Plan Review Details - Permit 12110752
Plan Review Stops For Permit 12110752
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-12-20 Cont ID  
Sent By JWITMER Date 2012-12-20 Time 15:38 Rev Time 0.00
Received By jwitmer Date 2012-12-20 Time 15:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-12-10 Cont ID  
Sent By jwitmer Date 2012-12-10 Time 13:14 Rev Time 0.00
Received By jwitmer Date 2012-12-10 Time 12:53 Sent To  
Notes
2012-12-10 13:14:14BUILDING PLAN REVIEW
 PERMIT: 12110752
 ADD: 429 45TH ST
 CONT: BCM CONSTRUCTION, INC
 TEL: (561)793-7543
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLEASE SUBMIT A SITE PLAN OR SURVEY PROVIDING THE
 SIZE OF THE TWO PROPOSED PARKING SPACES. INCLUDE IF
 THIS PROPERTY IS RESIDENTIAL OR IF THIS IS COMMERCIAL.
 IF COMMERCIAL THEN THE 2010 ACCESSIBILITY CODE WILL
 NEED TO BE ADHERRED TOO:
  
  
 2010 ACCESSIBILITY CODE.
 THE MINIMUM NUMBER OF HANDICAPPED PARKING SPACES FOR 2
 SPACES WOULD BE ONE, SEE TABLE 208.2.
  
 502.2 VEHICLE SPACES.
 EACH PARKING SPACE MUST BE AT LEAST 12 FEET (3658 MM)
 WIDE, SHALL BE MARKED TO DEFINE THE WIDTH, AND SHALL
 HAVE AN ADJACENT ACCESS AISLE COMPLYING WITH 502.3. SEE
 SECTION 406.5 CURB RAMP LOCATION.
  
 502.3 ACCESS AISLE.
 ACCESS AISLES SERVING PARKING SPACES SHALL COMPLY WITH
 502.3. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE.
 TWO PARKING SPACES SHALL BE PERMITTED TO SHARE A COMMON
 ACCESS AISLE.
  
 PARKING ACCESS AISLES MUST BE PART OF AN ACCESSIBLE
 ROUTE TO THE BUILDING OR FACILITY ENTRANCE. ACCESS
 AISLES MUST BE PLACED ADJACENT TO ACCESSIBLE PARKING
 SPACES. ALL SPACES MUST BE LOCATED ON AN ACCESSIBLE
 ROUTE THAT IS AT LEAST 44 INCHES (1118 MM) WIDE SO THAT
 USERS ARE NOT COMPELLED TO WALK OR WHEEL BEHIND PARKED
 VEHICLES EXCEPT BEHIND HIS OR HER OWN VEHICLE.
  
 406.5 LOCATION.
 CURB RAMPS AND THE FLARED SIDES OF CURB RAMPS SHALL BE
 LOCATED SO THAT THEY DO NOT PROJECT INTO VEHICULAR
 TRAFFIC LANES, PARKING SPACES, OR PARKING ACCESS
 AISLES. CURB RAMPS AT MARKED CROSSINGS SHALL BE WHOLLY
 CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED
 SIDES.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2013-01-04 Cont ID  
Sent By mgonzale Date 2013-01-04 Time   Rev Time 0.25
Received By mgonzale Date 2013-01-04 Time   Sent To I
Notes
2013-01-04 13:38:54NO CONFLICT WITH UTILITIES

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-01-07 Cont ID  
Sent By mdekle Date 2012-12-28 Time   Rev Time 0.00
Received By mdekle Date 2012-12-19 Time 09:44 Sent To  
Notes
2012-12-20 09:45:58RESUMITTAL CAME IN BEFORE ENGINEERING REVIEW WAS
 COMPLETED PLACED IN BIN C13.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-01-07 Cont ID  
Sent By mdekle Date 2012-12-10 Time   Rev Time 0.00
Received By mdekle Date 2012-11-30 Time 15:06 Sent To  
Notes
2012-12-03 15:07:47SENT TO C13 SHELF FOR REVIEW. JG.

Review Stop Z ZONING
Rev No 2 Status P Date 2012-12-28 Cont ID  
Sent By MDEKLE Date 2012-12-28 Time   Rev Time 0.00
Received By mdekle Date 2012-12-28 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2012-12-10 Cont ID  
Sent By mdekle Date 2012-12-10 Time   Rev Time  
Received By mdekle Date 2012-12-10 Time   Sent To  
Notes
2012-12-10 10:26:26ZONING PLAN REVIEW
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 1. THE APPLICANT MUST SUBMIT TWO COPIES OF A SITE PLAN
 DEPICTING THE PROPOSED LOCATION FOR THE PARKING SPACES.
 THE SITE PLAN MUST CONTAIN A PARKING STALL DETAIL WHICH
 DEMONSTRATES COMPLIANCE WITH THE STALL PAINTING DETAIL
 FOUND WITHIN CHAPTER 94-485; FIGURE XV-2 - GENERAL
 PARKING DIMENSIONS - OF THE CITY'S CODE
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME AND/OR
 CONSULT THE CITY?S ZONING AND LAND DEVELOPMENT
 REGULATIONS ONLINE @WWW.MUNICODE.COM.
  
 MURRIAH DEKLE, MPA
 PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
 WWW.CITYOFWPB.COM
  
2012-12-07 15:53:4312/10/12


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved