Plan Review Stops For Permit 12120056 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2013-02-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-02-07 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-02-07 |
Time |
11:36 |
Sent To |
|
|
Notes |
2013-02-07 11:36:56 | BUILDING PLAN REVIEW | | PERMIT: 12120056 | | ADD: 4011 BROADWAY | | CONT: ALFONSO CRUZ | | TEL: (561)585-2429 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | FEB. 07/2013 | | ACTION: DENIED | | | | 1) THE PLANS INDICATE CREATING A PASSAGEWAY BETWEEN | | TENANT SPACES. A PERMIT WAS PULLED IN 1990, PERMIT # | | 90A01897 FOR A TAKE OUT RESTARAUNT. IS THIS THE | | EXISTING KITCHEN. PLEASE PROVIDE A COMPLETE PLAN OF THE | | WHOLE OF THE TENANT SPACE WITH THE EXISTING KITCHEN. | | PLEASE ALSO PROVIDE SEATING, TABLES AND CHAIRS FOR THE | | NEW DINING AREA, PROVIDE THE ACTUAL OCCUPANT LOAD USING | | 15 SQUARE FEET PER OCCUPANT. | | | | MISSING INFORMATION FOR THE MINIMUM CRITERIA FOR | | COMMERCIAL PLAN REVIEW: | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE | | EXAMINATION OF THE DOCUMENTS BY THE | | BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM | | CRITERIA AND DOCUMENTS: A FLOOR PLAN; SITE | | PLAN; FOUNDATION PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS | | LAYOUT; ALL FENESTRATION PENETRATIONS; | | FLASHING; AND ROUGH OPENING DIMENSIONS; AND ALL | | EXTERIOR ELEVATIONS: | | 107.3.5.1 COMMERCIAL BUILDINGS: | | 107.3.5.1.1 BUILDING | | 2. OCCUPANCY GROUP 303.1 | | 6. LIFE SAFETY SYSTEMS SHALL BE DETERMINED AND SHALL | | INCLUDE THE FOLLOWING REQUIREMENTS: | | OCCUPANT LOAD AND EGRESS CAPACITIES TABLE 1004.1.1 USE | | 15 SQ FT / 900/ 15= 60 OCCUPANTS A3 OCCUPANCY. | | 7. OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: 60 | | OCCUPANTS X.2 | | OCCUPANCY LOAD60 | | NET | | MEANS OF EGRESS | | EXIT ACCESS | | 8 STRUCTURAL REQUIREMENTS, CUTTING THROUGH A BLOCK | | WALL, LINTEL REQUIRED | | 10 . ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE | | FOLLOWING: | | ACCESSIBLE ROUTE | | TOILET FACILITIES SEE PLUMBING COMMENTS AS TO TWO | | RESTROOMS REQUIRED. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-12-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-12-11 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-12-11 |
Time |
15:50 |
Sent To |
|
|
Notes |
2012-12-11 15:52:50 | BUILDING PLAN REVIEW | | PERMIT: 12120056 | | ADD: 4011 BROADWAY | | CONT: ALFONSO CRUZ | | TEL: (561)585-2429 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DEC. 11/ 2012 | | ACTION: DENIED | | | | 1) THE PLANS INDICATE CREATING A PASSAGEWAY BETWEEN | | TENANT SPACES. A PERMIT WAS PULLED IN 1990, PERMIT # | | 90A01897 FOR A TAKE OUT RESTARAUNT. IS THIS THE | | EXISTING KITCHEN. PLEASE PROVIDE A COMPLETE PLAN OF THE | | WHOLE OF THE TENANT SPACE WITH THE EXISTING KITCHEN. | | PLEASE ALSO PROVIDE SEATING, TABLES AND CHAIRS FOR THE | | NEW DINING AREA, PROVIDE THE ACTUAL OCCUPANT LOAD USING | | 15 SQUARE FEET PER OCCUPANT. | | | | MISSING INFORMATION FOR THE MINIMUM CRITERIA FOR | | COMMERCIAL PLAN REVIEW: | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE | | EXAMINATION OF THE DOCUMENTS BY THE | | BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM | | CRITERIA AND DOCUMENTS: A FLOOR PLAN; SITE | | PLAN; FOUNDATION PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS | | LAYOUT; ALL FENESTRATION PENETRATIONS; | | FLASHING; AND ROUGH OPENING DIMENSIONS; AND ALL | | EXTERIOR ELEVATIONS: | | 107.3.5.1 COMMERCIAL BUILDINGS: | | 107.3.5.1.1 BUILDING | | 2. OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS | | SHALL BE DETERMINED. | | 6. LIFE SAFETY SYSTEMS SHALL BE DETERMINED AND SHALL | | INCLUDE THE FOLLOWING REQUIREMENTS: | | OCCUPANT LOAD AND EGRESS CAPACITIES | | 7. OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | OCCUPANCY LOAD | | NET | | MEANS OF EGRESS | | EXIT ACCESS | | 8 STRUCTURAL REQUIREMENTS, CUTTING THROUGH A BLOCK | | WALL, LINTEL REQUIRED | | 10 . ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE | | FOLLOWING: | | ACCESSIBLE ROUTE | | TOILET FACILITIES SEE PLUMBING COMMENTS AS TO TWO | | RESTROOMS REQUIRED. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2013-02-15 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2013-02-15 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2013-02-15 |
Time |
14:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2012-12-26 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-12-26 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-12-21 |
Time |
15:42 |
Sent To |
|
|
Notes |
2012-12-26 13:58:23 | | | 12120056 | | 4011 BROADWAY | | INTERIOR RENOVATION TO BATHROOM | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | REVIEW COMMENT. | | | | PROVIDE AN ELECTRICAL RISER PLAN SHOWING THE EXISTING | | SERVICE SIZE. SHOW CONDUIT AND FEEDERS TO THE RELOCATED | | PANEL BOARD. INDICATE SIZE OF PANEL BOARD AND LOCATION | | OF MAIN DISCONNECT. NEC 215.5 | | | | | | ROBERT LECKY | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6718 | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2013-02-02 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2013-02-02 |
Time |
20:16 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2013-02-02 |
Time |
19:50 |
Sent To |
|
|
Notes |
2013-02-02 20:15:43 | 4011 BROADWAY | | PERMIT #12120056 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | THE TWO COMBINED DINING AREAS OF 375 SQ.FT. AND 525 | | SQ.FT. RESULT IN AN OCCUPANT LOAD OF 60 PERSONS. THIS | | INCREASE IN OCCUPANT LOAD WILL CHANGE THE OCCUPANCY | | CLASSIFICATION FROM MERCANTILE TO ASSEMBLY. | | | | EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS | | SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A | | CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM. | | SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | ASSEMBLY OCCUPANCIES REQUIRE EMERGENCY LIGHTING. | | EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A MINIMUM | | OF 1-1/2 HOURS IN THE EVENT OF FAILURE OF NORMAL | | LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE | | ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT | | LESS THAN AN AVERAGE OF 1 FT-CANDLE AND, AT ANY POINT, | | NOT LESS THAN 0.1 FT-CANDLE, MEASURED ALONG THE PATH OF | | EGRESS AT FLOOR LEVEL. | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | NO EXIT DOOR INFORMATION PROVIDED. DOORS SHALL BE | | ARRANGED TO BE OPENED READILY FROM THE EGRESS SIDE | | WHENEVER THE BUILDING IS OCCUPIED. LOCKS, IF PROVIDED, | | SHALL NOT REQUIRE THE USE OF A KEY, TOOL, OR SPECIAL | | KNOWLEDGE OR EFFORT FOR OPERATION FROM THE EGRESS | | SIDE.THE LOCK/LATCH RELEASING MECHANISM ON ALL DOORS | | SHALL OPEN THE DOOR WITH NOT MORE THAN ONE RELEASING | | OPERATION. THE RELEASING MECHANISM SHALL HAVE AN | | OBVIOUS METHOD OF OPERATION THAT IS READILY OPERATED | | UNDER ALL LIGHTING CONDITIONS. THE RELEASING DEVICE | | SHOULD BE CAPABLE OF BEING OPERATED WITH ONE HAND AND | | SHOULD NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR | | TWISTING OF THE WRIST TO OPERATE PER SECTION 7.2.1.5.9 | | OF NFPA 101 FLORIDA EDITION 2007. | | | | EVACUATION DIAGRAMS SHALL BE POSTED IN ASSEMBLY | | OCCUPANCIES. | | | | WESLEY JOLIN | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2012-12-08 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-12-08 |
Time |
19:28 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-12-08 |
Time |
19:15 |
Sent To |
|
|
Notes |
2012-12-08 19:28:04 | 4011 BROADWAY | | PERMIT #12120056 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | ALL OF THE CITY'S RECORDS INDICATE THE ADDRESS OF THIS | | BUSINESS AS 4013 BROADWAY. CORRECT PERMIT APPLICATION | | AND DRAWINGS. | | | | THE PLANS INDICATE THERE WILL BE NEW FRAMED OPENING | | INTO THE ADJACENT TENANT SPACE. WHAT PURPOSE DOES THIS | | OPENING SERVE? INDICATE THE OCCUPANCY TYPE AND OCCUPANT | | LOAD OF THE ADJACENT TENANT. | | | | THE PLANS INDICATE THIS SPACE IS AN EXISTING | | RESTAURANT; HOWEVER, NO KITCHEN AREA CAN BE LOCATED ON | | THE PLANS. | | | | PROVIDE A FURNITURE/SEATING LAYOUT. | | | | WESLEY JOLIN | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2013-02-15 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2013-02-15 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2013-01-30 |
Time |
09:23 |
Sent To |
|
|
Notes |
2013-01-31 09:23:39 | SENT TO B5 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-12-26 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-12-26 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-12-06 |
Time |
09:08 |
Sent To |
|
|
Notes |
2012-12-06 09:09:10 | INCOMING SENT TO B03 BOX. JW |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2013-02-11 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2013-02-11 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2013-02-11 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2012-12-12 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2012-12-12 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2012-12-12 |
Time |
13:44 |
Sent To |
|
|
Notes |
2012-12-12 13:49:54 | *** CORRECTIONS REQUIRED *** | | | | 1) PROVIDE FOR EXHAUST AIR IN BATHROOM, PER 2010 FBC/M | | 403.3 & TABLE 403.3. | | | | *** MECHANICAL PLAN REVIEW BY: TOM GORDON (HY-BYRD | | INC.) | | *** FOR ASSISTANCE CALL LUIS MARTINEZ (561) 805-6710 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2013-02-05 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-02-05 |
Time |
11:16 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-02-05 |
Time |
10:26 |
Sent To |
|
|
Notes |
2013-02-05 11:15:18 | FBC 2010 EXISTING BUILDING CODE | | FBC 2010 ACCESSIBILITY CODE | | FBC 2010 PLUMBING REVIEW #2 | | DENIED: | | | | 403.2 SEPARATE FACILITIES. | | WHERE PLUMBING FIXTURES ARE REQUIRED, SEPARATE | | FACILITIES SHALL BE PROVIDED FOR EACH SEX. | | EXCEPTIONS: | | 2. SEPARATE FACILITIES SHALL NOT BE REQUIRED FOR FOOD | | SERVICE ESTABLISHMENTS WHICH SEAT 10 PERSONS OR LESS. | | | | IF THE RESTROOM IN THE EXISTING KITCHEN IS TO BE | | COUNTED, THE ROUTE SHALL NOT BE THROUGH THE KITCHEN, | | STORAGE, ETC. | | 403.3.1 ACCESS. | | THE ROUTE TO THE PUBLIC TOILET FACILITIES REQUIRED BY | | SECTION 403.3 SHALL NOT PASS THROUGH KITCHENS, STORAGE | | ROOMS OR CLOSETS. ACCESS TO THE REQUIRED FACILITIES | | SHALL BE FROM WITHIN THE BUILDING OR FROM THE EXTERIOR | | OF THE BUILDING. ALL ROUTES SHALL COMPLY WITH THE | | ACCESSIBILITY REQUIREMENTS OF THE FLORIDA BUILDING | | CODE, ACCESSIBILITY. THE PUBLIC SHALL HAVE ACCESS TO | | THE REQUIRED TOILET FACILITIES AT ALL TIMES THAT THE | | BUILDING IS OCCUPIED. | | | | REVIEW BY | | LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | PHONE # 805-6692 | | EMAIL [email protected] | | FAX # 805-6676 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2012-12-10 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2012-12-10 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2012-12-10 |
Time |
14:38 |
Sent To |
|
|
Notes |
2012-12-10 15:23:18 | FBC 2010 EXISTING BUILDING CODE | | FBC 2010 ACCESSIBILITY CODE | | FBC 2010 PLUMBING REVIEW #1 | | DENIED: | | | | | | MORE INFORMATION WILL BE REQUIRED FOR A REVIEW. IS THIS | | A NEW RESTAURANT OR ADDITIONAL SPACE FOR AN EXISTING | | RESTAURANT? PLEASE INCLUDE THE OCCUPANCY TYPE, THE | | AMOUNT OF SEATS, AND OCCUPANCY LOAD. | | 403.2 SEPARATE FACILITIES. | | WHERE PLUMBING FIXTURES ARE REQUIRED, SEPARATE | | FACILITIES SHALL BE PROVIDED FOR EACH SEX. | | | | EXCEPTIONS: | | 2. SEPARATE FACILITIES SHALL NOT BE REQUIRED FOR FOOD | | SERVICE ESTABLISHMENTS WHICH SEAT 10 PERSONS OR LESS. | | | | REVIEW BY | | LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | PHONE # 805-6692 | | EMAIL [email protected] | | FAX # 805-6676 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2012-12-07 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2012-12-07 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2012-12-07 |
Time |
15:56 |
Sent To |
|
|
Notes |
|
|