REQUIRED BY FBCR M1401.3. | | | | 3) SUBMIT TWO SETS OF ENERGY CALCULATIONS AS REQUIRED | | BY FBC ENERGY CONSERVATION SECTION 405.4. | | | | 4) ON SHEET M-1 UPDATE THE WIND SPEED TO 170 MPH | | VULT/132 MPH VASD AND THE EDITION OF ASCE 7 TO ASCE | | 7-10. FBCR 301.2.1 AND CHAPTER 43. | | | | NOTE: THE ONE SET OF PLANS THAT WAS SUBMITTED WAS | | RED-LINED TO SHOW WHERE CORRECTIONS WERE NEEDED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2014-02-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2014-02-19 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2014-02-19 |
Time |
14:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2013-09-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-09-18 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-09-18 |
Time |
12:51 |
Sent To |
|
|
Notes |
2013-09-18 14:59:43 | 2010 FBC | | | | PLUMBING DENIED | | | | 1) REMOVE THE "WITH 2009 SUPPLEMENT" FROM PLUMBING NOTE | | 1 ON SHEET P-2. | | | | 2) CHANGE THE NOTE AT THE BOTTOM OF THE HORIZONTAL PIPE | | SLOPE TABLE ON SHEET P-2 FROM 2007 TO 2010 FBC. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2013-01-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-03 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-03 |
Time |
09:52 |
Sent To |
|
|
Notes |
2013-01-03 09:52:27 | 2010 FBC | | | | DENIED BY PLUMBING | | | | 1) TWO OR MORE SETS OF PLANS THAT HAVE BEEN SIGNED AND | | SEALED BY THE DESIGNER OF RECORD ARE REQUIRED TO BE | | SUBMITTED FOR PERMIT PER CITY AMENDMENTS 107.1. | | | | 2) REVISE PLUMBING NOTE #1 ON SHEET P-2 TO REFERENCE | | THE 2010 FBC. | | | | 3) REVISE THE AIR ADMITTANCE VALVE DETAIL TO REFERENCE | | THE CURRENT CODE SECTIONS (IE FBC PLUMBING 917.4 AND | | FBCR P3114.4). | | | | NOTE: THE ONE SET OF PLANS THAT WAS SUBMITTED WAS | | RED-LINED TO SHOW WHERE CORRECTIONS WERE NEEDED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2013-09-24 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2013-09-24 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2013-09-24 |
Time |
09:02 |
Sent To |
|
|
Notes |
2013-09-24 09:05:02 | PROVISO: MASTER PERMIT FOR STRUCTURE ONLY! EACH | | PROPERTY SHALL BE PERMITTED SEPARATELY AND SHALL | | PROVIDE SITE-SPECIFIC SITE PLANS, LANDSCAPE PLANS, ETC. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL | | PLANNER, AT [email protected] OR (561) 822-1448. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2013-09-19 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2013-09-19 |
Time |
08:25 |
Rev Time |
0.00 |
Received By |
llouie |
Date |
2013-09-19 |
Time |
08:25 |
Sent To |
|
|
Notes |
2013-09-19 08:26:39 | ZONING REVIEW NOT REQUIRED FOR MASTER; HOWEVER, PLEASE | | NOTE THE FOLLOWING: | | | | 1.) A SURVEY SHALL BE REQUIRED FOR EACH SITE SPECIFIC | | PROJECT. | | | | 2.) THE SITE PLAN FOR EACH SITE SPECIFIC PROJECT SHALL | | COMPLY WITH THE CITY?S ZONING AND LAND DEVELOPMENT | | REGULATIONS. | | | | 3.) THE LANDSCAPING FOR EACH SITE SPECIFIC PROJECT | | SHALL REQUIRE A SEPARATE PERMIT AND SHALL BE | | ACCOMPANIED WITH LANDSCAPE AND IRRIGATION PLANS. | | |
|
|