Plan Review Details - Permit 12110638
Plan Review Stops For Permit 12110638
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-12-27 Cont ID  
Sent By jwitmer Date 2012-12-27 Time 16:24 Rev Time 0.00
Received By jwitmer Date 2012-12-27 Time 15:13 Sent To  
Notes
2012-12-27 15:55:52I SPOKE WITH ARCHITECT DAVID MILLER ABOUT RED LINE LS
 AND A1.1 NEW DOOR SWING AS PER A1.0. JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-12-04 Cont ID  
Sent By jwitmer Date 2012-12-04 Time 15:46 Rev Time 0.00
Received By jwitmer Date 2012-12-04 Time 15:46 Sent To  
Notes
2012-12-04 16:02:26BUILDING PLAN REVIEW
 PERMIT: 12110638
 ADD: 319 CLEMATIS ST # 502
 CONT: CLAY KOHLMEYER
 TEL: (561)694-1214
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DEC. 04/2012
 ACTION: DENIED
  
 1) PLEASE REVIEW SHEET A-1.0 THE NEW EXECUTIVE BATHROOM
 DOOR AND ENTRY DOOR THERE IS LESS THAN 4'-0" BETWEEN
 DOORS, PLEASE SEE 2010 FBC ACCESSIBLITY CODE
 404.2.6 DOORS IN SERIES.
  
 2) CONFERENCE ROOM # 02 THE TENANT SEPERATION WALL IS
 MISSING A FIRE DAMPER IN ACCORDANCE WITH FBC-B 716.5.4.
 IT ALSO APPEARS THAT THE RESTROOM AND BREAKROOM EXHAUST
 AT THE TENANT SEPERATION WALL IS MISSING A FIRE DAMPER.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-01-02 Cont ID  
Sent By rlecky Date 2013-01-02 Time 09:13 Rev Time 0.00
Received By rlecky Date 2013-01-02 Time 09:02 Sent To  
Notes
2012-12-21 14:16:56REVISED SHEETS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-11-30 Cont ID  
Sent By rlecky Date 2012-11-30 Time 15:04 Rev Time 0.00
Received By rlecky Date 2012-11-30 Time 14:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2013-03-16 Cont ID  
Sent By wjolin Date 2013-03-16 Time 16:08 Rev Time 0.00
Received By wjolin Date 2013-03-16 Time 16:04 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2013-01-04 Cont ID  
Sent By wjolin Date 2013-01-04 Time 12:41 Rev Time 0.00
Received By wjolin Date 2013-01-04 Time 12:06 Sent To  
Notes
2013-01-04 12:36:56319 CLEMATIS STREET - SUITE #502
 PERMIT #12110638
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 REPEAT COMMENT - ELECTRICAL: NO ENGINEERED FIRE ALARM
 DRAWINGS SUBMITTED. PER FBC SECTION 907.1.1,
 CONSTRUCTION DOCUMENTS FOR FIRE ALARM SYSTEMS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE, THE
 FLORIDA FIRE PREVENTION CODE, AND RELEVANT LAWS,
 ORDINANCES, RULES AND REGULATIONS, AS DETERMINED BY THE
 BUILDING OFFICIAL.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-12-04 Cont ID  
Sent By wjolin Date 2012-12-04 Time 10:56 Rev Time 0.00
Received By wjolin Date 2012-12-04 Time 10:34 Sent To  
Notes
2012-12-04 10:56:51319 CLEMATIS STREET - SUITE #502
 PERMIT #12110638
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SHEET M2: NO EXISTING FIRE DAMPER SHOWN IN DUCTWORK
 PENETRATING CONFERENCE ROOM #2.
  
 ELECTRICAL: NO ENGINEERED FIRE ALARM DRAWINGS
 SUBMITTED.
  
 FIRE SPRINKLERS: FOR SYSTEM PRESSURES EXCEEDING 100
 PSI, ARMOVERS AND END OF BRANCH LINE PENDENT SPRINKLERS
 SHALL BE PROTECTED FROM UPWARD MOVEMENT. HANGERS SHALL
 BE LOCATED WITHIN 12-INCHES OF THE DROP ELBOW. INDICATE
 THE HANGER TYPE OR METHOD TO BE USED FOR RESTRAINING
 UPWARD MOVEMENT.
  
 SHEET FS2: PLAN INDICATES THIS IS FOR THE 7TH FLOOR
 (SHOULD BE 5TH FLOOR).
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-03-18 Cont ID  
Sent By lmartine Date 2013-03-16 Time 15:02 Rev Time 0.00
Received By lmartine Date 2013-03-11 Time 11:54 Sent To  
Notes
2013-03-12 11:54:46IN FIRE BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-01-04 Cont ID  
Sent By wjolin Date 2013-01-04 Time 12:42 Rev Time 0.00
Received By wjolin Date 2012-12-21 Time 14:15 Sent To  
Notes
2012-12-21 14:16:10SENT TO B9 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-12-06 Cont ID  
Sent By lwagner Date 2012-12-06 Time 10:04 Rev Time 0.00
Received By lwagner Date 2012-11-26 Time 09:47 Sent To  
Notes
2012-11-28 09:48:24B19

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-12-27 Cont ID  
Sent By tgordon Date 2012-12-27 Time 11:01 Rev Time 0.00
Received By tgordon Date 2012-12-27 Time 11:00 Sent To  
Notes
2012-12-27 11:18:55*** PROVISO ***
 1) SUBMIT AN UP TO DATE PRODUCT APPROVAL FOR THE NEW
 A/C CONDENSER STAND, FOR REVIEW BEFORE FINAL MECHANICAL
 INSPECTION. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS
 RULE 9N-3 NOV. 1, 2010, (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS: (G) EXTERIOR COOLER, FREEZERS &
 "PER-ENGINEERED A/C STANDS". ALSO SEE 2010 FBC
 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 2) CONDENSATE WATER FROM AHU-1 CAN NOT DISCHARGE INTO
 THE CITY WASTEWATER, PER CITY OF ORDINANCES CITY OF WPB
 CH.90 ARTICLE III SEC. 90-126. PROHIBITIONS AND
 LIMITATIONS OF DISCHARGE. (A) GENERALLY. USERS SHALL
 NOT DISCHARGE POLLUTANTS INTO THE WWF UNLESS IN
 ACCORDANCE WITH THIS ARTICLE. (B) DISCHARGE
 PROHIBITIONS. NO USER SHALL DISCHARGE INTO THE WWF ANY
 WASTE OR WASTEWATER WHICH MAY CAUSE PASS THROUGH OR
 INTERFERE WITH THE OPERATION OR PERFORMANCE OF THE WWF.
 NO USER SHALL DISCHARGE INTO THE WWF OR ANY CONNECTED
 SYSTEM ANY WASTE OR WASTEWATER CONTAINING ANY OF THE
 FOLLOWING: (5) STORM-WATER, SURFACE WATER, GROUNDWATER,
 ARTESIAN WELL WATER, ROOF RUNOFF, SUBSURFACE DRAINAGE,
 SWIMMING POOL DISCHARGES, UNCONTAMINATED COOLING WATER,
 UNPOLLUTED INDUSTRIAL PROCESS WATERS, AIR CONDITIONING
 CONDENSATE, UNLESS SPECIFICALLY AUTHORIZED BY THE CITY
 IN WRITING. SEE 2010 FBC/M 307.2.1.
 3) OFFICE 12 MAY NEED A R/A Z-BOOT, SEE 2010 FBC/M
 601.4.
 MECHANICAL PLAN REVIEW BY:
 TOM GORDON (HY-BYRD INC.) (561) 805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-12-04 Cont ID  
Sent By jwitmer Date 2012-12-04 Time 16:03 Rev Time 0.00
Received By jwitmer Date 2012-12-04 Time 16:03 Sent To  
Notes
2012-12-04 16:04:01MECHANICAL PLAN REVIEW
 PERMIT: 12110638
 ADD: 319 CLEMATIS ST # 502
 CONT: CLAY KOHLMEYER
 TEL: (561)694-1214
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DEC. 04/2012
 ACTION: DENIED
  
 1) CONFERENCE ROOM # 02 THE TENANT SEPERATION WALL IS
 MISSING A FIRE DAMPER IN ACCORDANCE WITH FBC-B 716.5.4.
 IT ALSO APPEARS THAT THE RESTROOM AND BREAKROOM EXHAUST
 AT THE TENANT SEPERATION WALL IS MISSING A FIRE DAMPER.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-05-01 Cont ID  
Sent By lwagner Date 2013-05-01 Time 15:18 Rev Time 0.00
Received By lwagner Date 2013-05-01 Time 15:18 Sent To  
Notes
2013-05-01 15:18:57RE-STAMP

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-12-06 Cont ID  
Sent By lwagner Date 2012-12-06 Time 10:03 Rev Time 0.00
Received By lwagner Date 2012-12-06 Time 09:17 Sent To  
Notes
***NONE***