Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-12-27 Cont ID  
Sent By shill Date 2012-12-27 Time 10:31 Rev Time 0.00
Received By shill Date 2012-12-27 Time 10:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-12-21 Cont ID  
Sent By shill Date 2012-12-21 Time 15:15 Rev Time 0.00
Received By shill Date 2012-12-21 Time 15:15 Sent To  
Notes
2012-12-21 15:19:01****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. FASTENING PROPOSED IS FOR ZONE 1 ONLY AS IT HAS A
 LIMITATION OF -60PSF.
  
 PROVIDE FASTENING FOR ZONES 2 AND 3. ENHANCED FASTENING
 TO BE IN ACCORDANCE WITH RAS117 PER GENERAL LIMITATION
 #7 OF THE NOA (LAST PAGE). REQUIRED PRESSURES FOR
 EXPOSURE, 170MPH, 15MRH ARE: ZONE 2 -63.6, ZONE 3
 -95.7.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-12-20 Cont ID  
Sent By shill Date 2012-12-20 Time 10:47 Rev Time 0.00
Received By shill Date 2012-12-20 Time 10:47 Sent To  
Notes
2012-12-20 10:49:46****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. SQUARE FOOT AREA ON APPLICATION (800SF) DOES NOT
 MATCH PAPA RECORDS. PLEASE CLARIFY ROOF AREA PROPOSED
 FOR REROOF.
  
 2. THE ASSSEMBLY ON PAGE 14 IS CIRCLED, BUT DOES NOT
 MATCH THE PROPOSED ENHANCED FASTENING LETTER WHICH
 REFERS TO DESIGN PRESSURE OF -52.5 AND RING SHANK
 NAILS. FASTENING FOR ASSEMBLIES ON SELECTED PAGE USES
 SIMPLEX MEGA CAP NAILS, -45 AND -60PSF.
  